Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
HEDE11A1-1X/400/K41G24/2/V
R901141188
Pressure Switches

Switch HEDE11.1X/

$749.00

BOSCH REXROTH

MATERIAL:  R901141188

SUMMARY:  Switch HEDE11.1X/

Add to Cart

01

02

03

04

05

06

07

08

09

10

11

HED

E

11

A1

1X

/

/

K41

G24

/

2

/

V

/

*

01

Hydraulic/electric pressure switch

HED

02

Integral electronics

E

03

Device type

11

04

Interface hydraulic G1/4

A1

05

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

Pressure rating

06

100 bar

100

250 bar

250

400 bar

400

Electrical connection

07

Connector M12, 4-pole as standard, without mating connector

K41

Power supply

08

Direct voltage 24 V

G24

Electrical interface

09

2 switching outputs

2

Seal material

10

FKM seals

V

Observe compatibility of seals with hydraulic fluid used.

11

Further details in the plain text

Type

Material number

HEDE11A1-1X/100/K41G24/2/V

R901141184

HEDE11A1-1X/250/K41G24/2/V

R901396832

HEDE11A1-1X/400/K41G24/2/V

R901141188

Type

Component series

1X

General

Weight

m

kg

0.09

Installation position

any

Ambient temperature range

ϑ

°C

-20 … +80

Storage temperature range

ϑ

°C

-40 … +100

Hydraulisch

Pressure measuring ranges

pN

bar

100 250 400 100 250 400 100 250 400

Switching point

Setting range

bar

5 12.5 20 5 12.5 20 5 12.5 20

Reset range

bar

3 7.5 12 3 7.5 12 3 7.5 12

Hydraulic fluid temperature range

ϑ

°C

-25 … ​80 -25 … +80 -25 … ​80 -25 … +80 -25 … ​80 -25 … +80

Materials in contact with the medium

V4A (1.4404), FKM

Electric

Operating voltage

UB

18 … 36 VDC

Current consumption

I

mA

< 25

Short-circuit protection

clocked

Overload resistance

yes

Reverse polarity protection

yes

Voltage drop

U

V

< 2

Switching frequency

f

Hz

100

Accuracy class 1)

%

< 2.5

Repetition accuracy 1)

< 0.5 %

Switching cycles, minimum

50 million

Protection class according to DIN EN 60529

IP67

Isolation resistance

R

> 100 (500 VDC)

Electro-magnetic compatibility

EMC EN 61000-4-2 ESD

4 kV CD / 8 kV AD

EMC EN 61000-4-3 HF radiated

10 V/m

EMC EN 61000-4-4 Burst

2 kV

EMC EN 61000-4-6 HF line-bound

10 V

UL approval

UL 508
1) of the measurement range end value

In order to satisfy the “limited voltage current” requirements according to UL, the device must be supplied from a galvanically separated source and a overcurrent protection has to be provided.

For applications outside these parameters, please consult us!

The electronic pressure switch records the system pressure and switches the both outputs OUT1 (pin 4) / OUT2 (pin 2) in an antivalent manner.

In case of increasing pressure, OUT1 closes / OUT2 opens if the set SET value is reached. In case of decreasing pressure, OUT1 opens / OUT2 closes if the set RESET value is reached. technical illustration-HEDE11A1-1X/400/K41G24/2/V-Switch HEDE11.1X/

Wire colors with Bosch Rexroth mating connectors

1

BN (brown)

2

WH (white)

3

BU (blue)

4

BK (black)

technical illustration-HEDE11A1-1X/400/K41G24/2/V-Switch HEDE11.1X/

Setting information:

Minimum distance Set – Reset = 2 % of the measurement range end value In order to comply with the setting accuracy: Set both rings to the lower stop value first, then to the desired values.

Dimensions in mm

technical illustration-HEDE11A1-1X/400/K41G24/2/V-Switch HEDE11.1X/