BOSCH REXROTH
F5P3-3X/0,2Q
R900452659
Flow Control Throttle Valves
Throttle valves: F 5-3X
BOSCH REXROTH
MATERIAL: R900452659
SUMMARY: Throttle valves: F 5-3X
Quantity in stock: 0
The flow control valve type F is a fine throttle valve with an orifice-type throttling point. It basically consists of housing (1), adjustment element (2) and orifice (3) and is used for throttling of a flow with low temperature dependency.
The flow from A to B is throttled at the orifice window (4). The throttle cross-section is set by rotation of the curved bolt (5). Low temperature dependency is achieved thanks to the orifice design of the throttling point.
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
||
F |
3 |
– |
/ |
* |
01 |
Fine throttle |
F |
||||
02 |
Size 5 |
5 |
||||
Size 10 |
10 |
|||||
03 |
for block installation |
K |
||||
For threaded connection |
G |
|||||
For subplate mounting |
P |
|||||
04 |
3 |
|||||
05 |
Component series 20 ... 29 (version "K") (20 ... 29: unchanged installation and connection dimensions) |
2X |
||||
Component series 30 ... 39 (version “G and “P”) (30 ... 39: unchanged installation and connection dimensions) |
3X |
|||||
06 |
NG25 |
Size 10 |
||||
progressive |
progressive |
Linear |
||||
Orifice 0.2 |
0,2Q |
Orifice 5 |
5Q |
Orifice 2 |
2L |
|
Orifice 0.6 |
0,6Q |
Orifice 10 |
10Q |
Orifice 5 |
5L |
|
Orifice 1.2 |
1,2Q |
Orifice 16 |
16Q |
Orifice 10 |
10L |
|
Orifice 3 |
3Q |
Orifice 25 |
25Q |
Orifice 16 |
16L |
|
Orifice 6 |
6Q |
Orifice 25 |
25L |
|||
Orifice 10 |
10Q |
Orifice 50 |
50L |
|||
Seal material |
||||||
07 |
NBR seals |
no code |
||||
FKM seals |
V |
|||||
Observe compatibility of seals with hydraulic fluid used. |
||||||
08 |
Further details in the plain text |
* |
general
Size |
5 | 10 | ||
Weight |
Block installation |
kg |
1 | |
Threaded connection |
kg |
1.6 | ||
Subplate mounting |
kg |
1.4 | ||
Installation position |
any | |||
Ambient temperature range |
NBR seals |
°C |
-30 … +80 | |
FKM seals |
°C |
-20 … +80 |
hydraulic
Size |
5 | 10 | ||
Maximum operating pressure |
bar |
210 | ||
Maximum flow |
l/min |
80 | ||
Hydraulic fluid |
see table | |||
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 | |
FKM seals |
°C |
-20 … +80 | ||
Viscosity range |
mm²/s |
2.8 … 380 | ||
Maximum admissible degree of contamination of the hydraulic fluid 1) |
Class 20/18/15 according to ISO 4406 (c) | |||
Adjustment angle |
° |
300 | ||
Actuating torque |
at 100 bar |
Nm |
1.1 | |
at 200 bar |
Nm |
1.8 |
1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
Mineral oil |
HL, HLP |
FKM, NBR |
DIN 51524 |
|
Bio-degradable |
Insoluble in water |
HEES (synthetic esters) |
FKM |
VDMA 24568 |
HETG (rape seed oil) |
FKM, NBR |
|||
Soluble in water |
HEPG (polyglycols) |
FKM |
VDMA 24568 |
|
Other hydraulic fluids on request |
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves: NG5
Δp-qV characteristic curves: NG5
Δp-qV characteristic curves: NG5
Δp-qV characteristic curves: NG5
Δp-qV characteristic curves: NG5
Δp-qV characteristic curves: NG5
Δp-qV characteristic curves: NG10 – linear
Δp-qV characteristic curves: NG10 – linear
Δp-qV characteristic curves: NG10 – linear
Δp-qV characteristic curves: NG10 – linear
Δp-qV characteristic curves: NG10 – linear
Δp-qV characteristic curves: NG10 – linear
Δp-qV characteristic curves: NG10 – progressive
Δp-qV characteristic curves: NG10 – progressive
Δp-qV characteristic curves: NG10 – progressive
Δp-qV characteristic curves: NG10 – progressive
Threaded port and subplate mounting
Dimensions in mm
NG |
H1 |
H2 |
H3 |
H4 |
H5 |
H6 |
H7 |
H8 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
5 | 56 | 42 | 95 | 122 | 26 | 30 | 12 | 10 |
10 | 58 | 42 | 97 | 124 | 22 | 27 | 14 | 10 |
Pipe thread "G" according to ISO 228/1
1 |
Rotary knob security lock (all positions can be locked), rotation range 300° corresponds to 10 scale sections |
2 |
Scaling |
3 |
Name plate |
4 |
Seal ring |
5 |
Blind plate (with threaded port only) |
6 |
Connection bores closed at version "P". |
Valve mounting screws (separate order)
4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9-flZn-240h-L
(friction coefficient μtotal = 0.09 to 0.14);
Tightening torque MA = 7 Nm ± 10 %,
Material no. R913000064
NG |
H1 |
H2 |
H3 |
H4 |
mm |
mm |
mm |
mm |
|
5 | 16 | 93 | 120 | 10.3 |
10 | 18 | 95 | 122 | 12.4 |
for block installation
Dimensions in mm
1 |
Rotary knob security lock (all positions can be locked), rotation range 300° corresponds to 10 scale sections |
2 |
Scaling |
3 |
Name plate |
4 |
Depth of fit |
5 |
Attention! Install port A and B outside the range of the mounting bores M5 – Risk of breaking! |
6 |
NG5: 4 hexagon socket head cap screws ISO 4762 - M5 x 16 - 10.9-flZn-240h-L (Friction coefficient μtotal = 0.09 to 0.14); Tightening torque MA = 7 Nm ± 10 % Material no. R913000468 |
NG10: 4 hexagon socket head cap screws ISO 4762 - M5 x 20 - 10.9-flZn-240h-L (Friction coefficient μtotal = 0.09 to 0.14); Tightening torque MA = 7 Nm ± 10 % Material no. R913000488 |
Dimensions in mm