BOSCH REXROTH
2FRM6A76-3X/32QRV
R900212869
Presure Compensated Flow Control Valves
Flow-/throttle valves: FRM 6.-3x/
BOSCH REXROTH
MATERIAL: R900212869
SUMMARY: Flow-/throttle valves: FRM 6.-3x/
Quantity in stock: 0
General information
The flow control valve type 2 FRM is a 2-way flow control valve.
It is used for maintaining a constant flow, independent of pressure and temperature.
The valve basically consists of housing (1), rotary knob (2), orifice bush (3), pressure compensator (4) and an optional check valve (8).
Flow control valve type 2FRM 6 A…RV
(with external closing, with check valve)
In principle, the function of this valve is the same as that of valve type 2FRM 6 B…MV.
However, the flow control valve is provided with the possibility of an external closing of the pressure compensator (4) via channel P (9). The external pressure acting in channel P (9) via orifice (10), holds the pressure compensator (4) in closed position against the compression spring (6). When the connected directional valve (11) is switched over to permit flow from P to B, control is achieved as with type 2FRM 6 B. Thus, a start-up jump is avoided.
The version with pressure compensator closing can only be used for supply control.
The free return flow from channel B to channel A is directed via the check valve (8).
Attention!
The pressure loss of port P upstream of the directional valve to port A upstream of the flow control valve makes itself felt by a reduced flow.
Type 2FRM 6 A76-3X/..RV
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
||
2FRM |
6 |
6 |
– |
3X |
/ |
V |
* |
01 |
2-way flow control valve |
2FRM |
02 |
Size 6 |
6 |
03 |
with closing of the pressure compensator (suppression of the start-up jump) |
A |
Adjustment type |
||
04 |
Lockable rotary knob with scale 1) |
3 |
Rotary knob with scale |
7 |
|
05 |
Zero position of the marking at port P |
6 |
06 |
Component series 30 ... 39 (30 ... 39: unchanged installation and connection dimensions) |
3X |
Flow (A → B) |
||
07 |
up to 0.2 l/min |
0,2Q |
up to 0.6 l/min |
0,6Q |
|
up to 1.5 l/min |
1,5Q |
|
up to 3.0 l/min |
3Q |
|
up to 6.0 l/min |
6Q |
|
up to 10 l/min |
10Q |
|
up to 16 l/min |
16Q |
|
up to 25.0 l/min |
25Q |
|
up to 32.0 l/min |
32Q |
|
08 |
With check valve |
R |
Without check valve |
M |
|
Seal material |
||
09 |
FKM seals (other seals upon request) |
V |
Observe compatibility of seals with hydraulic fluid used. |
||
10 |
Further details in the plain text |
* |
1) Key with material no. R900008158 is included in the scope of delivery. |
Preferred types and standard units are contained in the EPS (standard price list).
general
Size |
6 | |
Weight (approx.) |
kg |
1.3 |
Installation position |
any | |
Ambient temperature range |
°C |
-20 … +50 |
hydraulic
Size |
6 | ||||||||||
Maximum operating pressure 1) |
Anschluss A |
bar |
315 | ||||||||
Pressure differential Δp with free return flow B → A |
See characteristic curves | ||||||||||
Minimum pressure differential |
bar |
6 … 14 | |||||||||
Pressure stable (qV max) to Δp = 315 bar |
% |
± 2 | |||||||||
Maximum flow |
l/min |
0.2 | 0.6 | 1.5 | 3 | 6 | 10 | 16 | 25 | 32 | |
Minimum flow |
up to 100 bar |
l/min |
0.01 | 0.03 | 0.05 | 0.07 | 0.1 | 0.25 | |||
up to 315 bar |
l/min |
0.03 | 0.05 | 0.07 | 0.1 | 0.05 | |||||
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524, other hydraulic fluids on request | ||||||||||
Hydraulic fluid temperature range |
°C |
-20 … +80 | |||||||||
Viscosity range |
mm²/s |
10 … 800 | |||||||||
Maximum admissible degree of contamination of the hydraulic fluid 2) |
Class 20/18/15 according to ISO 4406 (c) |
1) | In applications with rectifier sandwich plate up to 210 bar |
2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
Flow dependent on the scale setting (flow control A → B)
Δp-qV characteristic curve via check valve (B → A) orifice closed
pE-qV characteristic curve
Temperature dependency at Δp = 20 bar
simplified |
Detailed |
|
without check valve; with external closing Type 2FRM 6 A…MV |
||
with check valve; with external closing Type 2FRM 6 A…RV |
Subplate mounting – version “A” and “B”
Dimensions in mm
1 |
Adjustment type "3" (lockable rotary knob with scale) |
2 |
Adjustment type "7" (rotary knob with scale) |
3 |
Identical seal rings for ports A, B, P, and T |
4 |
Space required to remove the key |
5 |
Bore Ø3 mm at version "B" not bored (without external closing) |
6 |
Name plate |
7 |
Position of the marking at port P |
8 |
Porting pattern according to DIN 24340 form A |
Subplate mounting:
Valve mounting screws (separate order)
without rectifier sandwich plate4 hexagon socket head cap screws
ISO 4762 - M5 x 30 - 10.9-flZn-240h-L
at friction coefficient μtotal = 0.09 to 0.14,
Tightening torque MA = 7 Nm ± 10 %,
Material no. R913000316
with rectifier sandwich plate4 hexagon socket head cap screws
ISO 4762 - M5 x 70 - 10.9-flZn-240h-L
at friction coefficient μtotal = 0.09 to 0.14,
Tightening torque MA = 7 Nm ± 10 %,
Material no. R913000325
Subplates (separate order)
Type G 341/01 (G1/4)
Type G 342/01 (G3/8)
Type G 502/01 (G1/2)