Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
R901044401
Prefill Valves

Check valves: SF 200.-4x/

$32,520.00

BOSCH REXROTH

MATERIAL:  R901044401

SUMMARY:  Check valves: SF 200.-4x/

Add to Cart

Control port X: "Open" control port X1: "Close"

technical illustration-R901044401-Check valves: SF 200.-4x/

01

Prefill valves

SFS

02

Size

200

250

300

03

Flange connection

A

04

without pre-decompression

0

05

Main spool actively controllable

1

06

Component series 40 to 49 (40 to 49: unchanged installation and connection dimensions)

4X

Seal material

08

NBR seals

no code

Observe compatibility of seals with hydraulic fluid used.

09

Further details in the plain text

*

01

02

03

04

05

06

07

08

SFS

A

0

1

4X

/

*

general

Size

200 250 300

Weight

kg

190 380 655

Installation position

any

NG

Maximum switching time in ms 1)

Close

Open

ms

ms

200 60 70
250 70 80
300 110 90
1) At X, X1 = 150 bar. The switching time depends on the line resistance, control valve and pilot flow.

hydraulic

Size

200 250 300

Maximum operating pressure

Anschluss A

bar

16

Port B

bar

350

Anschluss X

bar

150

Anschluss X1

bar

150

Maximum flow

Case of application 1

l/min

5600 10000 14000

Case of application 2

l/min

4340 6775 9750

Case of application 3

l/min

3770 5890 8480

Case of application 4

l/min

1510 2360 3400

Druckflüssigkeit

Mineral oil (HL, HLP) to DIN 51524;fast bio-degradable hydraulic fluids according to VDMA 24568; HETG (rape seed oil); other hydraulic fluids on enquiry

Hydraulic fluid temperature range

°C

-30 … +80

Viscosity range

mm²/s

10 … 800

Maximum admissible degree of contamination of the hydraulic fluid 1)

Class 20/18/15 according to ISO 4406 (c)
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Flow ‒ case of application 1 (A to B)

technical illustration-R901044401-Check valves: SF 200.-4x/

Flow ‒ case of application 2 (A to B)

Size of the filling tank at least 1.5 x cylinder content

technical illustration-R901044401-Check valves: SF 200.-4x/

Flow ‒ case of application 3 (A to B)

technical illustration-R901044401-Check valves: SF 200.-4x/

Flow ‒ case of application 4 (A to B)

technical illustration-R901044401-Check valves: SF 200.-4x/

Information on case of application 1 to 4

For limit areas, please contact us. It is often enough, to select a pipeline which is one size larger.

technical illustration-R901044401-Check valves: SF 200.-4x/

Attention!

An underdimensioned prefill valve and/or an underdimensioned line leads to gas leaks from the hydraulic fluid with corresponding consequences and often to long-term damage at the cylinder seals.

1

Cylinders

2

Prefill valve

a

min. 300 mm with extended cylinder

b

up to 1000 mm with the specified maximum flows

c

≤ 500 mm

h

300 mm ≤ h < 500 mm

For applications outside these parameters, please consult us!

technical illustration-R901044401-Check valves: SF 200.-4x/

Dimensions in mm

technical illustration-R901044401-Check valves: SF 200.-4x/

1

Housing installation continuously rotatable by 360°

2

Flange according to EN 1092-1/11.../PN16

3

Name plate

T2

Depth of fit

N2

Number of the valve mounting screws evenly arranged at the circumference (separate order)

The following valve mounting screws are recommended:

Hexagon socket head cap screws ISO 21269 - 10.9

friction coefficient μtotal = 0.12 to 0.17

Number of the valve mounting screws evenly arranged at the circumference (separate order)

The following valve mounting screws are recommended:

Hexagon socket head cap screws ISO 21269 - 10.9

friction coefficient μtotal = 0.12 to 0.17

NG

Dimensions in mm

Tightening torqueMA in Nm

200

M36 x 3 x 150

3100

250

M42 x 3 x 180

5100

300

M42 x 3 x 220

5100

NG

B1

B2

B3

B4

ØD1

ØD2

ØD3

ØD4

ØD5

ØD6

ØD7

D8

D9

ØD10

ØD11

ØD12

ØD13

ØD14

ØD15

H1

H2

H3

H4

H5

N1

N2

T1

T2

T3

T4

R1

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

200 275 24 3 60 168 273 268 340 295 22 40 G1 1/4 350 420 290 350 M36 x 3 270 445 180 255 35 100 12 15 37 26 5 50 3
250 330 26 3 80 225 356 320 405 355 26 46 G1 1/2 G1 1/4 445 530 380 445 M42 x 3 355 571 240 320 55 120 12 18 57 42 8 60 5
300 380 28 4 94 250 419 378 460 410 26 46 G1 1/2 G1 1/4 525 610 450 525 M42 x 3 425 684 305 390 55 160 12 24 57 42 8 75 5

Poppet geometry and determination of the minimum pilot pressure

technical illustration-R901044401-Check valves: SF 200.-4x/

A1

Effective area of the main poppet

A2

Effective area of the control spool "closing"

A3

Effective area of the control spool "opening"

s

Piston stroke

V1

Pilot volume for opening the valve

V2

Pilot volume for closing the valve

pSt

Pilot pressure at port X

pB

Operating pressure at port B

technical illustration-R901044401-Check valves: SF 200.-4x/

NG

A1

A2

A3

s

V1

V2

Unchecking ratio

cm²

cm²

cm²

mm

cm³

cm³

200 216.4 36.4 50.3 42 211 153 4.3
250 373.3 67.4 95 52.5 503.7 353.8 3.9
300 572.6 92.86 143.1 63 901.8 585 4

Example: Type SFS 200 A0...

pB = 30 bar;

pSt = 4.3 x 30 bar = 129 bar