General information

In the integrated electronics, the specified command value is compared with the position actual value. In case of control deviations, the stroke solenoid will be activated which - due to the changed magnetic force - adjusts the control spool against the spring.

Stroke/control cross-section is controlled proportionally to the command value. In case of a command value presetting of 0 V, the electronics adjusts the control spool against the spring to central position. In deactivated condition, the spring is untensioned to a maximum and the valve is in fail-safe position.

Switch-off behavior

With switched-off electronics, the valve will immediately move into the relevant secured basic position (fail-safe). In this connection, it moves through the position P–B/A–T which may result in movements at the controlled component. This has to be considered in the system design.

technical illustration-0811404803-

1

Control solenoid with position transducer

2

Valve body

3

Mating connector

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

4

WRP

E

H

10

B

2X

/

G24

K0

/

M

*

01

4 main ports

4

02

High-response directional valve, direct operated

WRP

03

With integrated electronics

E

04

Control spool/sleeve

H

05

Size 10

10

06

Symbols; for the possible version, see "Symbols/Circuit diagrams"

Installation side of the inductive position transducer

07

Valve side B (standard) (see "Symbols/Circuit diagrams")

B

Rated flow at 70 bar valve pressure differential (35 bar/control edge)

08

50 l/min

50

100 l/min

100

Flow characteristic

09

Linear

L

Inflected characteristic curve

P

10

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6

2X

Supply voltage of the control electronics

11

Direct voltage 24 V

G24

Electrical connection

12

Without mating connector; connector DIN 43563-AM6

Mating connectors, separate order

K0

Control electronics interface

13

Command value input ±10 V

A1

Command value input 4 ... 20 mA

F1

Seal material

14

NBR seals, suitable for mineral oil HL and HLP according to DIN 51524

M

15

Further details in the plain text

*

For applications outside these parameters, please consult us!

general

Type

4WRPEH

Size

10

Component series

2X

Design

Directional spool valve, direct operated, with steel sleeve

Type of actuation

Proportional solenoid with position control, OBE

Type of connection

Plate connection, porting pattern according to ISO 4401

Installation position

Any

Weight

kg

7.1

Ambient temperature range

°C

-20 … +50

Maximum vibration resistance

g

25

hydraulic

Type

4WRPEH

Size

10

Maximum operating pressure

bar

315

Maximum operating pressure

Port P

bar

315

Port A

bar

315

Port B

bar

315

Port T

bar

250

Nominal flow

l/min

50
100

Hydraulic fluid temperature range

°C

-20 … +70

Viscosity range

Maximum admissible

mm²/s

10 … 800

Recommended

mm²/s

20 … 100

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)

Class 18/16/13 according to ISO 4406 (c)

Hysteresis

%

≤ 0.2

Manufacturing tolerance

%

< 10

Actuating time

Signal step 0 … 100%

ms

25

Temperature drift

%

< 1
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

hydraulic

Nominal flow 1)

l/min

50 100 50 100

Limitation of use

Symbols C, C3, C5

bar

315 160 315 160

Symbols C1, C4

bar

250 100 250 100

Zero flow

Linear characteristic curve “L”

l/min

< 1.2 < 1.5 < 1.2 < 1

Inflected characteristic curve "P"

l/min

< 0.05 < 0.1 < 0.05 < 0.1
1) With Δp = 35 bar/control edge

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP

NBR / FKM

DIN 51524

For more information and data on the use of other hydraulic fluids please contact us.

electrical

Type

4WRPEH

Size

10

Power supply

Nominal voltage

V

24

Lower limit value

V

21

Upper limit value

V

40

Duty cycle

%

100

Required fuse protection

2.5 AF

Maximum power consumption

VA

60

Protection class according to DIN EN 60529

IP65 (with mating connector mounted and locked)

EMC (electro-magnetic compatibility)

CE conformity according to EMC directive 2004/108/EC tested according to EN 61000-6-2 and EN 61000-6-3

Fail-safe position

Fail-safe position

C

Flow at Δp = 35 bar per edge

l/min

50

50

100

100

C3, C5

cm3/min

50 P-A

Zero flow at 100 bar

cm3/min

70 P-B

C3, C5

l/min

10 ... 100 A-T

Flow at Δp = 35 bar per edge

l/min

10 ... 25 B-T

C4, C1

cm3/min

50 P-A

Zero flow at 100 bar

cm3/min

70 P-B

cm3/min

70 A-T

cm3/min

50 B-T

Achievement of the fail-safe position

0 bar

12 ms

100 bar

16 ms

(measured with HLP46, ϑÖl = 40 ±5 °C)

Flow characteristics L: Linear 1:1

technical illustration-0811404803-

Flow characteristics L: Linear 2:1

technical illustration-0811404803-

Flow characteristics P: (Inflection 40%) 1:1

technical illustration-0811404803-

Flow characteristics P: (Inflection 40%) 2:1

technical illustration-0811404803-

Pressure amplification

technical illustration-0811404803-technical illustration-0811404803-

Frequency response

technical illustration-0811404803-technical illustration-0811404803-technical illustration-0811404803-

Symbols

technical illustration-0811404803-

With control symbol C1 and C5, the following applies:

P → A: qvmax

B → T: qv/2

P → B: qv/2

A → T: qvmax

technical illustration-0811404803-

Installation side of the inductive position transducer

technical illustration-0811404803-

Version A1: Standard

technical illustration-0811404803-

Version F1: mA signal

technical illustration-0811404803-technical illustration-0811404803-

1

Control system

2

On the customer side

3

Mating connector

4

Valve

5

Connection surface

6

On the Rexroth side

Version

Multi-wire cable

Litz wire structure, finely stranded according to VDE 0295, class 6

Protective earthing conductor, green-yellow

Cu shielding braid

Type

e.g. oilflex-FD 855 CP (Lappkabel)

Number of wires

Is determined by valve type, connector type and signal assignment

Line diameter

0,75 mm2 ... 20 m length
1 mm2 ... 40 m length

External diameter

9,4 ... 11,8 mm - Pg11

12,7 ... 13,5 mm - Pg16

Notice:

Supply voltage 24 VDCnom, if 18 VDC are undershot, there will be an internal fast shut-down, comparable to “Enable OFF”.

Additionally with version “F1”:

ID – E ≥ 3 mA – Valve is active

ID – E ≤ 2 mA – Valve is deactivated.

Electrical signals provided via control electronics (e. g. actual value) must not be used to switch off safety-relevant machine functions. (See also the European standard "Safety requirements for fluid-powered systems and their components - Hydraulics", EN 982!)

Block diagram / pin assignment version A1

technical illustration-0811404803-

Pin assignment 6P+PE; version "A1"

technical illustration-0811404803-

Block diagram / pin assignment version F1

technical illustration-0811404803-

Pin assignment 6P+PE; version "F1"

technical illustration-0811404803-

Dimensions in mm

technical illustration-0811404803-

1

Valve housing

2

Integrated electronics (OBE)

3

Identical seal rings for ports A, B, P and T (T1)

4

Mating connector, separate order

5

Control solenoid with position transducer

6

Machined valve contact surface; Porting pattern according to ISO 4401-05-04-0-05
Deviating from the standard:
- Ports P, A, B, T and T1 with Ø10.5 mm

Subplates must be ordered separately

Valve mounting screws (separate order):

4 hexagon socket head cap screws ISO 4762 - M6 x 40 - 10.9-N67F82170

Tightening torque MA = 11 + 3 Nm , material no. 2910151209

or

4 hexagon socket head cap screws ISO 4762 - M6 x 40 - 10.9