Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
VT-DFPE-A-2X/G24K0/2A1E/V
R900724229
Proportional Directional Valves

VT-DFPE.-2X

$5,655.00

BOSCH REXROTH

MATERIAL:  R900724229

SUMMARY:  VT-DFPE.-2X

Add to Cart

01

02

03

04

05

06

07

08

09

10

11

VT-DFPE

-

-

2X

/

G24

K0

/

/

-

*

Series

01

Pilot valve with integrated analog electronics

VT-DFPE

Spool design

02

Standard (not for HFC fluids)

A

2-groove spool (only for replacement requirement)

B

4-groove spool (e.g. for HFC fluids)

C

03

Component series

2X

04

Direct voltage 24 V

G24

05

Connector (without mating connector) 1)

K0

Installation orientation connector (VT-DFP) and/or integrated electronics (see also comment on feature 6)

06

radially to the pump axis

0

folded 90° in the direction of the subplate with counterclockwise direction of rotation

1

folded 90° in the direction of the subplate with clockwise direction of rotation

2

Additional functions: Closed-loop control

A

B

C

D

R

07

Switchable pressure controller (high signal)

A

Power limitation adjustable at the OBE valve

B

Power limitation adjustable via analog input

C

Pressure controller that can be switched off (high signal)

D

Electronics assembly, option

08

Standard electronics with leakage oil compensation

-

-

0

Standard electronics without leakage oil compensation

1

Actual pressure value input
(For the description of the connectors refer to electrical connection)

Plug-in connector

09

Current input 4...20 mA

X1

C

Voltage input 0...10 V (standard)

X1

V

Voltage input 1...10 V

X1

E

Voltage input 0.5..5 V (Standard) 2)

X2

F

10

FKM seals suitable for mineral oils (HL, HLP) according to DIN 51524 and HFC fluids 3)

V

11

Further details in the plain text e. g. SO variant

*

available

-

not available

Note on feature 6: Installation orientation of the valve electronics

Clockwise direction of rotation, installation orientation 0

Clockwise direction of rotation, installation orientation 2

Counterclockwise direction of rotation, installation orientation 0

Counterclockwise direction of rotation, installation orientation 1

technical illustration-VT-DFPE-A-2X/G24K0/2A1E/V-VT-DFPE.-2X technical illustration-VT-DFPE-A-2X/G24K0/2A1E/V-VT-DFPE.-2X technical illustration-VT-DFPE-A-2X/G24K0/2A1E/V-VT-DFPE.-2X technical illustration-VT-DFPE-A-2X/G24K0/2A1E/V-VT-DFPE.-2X
1) Connector dependent on the valve type (see "Technical data" and "Electrical connection”).
2) With the SY(H)DFEn control system with analog interfaces, the plug-in connector X2 can not be used as actual pressure value input. Thus, a separate pressure transducer has to be used and connected to plug-in connector X1 in this case.
3) Only in connection with SYHDFE and spool design C (feature 2).
technical illustration-VT-DFPE-A-2X/G24K0/2A1E/V-VT-DFPE.-2X

1

Material number

2

Serial number

3

Date of production

4

Production order number

5

Type designation

Accessories

Version 10/2011, enquire availability

Accessories

Material number

Data sheet

Mating connector 12-pole for central connection X1 without cable (assembly kit)

R900884671

08006

Mating connector 12-pole for central connection X1 with cable set 2 x 5 m

R900032356

Mating connector 12-pole for central connection X1 with cable set 2 x 20 m

R900860399

Test device VT-PDFE-1-1X/V0/0 for SY(H)DFEE and SY(H)DFEC

R900757051

29689-B

Compact power supply unit VT-NE32-1X

R900080049

29929

Notice:

For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.

mechanic and hydraulic

Mass

Pump without through-drive incl. pilot valve

m

kg

2.25

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

mechanic and hydraulic

Weight without filling quantity

m

kg

2.25

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

electrical

Operating voltage

UB

24 VDC +40 % –5 %

Operating range (short-time operation)

Upper limit value

UB(t)max

V

35

Lower limit value

UB(t)min

V

21

Current consumption (in static control operation)

Rated current

Inom

A

0.6

Maximum current

Imax

A

1.25

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

Determination by means of ordering code

Analog current inputs, load

RB

100 Ω

Analog voltage inputs

RE

≥ 50 kΩ

Digital inputs

Logic 0

≤ 0,6 V

Logic 1

≥ 21 V

Outputs

pactual / UOUT1

UO

0 … 10 V

Imax

1,5 mA

αactual / UOUT2

UO

± 10 V

Imax

1,5 mA

Digital outputs

Logic 0

Ua < 1 V

Logic 1

Ua ≥ UB – 5 V; 10 mA (short-circuit-proof)

Ambient temperature range at the pump

ϑ

°C

​0 … +60

Storage temperature range (pump + electronics)

ϑ

°C

​0 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

mechanisch und hydraulisch

Weight without filling quantity

m

kg

2.25

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

elektrisch

Operating voltage

UB

24 VDC +40 % –5 %

Operating range (short-time operation)

Upper limit value

UB(t)max

V

35

Lower limit value

UB(t)min

V

21

Current consumption (in static control operation)

Rated current

Inom

A

0.6

Maximum current

Imax

A

1.25

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

Determination by means of ordering code

Analog current inputs, load

RB

100 Ω

Analog voltage inputs

RE

≥ 50 kΩ

Digital inputs

Logic 0

≤ 0,6 V

Logic 1

≥ 21 V

Outputs

nactual / UOUT1

UO

0 … 10 V

Imax

1,5 mA

αactual / UOUT2

UO

± 10 V

Imax

1,5 mA

Digital outputs

Logic 0

Ua < 1 V

Logic 1

Ua ≥ UB – 5 V; 10 mA (short-circuit-proof)

Ambient temperature range at the pump

ϑ

°C

​0 … +60

Storage temperature range (pump + electronics)

ϑ

°C

​0 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

elektrisch

Operating voltage

UB

24 VDC +40 % –5 %

Operating range (short-time operation)

Upper limit value

UB(t)max

V

35

Lower limit value

UB(t)min

V

21

Current consumption (in static control operation)

Rated current

Inom

A

0.6

Maximum current

Imax

A

1.25

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

Determination by means of ordering code

Analog current inputs, load

RB

100 Ω

Analog voltage inputs

RE

≥ 50 kΩ

Digital inputs

Logic 0

≤ 0,6 V

Logic 1

≥ 21 V

Outputs

pactual / UOUT1

UO

0 … 10 V

Imax

1,5 mA

αactual / UOUT2

UO

± 10 V

Imax

1,5 mA

Digital outputs

Logic 0

Ua < 1 V

Logic 1

Ua ≥ UB – 5 V; 10 mA (short-circuit-proof)

Ambient temperature range at the pump

ϑ

°C

​0 … +60

Storage temperature range (pump + electronics)

ϑ

°C

​0 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

mechanisch und hydraulisch

Mass

Pump without through-drive incl. pilot valve

m

kg

2.25

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

elektrisch

Operating voltage

UB

24 VDC +40 % –5 %

Operating range (short-time operation)

Upper limit value

UB(t)max

V

35

Lower limit value

UB(t)min

V

21

Current consumption (in static control operation)

Rated current

Inom

A

0.6

Maximum current

Imax

A

1.25

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

Determination by means of ordering code

Analog current inputs, load

RB

100 Ω

Analog voltage inputs

RE

≥ 50 kΩ

Digital inputs

Logic 0

≤ 0,6 V

Logic 1

≥ 21 V

Outputs

pactual / UOUT1

UO

0 … 10 V

Imax

1,5 mA

αactual / UOUT2

UO

± 10 V

Imax

1,5 mA

Digital outputs

Logic 0

Ua < 1 V

Logic 1

Ua ≥ UB – 5 V; 10 mA (short-circuit-proof)

Ambient temperature range at the pump

ϑ

°C

​0 … +60

Storage temperature range (pump + electronics)

ϑ

°C

​0 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

For applications outside these parameters, please consult us!

With integrated analog electronics

Allocation of connector or mating connector and cable set

With integrated analog electronics

Allocation of connector or mating connector and cable set

Functions at pin 9

Pin

Additional function

Function dependent on feature 7 of the ordering code (see type key)

Signal direction

Type of signal

9

-..A...

Selecting a different oil volume adjustment (switch TD)

IN

logic 24 V

-..B...

Power limitation active

OUT

logic 24 V

-..C...

Command value of power limitation

IN

analog 0...10 V

-..D...

Switch off pressure controller

IN

logic 24 V

1) When using a pressure transducer with raised zero point (e.g. 4...20 mA), a voltage of –1...–2.5 V will be output in case of a cable break.

X2: Connection of pressure transducer HM 16 (mating connector M12)

Pin

Signal HM 16

Pin

1

OUT, +UB

2

n.c.

2

Reference L0

3

IN, analog, 0.5 to 5 V DC

5

n.c.

Dimensions in mm

technical illustration-VT-DFPE-A-2X/G24K0/2A1E/V-VT-DFPE.-2X

Valve mounting screws for all types:

4 hexagon socket head cap screws

ISO4762-M6X40-10.9-flZn-240h-L,

friction coefficient μtotal = 0.09 to 0.14 according to VDA 235-101,

Tightening torque MA = 7 Nm,

material number: R913000058

1

Valve housing

2

Proportional solenoid with position transducer

3b

Mating connector for connector X1 (separate order see Accessories)

5

Identical seal rings for ports P, A, and T

6

Solenoid rotated by 90° (installation orientation "2")

7

Connection swivel angle position sensor (rotary angle sensor VT-SWA-1-1X)

8

Name plate

9

Integrated electronics

10

Mating connector X2 for connection of a pressure transducer HM 16

12

Space required for plug-in connection (HM 16)

13

Dimension for version VT-DFPE...F (connection for HM 16 or CAN bus)

Amending notes on the SY(H)DFE control systems can be found in the operating instructions (see section “Further information about this control system”).