VT-MSPA2-1-1X/V0/0
R901010980
Valve Amplifiers

Prop. valve ampl, modul 1X

$1,727.00

BOSCH REXROTH

MATERIAL:  R901010980

SUMMARY:  Prop. valve ampl, modul 1X

Add to Cart

You can either choose a single ramp (1 ramp time) or a 4-quadrant ramp (4 ramp times).

Characteristic curve generator [5]

Using the adjustable characteristic curve generator, step level and maximum values for positive and negative signals can be set separately, adjusted to the hydraulic requirements. The actual development of the characteristic curve through the zero point is not stepped but linear.

Amplitude limiter [6]

The internal command value is limited to approx. ±110 % of the nominal range.

Current controller [7]

The solenoid current is recorded, in the current controller compared with the control output and the difference is compensated.

Current output stage [8]

The current output stage creates the clocked solenoid current for the proportional valve. The solenoid current is limited to 2.7 A per output. The output stage outputs are short-circuit-proof. The output stages are de-energized in case of an internal fault signal or if the enable signal is missing.

Clock generator [9]

The clock generator creates the clock frequency "f" of the output stages. With pre-parameterized Rexroth valves, the frequency changes dependent on the command value and on the operating voltage.

Fault recognition [11]

The solenoid conductor is monitored for cable break as well as over-current of the output stage.

General

The amplifier modules are snapped onto top hat rails. The electrical connection is established via screw terminals. The modules are operated with 24 V direct voltage.

Power supply unit [1]

The amplifier modules have a power supply unit with making current limiter. This unit supplies all internally required positive and negative supply voltages. The making current limiter prevents high making current peaks.

Command value presetting

The internal command value signal is calculated from the total [3] of the external command value signal available at the differential input [2] and the zero point offset (zero point potentiometer "Zw").

A positive command value results in a current increase in solenoid “b” and thus a flow in the valve from P to A and from B to T.

A negative command value results in a current increase in solenoid “a” and thus a flow in the valve from P to B and from A to T.

Enable function [10]

Using the enable function, the power output stages are enabled and the internal command value signal is forwarded to the ramp generator. The enable signal is indicated by an LED on the front plate. If enable is connected, the internal command value is changed (with any kind of command value presetting) by the set ramp time. Thus, a controlled valve does not open abruptly.

Ramp generator [4]

The ramp generator limits the incline of the control output. The downstream step functions and amplitude attenuators do not extend or shorten the ramp time.

Notices for setting and measurement of the ramp time:

Value at measuring socket
"t <” or "t >"

U/V

5

3

2

1

0.5

0.3

0.2

0.1

0.05

0.03

0.02

Current ramp time (±20 %)

t/ms

20

33

50

100

200

333

500

1000

2000

3333

5000

01

02

03

04

05

VT-MSPA

2X

/

00

/

*

01

Valve amplifier for proportional valves without electrical position feedback, Analog, Modular design

VT-MSPA

02

1 solenoid

1

2 solenoids

2

03

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6

2X

04

Command value, voltage

A1

Command value, current

F2

05

Further details in the plain text

*

General

Component series

1X

Type of electronics

Analog

Design

Modul

Voltage supply

Operating voltage

nominal

U

V

24

Lower limit value

UB(t)min

V

18

Upper limit value

UB(t)max

V

35

Power consumption

max.

Smax

VA

48

Current consumption

max.

Imax

A

2

Fuse

Thermal overload protection (with restart if the value falls below the temperature threshold)

Analog inputs

Command value

Voltage (differential input)

U

V

​0 ... ±10

Voltage (differential input)

Input resistance

R

≥ 50

Digital inputs

Enable 1)

On (active)

U

V

8.5 ... UB

Enable

Off (inactive)

U

V

0 ... 6.5
1) RE > 100 kΩ

Solenoid outputs

Solenoid current

max.

Imax

A

2.5

Clock frequency 1)

command value-dependent

WRA6-2X

f

Hz

350 ... 240

Clock frequency 2)

command value-dependent

WRA10-2X

f

Hz

380 ... 180

Clock frequency 3)

Setting range

f

Hz

150 ... 400

Solenoid output

other properties

Short-circuit-proof, clocked

Cable length

for 1.5 mm2

L

m

50
1) With Ucommand = 0 V: 350 Hz
2) With Ucommand = 0 V: 380 Hz
3) Pre-set for valve 4WRPH6...-2X...-855

Adjustment options

Zero point calibration

%

± 30

Amplitude attenuator 1)

for command value

%

0 ... 110

Ramp time up/down

t

s

0.02 … 5

Step-change height

%

0 ... 50
1) Applies to a step level setting of 0%

Measuring sockets

Command value

"w"

U

V

0 ... ±10

after ramp

"wR"

U

V

0 ... ±10

Actual current value

"I"

U

V

0 ... ±2.5 (mV ≙ mA)

Ramp time

“down"

t

s

0.02 ... 5

“up"

t

s

0.02 ... 5

additional notices

See Function

Displays

LED display

Green

Ready for operation

yellow

Enable

Supplementary information

Anschlussart

12 screw terminals

Mounting type

Top hat rail TH 35-7.5 according to EN 60715

Type of protection according to EN 60529

IP 20

Ambient temperature range

ϑ

°C

​0 … ​50

Storage temperature range

ϑ

°C

-25 … ​70

Weight

m

kg

0.14

For applications outside these parameters, please consult us!

1

General application with Imax = 2.5 A; f = 150 Hz … 400 Hz

2

Clock frequency optimized for WRA 10

3

Clock frequency optimized for WRA 6

Gw+

Amplitude attenuator for positive command values

Gw-

Amplitude attenuator for negative command values

Sw+

Step level for positive direction

Sw-

Step level for negative direction

Zw

Zero point command value

t <

Ramp time "Ramp up"

t >

Ramp time "Ramp down"

f

Clock frequency

Measuring sockets

t <

Ramp time "Ramp up"

t >

Ramp time "Ramp down"

I

Actual current value (mV ≙ mA)

w

Command value

wR

Command value after ramp

Reference potential

LED displays

Ready for operation (green)

Enable (yellow)

technical illustration-VT-MSPA2-1-1X/V0/0-Prop. valve ampl, modul 1X

Power supply unit

Differential amplifier

Command value summation

Ramp generator

Characteristic curve generator

Amplitude limiter

Current controller

Power output stage

Clock generator

Enable

Fault recognition

Inverter

Zero point command value

Ramp time "Ramp up"

Ramp time "Ramp down"

Step-change height

Amplitude attenuator

Command value

Command value after ramp

Ready for operation (green)

Enable (yellow)

Rectifier sandwich plate

Dimensions in mm

technical illustration-VT-MSPA2-1-1X/V0/0-Prop. valve ampl, modul 1X

Dimensions in mm

technical illustration-VT-MSPA2-1-1X/V0/0-Prop. valve ampl, modul 1Xtechnical illustration-VT-MSPA2-1-1X/V0/0-Prop. valve ampl, modul 1X

The amplifier module may only be wired when de-energized.

Do not lay lines close to power cables.

Do not use free-wheeling diodes in the solenoid conductors.

The distance to aerial lines, radios, and radar systems has to be at least 1 m.

Always shield command value lines; connect shielding to protective earth (PE) on the module side.

Recommendation:
Also shield the solenoid conductors. For solenoid conductors up to a length of 50 m, use cable type LiYCY 1.5 mm2. For greater lengths, please contact us.

For switching command values, relays with gold-plated contacts have to be used (low voltages, low currents).

Only carry out measurements at the module using instruments with Ri > 100 kΩ.

For setting the potentiometers, use a screwdriver with a blade width of 4 mm.

With a strongly fluctuating operating voltage, it may in individual cases be necessary to use an external smoothing capacitor with a capacity of at least 2200 µF.

Recommendation: VT 11110 capacitor module (see data sheet 30750); sufficient for up to 3 amplifier modules

In the condition as supplied, the setting of the clock frequency corresponds to the requirements of the WRA 6 and

WRA 10 valves. Rotating the potentiometer “f” changes the valve hysteresis and may lead to disturbing noise developments.

Setting information

Preconditions: The system-specific circuitry must have been completed.

Zero point command value

Set the external command value presetting to zero

Set the internal command value to zero using the zero point potentiometer “Zw” and check the setting at measuring socket “wR”

Ramp times

Set ramp time according to formula or table (see functional description “Ramp generator”) and check it at the measuring sockets “t >” and “t <”.

Step level

Apply the enable signal

Use the zero point potentiometer "Zw” to set the measurement signal at "wR" to +0.3 V

Use potentiometer “Sw+” to set the required positive step level

Use the zero point potentiometer “Zw” to set the measurement signal at “wR” to –0.3 V

Use potentiometer “Sw-” to set the required negative step level

Set the zero point

Notice:

With external command value presetting, it must be at least +0.3 V / –0.3 V at measuring socket “wR”.

Maximum values

Notice:

Before adjusting the maximum values, zero point and step levels have to be set correctly.

The maximum current must not exceed the rated current of the solenoids.

Generate a command value ±100 % externally

Use potentiometer “Gw+/Gw-” to set the required maximum control output and check at measuring sockets “wR” and “w”

Clock frequency

Condition as supplied:

S = 1:      f = 170 Hz

S = 2 and “w” = 0:      f = 380 Hz

S = 3 and “w” = 0:      f = 350 Hz

The frequency can be reset using a digital multimeter which can measure frequencies. Measure at connection terminals 7 or 9 against 2 (ground).