4WRA6E15-2X/G24XEJ/V
R901097419
Proportional Directional Valves

Prop. dir. valves: WRA,WRAE* 6.-2x/

$11,162.00

BOSCH REXROTH

MATERIAL:  R901097419

SUMMARY:  Prop. dir. valves: WRA,WRAE* 6.-2x/

Add to Cart

The 4/2 and 4/3 proportional directional valves are designed as direct operated valves in plate design. Operation is effected by means of proportional solenoids for potentially explosive areas. The solenoids are controlled by external control electronics.

Set-up:

The valve basically consists of:

Housing (1) with connection surface Control spool (2) with compression springs (3 and 4) Solenoids (5 and 6) with central thread

Functional description:

With de-energized solenoids (5 and 6), central position of the control spool (2) due to compression springs (3 and 4) Direct actuation of the control spool (2) by energization of one proportional solenoid, e. g. energization of solenoid "b" (6) Control spool (2) is moved to the left in proportion to the electrical input signal Connection from P → A and B → T via orifice-type cross-sections with progressive flow characteristics De-excitation of the solenoid (6) Control spool (2) is returned to the central position by the compression spring (3)

Notice:

With the 4/3 version of the valves, only one solenoid may be actuated at a time.

Type 4WRA 6 ...XE

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Valve with 2 spool positions (type 4WRA 6 .A...XEJ...):

The function of this valve version basically corresponds to the valve with three spool positions. The 2 spool position valves are, however, only equipped with solenoid "a" (5). Instead of the 2nd proportional solenoid, a plug screw (7) is installed.

Notice:

The tank line must not be allowed to run empty. With corresponding installation conditions, a preload valve (preload pressure approx. 2 bar) must be installed.

01

02

03

04

05

06

07

08

09

10

11

4

WRA

6

2X

/

G24

XE

J

/

*

01

4 main ports

4

02

Proportional directional valve for external control electronics

WRA

03

Size 6

6

04

Symbols; for the possible version, see "Symbols/Circuit diagrams"

E;E1-;W;W1-;EA;WA

Nominal flow

05

6 l/min

07

10 l/min

15

18 l/min

30

06

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions)

2X

Supply voltage of the control electronics

07

Direct voltage 24 V

G24

Explosion protection

08

“Increased safety” explosion protection; for details, please refer to the information on explosion protection

XE

Surface protection

09

Seawater-resistant, galvanized

J

Seal material

10

NBR seals

M 1)

FKM seals

 

V

Observe compatibility of seals with hydraulic fluid used.

11

Further details in the plain text

*

1) Suitable for mineral oils (HL, HLP) according to DIN 51524

general

Type

4WRA

Size

6

Installation position

any, preferably horizontal

Ambient temperature range

°C

-20 … +60

Storage temperature range

°C

+5 … +40

Maximum storage time 1)

yrs

1

Weight

4WRA 6...XE

kg

4.4

4WRA 6...A...XE

kg

2.7

Surface protection

Galvanized
1) see operating instructions 29055-XE-B

hydraulic

Size

6

Maximum operating pressure

bar

315

Maximum operating pressure

Port P

bar

315

Port T

bar

210

Port A

bar

315

Port B

bar

315

Maximum flow

l/min

22

Nominal flow

l/min

6
10
18

Hydraulic fluid

see table

Hydraulic fluid temperature range

NBR seals

°C

-20 … +80

FKM seals

°C

-15 … +80

Viscosity range

mm²/s

20 … 380

preferably

mm²/s

30 … 46

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)

Class 17/15/12

Hysteresis

%

≤ 6

Range of inversion

%

≤ 2

Response sensitivity

%

≤ 1

Maximum surface temperature

°C

120
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Data sheet

Mineral oils

HL, HLP, HLPD, HVLP, HVLPD

NBR, FKM

DIN 51524

90220

Bio-degradable

1)

Insoluble in water

HETG

FKM

ISO 15380

90221

HEES

FKM

Soluble in water

HEPG

FKM

ISO 15380

Flame-resistant

1)

Water-free

HFDU, HFDR

FKM

ISO 12922

90222

Containing water

HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620 )

NBR

ISO 12922

90223

Important information on hydraulic fluids:

For further information and data on the use of other hydraulic fluids, please refer to the data sheets above or contact us. There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.). The ignition temperature of the hydraulic fluid used must be 50 K higher than the maximum solenoid surface temperature.

Flame-resistant – containing water:

Maximum operating pressure 210 bar Maximum pressure differential per control edge 175 bar Pressure pre-loading at the tank port > 20% of the pressure differential, otherwise increased cavitation erosion Life cycle as compared to operation with mineral oil HL, HLP 50 … 100% Maximum hydraulic fluid temperature 50 °C

Bio-degradable and flame-resistant: If these hydraulic fluids are used which are also zinc-solving, an accumulation of zinc may occur.

1) Not recommended for corrosion-protected version "J"

electrical

Size

6

Voltage type

Direct current or pulse-width modulated signal with a pulse voltage ≤ 28 V and a frequency ≥ 160 Hz up to max. 500 Hz

Type of signal

analog

Maximum solenoid current

A

1.03

Actuated time

%

100

Maximum coil temperature

°C

120

Control electronics

Amplifier module for the control of explosion-proof proportional directional valves 4WRA...XE, 3DREP 6...XE and 4WRZ...XE

VT-MSPA2-200-1X/V0/0 according to data sheet 30228-200

Module for monitoring and limiting the solenoid currents with proportional valves

VT-MUXA2-2-1X/V0/1A according to data sheet 30290

Notice:
For monitoring the solenoid current, a monitoring circuitry is to be provided. We recommend operating the valves with the assemblies described herein.

Information on explosion protection

Application according to Explosion Protection Directive 2014/34/EU

II 2G

Type of protection of the valve according to EN 13463-1/ EN 13463-5

c T4 X

Valve solenoid type of protection according to EN 60079-7 / EN 60079-18 1)

Ex e mb IIC T4 Gb

Type examination certificate solenoid

KEMA 02ATEX2240 X

“IECEx Certificate of Conformity” for solenoid

IECEx DEK 12.0068X

Special application conditions for a safe application

– In case of bank assembly, only one solenoid of all valves may be energized at a time.
‒ In case of valves with two solenoids, only one of the solenoids may be energized at a time.
‒ Only direct current or a pulse-width modulated signal with a pulse voltage ≤ 28 V and frequency ≥ 160 Hz up to max. 500 Hz may be used.
1) Surface temperature > 50 °C, provide contact protection.

(measured with HLP46, ϑÖl = 40 ±5 °C)

Ordering code 07: 6 l/min at a valve pressure differential of 10 bar

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Ordering code 15: 10 l/min at a valve pressure differential of 10 bar

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Ordering code 30: 18 l/min at a valve pressure differential of 10 bar

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Performance limit rated flow 6 l/min

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Performance limit rated flow 10 l/min

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Performance limit rated flow 18 l/min

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Transition function with stepped electric input signals

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/
technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

With control spool symbol E1- and W1-, the following applies:

P → A: qvmax

B → T: qv/2

P → B: qv/2

A → T: qvmax

At symbols W, W1 and WA, there is a connection of A → T and B → T in zero position with approx. 3 % of the respective nominal cross-section.

Notice:

Representation according to DIN ISO 1219-1. Hydraulic interim positions are shown by dashes.

The type-examination tested valve solenoid is equipped with a terminal box and a type-tested cable gland. The connection is polarity-independent.

Notice:

Corresponding to the rated current, a fuse according to DIN 41571 and EN / IEC 60127 has to be connected upstream of every valve solenoid (max. 3 x Irated).

The shut-off threshold of the fuse has to match the prospective short-circuit current of the supply source.

The prospective short-circuit current of the supply source may amount to a maximum of 1500 A.

This fuse may only be installed outside the potentially explosive area or must be of an explosion-proof design.

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/
1) Recommended pre-fusecharacteristics:
medium time-lag according to DIN 41571; 1.25 A

Properties of the connection terminals and mounting elements

Position

Function

Connectable line cross-section

1

Operating voltage connection

Single-wire 0.75 … 2.5 mm2

Finely stranded,0.75 … 1.5 mm2

2

Connection for protective earthing conductor

Single-wire 2.5 mm2 max.

Finely stranded, 1.5 mm2 max.

3

Connection for potential equalization conductor

Single-wired, 4 … 6 mm2

Finely stranded, 4 mm2

Cable gland

Type approval

II 2G Ex e IIC Gb

Threaded connection

M20 x 1,5

Protection class according to DIN EN 60529

IP66 (with correctly installed electrical connection)

Line diameter

7 … 10,5 mm

Sealing

Outer sheath sealing

Connection line

Line type

Non-armored cables and lines (outer sheath sealing)

Temperature range

–30 … > +110 °C

Dimensions in mm

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/
technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Required surface quality of the valve contact surface

1

Valve housing

2

Proportional solenoid "a"

3

Proportional solenoid "b"

4

Terminal box

5

Name plate

6

Identical seal rings for ports A, B, P, and T

7

Plug screw for valves with one solenoid (2 spool positions, version "EA" or "WA")

8

Porting pattern according to ISO 4401-03-02-0-05 (but without locating hole)

Valve mounting screws (separate order):

For reasons of stability, exclusively the following valve mounting screws are to be used:

4 hexagon socket head cap screws ISO 4762-M5x50-10.9-flZn-240h-L

(friction coefficient 0.09 – 0.14 according to VDA 235-101)

Tightening torque MA = 7 Nm ±10%,

Material no. R913000064

 

Subplates (separate order) with porting pattern according to ISO 4401-03-02-0-05, see data sheet 45100.

Installation conditions (dimensions in mm)

Single assembly

Bank assembly

Subplate dimensions

Minimum dimensions:
Length ≥ 64, width ≥ 58, height ≥ 25

Minimum cross-section:
Height ≥ 60, width ≥ 85

Thermal conductivity of the subplate (EN-GJS-500-7)

≥ 38 W/mK

Minimum distance between the longitudinal valve axes

≥ 55 mm

Schematic diagram

Dimensions in mm

technical illustration-4WRA6E15-2X/G24XEJ/V-Prop. dir. valves: WRA,WRAE*  6.-2x/

Notice:

In case of bank assembly, only one solenoid of all valves may be energized at a time.