General information
In the integrated electronics, the specified command value is compared with the position actual value. In case of control deviations, the stroke solenoid will be activated which - due to the changed magnetic force - adjusts the control spool against the spring.
Stroke/control cross-section is controlled proportionally to the command value. In case of a command value presetting of 0 V, the electronics adjusts the control spool against the spring to central position. In deactivated condition, the spring is untensioned to a maximum and the valve is in fail-safe position.
Switch-off behavior
With switched-off electronics, the valve will immediately move into the relevant secured basic position (fail-safe). In this connection, it moves through the position P–B/A–T which may result in movements at the controlled component. This has to be considered in the system design.
1 |
Control solenoid with position transducer |
2 |
Valve body |
3 |
Mating connector |
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
14 |
15 |
|||
4 |
WRP |
E |
H |
10 |
B |
‒ |
2X |
/ |
G24 |
K0 |
/ |
M |
* |
01 |
4 main ports |
4 |
02 |
High-response directional valve, direct operated |
WRP |
03 |
With integrated electronics |
E |
04 |
Control spool/sleeve |
H |
05 |
Size 10 |
10 |
06 |
Symbols; for the possible version, see "Symbols/Circuit diagrams" |
|
Installation side of the inductive position transducer |
||
07 |
Valve side B (standard) (see "Symbols/Circuit diagrams") |
B |
Rated flow at 70 bar valve pressure differential (35 bar/control edge) |
||
08 |
50 l/min |
50 |
100 l/min |
100 |
|
Flow characteristic |
||
09 |
Linear |
L |
Inflected characteristic curve |
P |
|
10 |
Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6 |
2X |
Supply voltage of the control electronics |
||
11 |
Direct voltage 24 V |
G24 |
Electrical connection |
||
12 |
Without mating connector; connector DIN 43563-AM6 Mating connectors, separate order |
K0 |
Control electronics interface |
||
13 |
Command value input ±10 V |
A1 |
Command value input 4 ... 20 mA |
F1 |
|
Seal material |
||
14 |
NBR seals, suitable for mineral oil HL and HLP according to DIN 51524 |
M |
15 |
Further details in the plain text |
* |
For applications outside these parameters, please consult us!
general
Type |
4WRPEH | |
Size |
10 | |
Component series |
2X | |
Design |
Directional spool valve, direct operated, with steel sleeve | |
Type of actuation |
Proportional solenoid with position control, OBE | |
Type of connection |
Plate connection, porting pattern according to ISO 4401 | |
Installation position |
Any | |
Weight |
kg |
7.1 |
Ambient temperature range |
°C |
-20 … +50 |
Maximum vibration resistance |
g |
25 |
hydraulic
Type |
4WRPEH | ||
Size |
10 | ||
Maximum operating pressure |
bar |
315 | |
Maximum operating pressure |
Port P |
bar |
315 |
Port A |
bar |
315 | |
Port B |
bar |
315 | |
Port T |
bar |
250 | |
Nominal flow |
l/min |
50 100 |
|
Hydraulic fluid temperature range |
°C |
-20 … +70 | |
Viscosity range |
Maximum admissible |
mm²/s |
10 … 800 |
Recommended |
mm²/s |
20 … 100 | |
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) |
Class 18/16/13 according to ISO 4406 (c) | ||
Hysteresis |
% |
≤ 0.2 | |
Manufacturing tolerance |
% |
< 10 | |
Actuating time |
Signal step 0 … 100% |
ms |
25 |
Temperature drift |
% |
< 1 |
1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
hydraulic
Nominal flow 1) |
l/min |
50 | 100 | 50 | 100 | |
Limitation of use |
Symbols C, C3, C5 |
bar |
315 | 160 | 315 | 160 |
Symbols C1, C4 |
bar |
250 | 100 | 250 | 100 | |
Zero flow |
Linear characteristic curve “L” |
l/min |
< 1.2 | < 1.5 | < 1.2 | < 1 |
Inflected characteristic curve "P" |
l/min |
< 0.05 | < 0.1 | < 0.05 | < 0.1 |
1) | With Δp = 35 bar/control edge |
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
Mineral oils and related hydrocarbons |
HL, HLP |
NBR / FKM |
DIN 51524 |
For more information and data on the use of other hydraulic fluids please contact us. |
electrical
Type |
4WRPEH | ||
Size |
10 | ||
Power supply |
Nominal voltage |
V |
24 |
Lower limit value |
V |
21 | |
Upper limit value |
V |
40 | |
Duty cycle |
% |
100 | |
Required fuse protection |
2.5 AF | ||
Maximum power consumption |
VA |
60 | |
Protection class according to DIN EN 60529 |
IP65 (with mating connector mounted and locked) | ||
EMC (electro-magnetic compatibility) |
CE conformity according to EMC directive 2004/108/EC tested according to EN 61000-6-2 and EN 61000-6-3 |
Fail-safe position
Fail-safe position |
|||||
C Flow at Δp = 35 bar per edge |
l/min |
50 |
50 |
100 |
100 |
C3, C5 |
cm3/min |
50 P-A |
|||
Zero flow at 100 bar |
cm3/min |
70 P-B |
|||
C3, C5 |
l/min |
10 ... 100 A-T |
|||
Flow at Δp = 35 bar per edge |
l/min |
10 ... 25 B-T |
|||
C4, C1 |
cm3/min |
50 P-A |
|||
Zero flow at 100 bar |
cm3/min |
70 P-B |
|||
cm3/min |
70 A-T |
||||
cm3/min |
50 B-T |
||||
Achievement of the fail-safe position |
0 bar |
12 ms |
|||
100 bar |
16 ms |
(measured with HLP46, ϑÖl = 40 ±5 °C)
Flow characteristics L: Linear 1:1
Flow characteristics L: Linear 2:1
Flow characteristics P: (Inflection 40%) 1:1
Flow characteristics P: (Inflection 40%) 2:1
Pressure amplification
Frequency response
Symbols
With control symbol C1 and C5, the following applies: |
|
P → A: qvmax |
B → T: qv/2 |
P → B: qv/2 |
A → T: qvmax |
Installation side of the inductive position transducer
Version A1: Standard
Version F1: mA signal
1 |
Control system |
2 |
On the customer side |
3 |
Mating connector |
4 |
Valve |
5 |
Connection surface |
6 |
On the Rexroth side |
Version |
Multi-wire cable |
Litz wire structure, finely stranded according to VDE 0295, class 6 |
|
Protective earthing conductor, green-yellow |
|
Cu shielding braid |
|
Type |
e.g. oilflex-FD 855 CP (Lappkabel) |
Number of wires |
Is determined by valve type, connector type and signal assignment |
Line diameter |
0,75 mm2 ... 20 m length |
External diameter |
9,4 ... 11,8 mm - Pg11 12,7 ... 13,5 mm - Pg16 |
Notice:
Supply voltage 24 VDCnom, if 18 VDC are undershot, there will be an internal fast shut-down, comparable to “Enable OFF”.
Additionally with version “F1”:
ID – E ≥ 3 mA – Valve is active
ID – E ≤ 2 mA – Valve is deactivated.
Electrical signals provided via control electronics (e. g. actual value) must not be used to switch off safety-relevant machine functions. (See also the European standard "Safety requirements for fluid-powered systems and their components - Hydraulics", EN 982!)
Block diagram / pin assignment version A1
Pin assignment 6P+PE; version "A1"
Block diagram / pin assignment version F1
Pin assignment 6P+PE; version "F1"
Dimensions in mm
1 |
Valve housing |
2 |
Integrated electronics (OBE) |
3 |
Identical seal rings for ports A, B, P and T (T1) |
4 |
Mating connector, separate order |
5 |
Control solenoid with position transducer |
6 |
Machined valve contact surface; Porting pattern according to ISO 4401-05-04-0-05 |
Subplates must be ordered separately |
Valve mounting screws (separate order):
4 hexagon socket head cap screws ISO 4762 - M6 x 40 - 10.9-N67F82170
Tightening torque MA = 11 + 3 Nm , material no. 2910151209
or
4 hexagon socket head cap screws ISO 4762 - M6 x 40 - 10.9
For valves with round connector
For valves with round connector
Service case with test unit for proportional servo valves with integrated electronics (OBE)
VT-VETSY-1-1X
Service case with test unit for proportional servo valves with integrated electronics (OBE)
VT-VETSY-1-1X
Component series 1XData sheet
Configurator / CAD
Spare parts & repair