Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
HED5OH-3X/350K14
R901186323
Pressure Switches

Switch HED5.3X/

$333.00

BOSCH REXROTH

MATERIAL:  R901186323

SUMMARY:  Switch HED5.3X/

Add to Cart

Hydro-electric pressure switches of type HED 5 are piston type pressure switches.

They basically consist of housing (1), installation kit with piston (2), compression spring (3), adjustment element (4) and micro switch (5)

The pressure to be monitored acts on the piston (2)

The latter is supported by the spring plate (6) and acts against the continuously adjustable force of the compression spring (3).

The spring plate (6) transmits the movement of the piston (2) onto the micro switch (5). This switches the electric circuit on or off, depending on the circuit set-up.

Notice:

In order to increase the life cycle, the pressure switch should be mounted with low vibrations and protected from hydraulic pressure surges.

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

01

Piston type pressure switch

HED5

02

Flange connection

OH

03

Component series 30 ... 39 (version “G and “P”) (30 ... 39: unchanged installation and connection dimensions)

3X

04

Pressure rating maximum 50 bar

50

Pressure rating maximum 100 bar

100

Pressure rating maximum 200 bar

200

Pressure rating maximum 350 bar

350

Electrical connection

05

Individual connection

Without mating connector; connector DIN EN 175301-803

K14 1)

Seal material

07

NBR seals

no code

FKM seals

V

Low-temperature seals (max. 315 bar)

MT

Observe compatibility of seals with hydraulic fluid used. (Other seals upon request)

08

Further details in the plain text

1) Mating connectors, separate order, see accessories

Type

Component series

3X

General

Weight

m

kg

0.2

Installation position

any

Ambient temperature ranges (NBR seals)

ϑ

°C

-30 … +50

Ambient temperature ranges (FKM seals)

ϑ

°C

-20 … +50

Ambient temperature range (low-temperature seal)

ϑ

°C

-40 … +50

Sine test

DIN EN 60068-2-6:1996-05, 10...2000 Hz, max. 10 g, 10 double cycles

Transport shock

DIN EN 60068-2-27:1995-03, half-sine 15 g / 11 ms, 3 x in positive direction, 3 x in negative direction (a total of 6 single shocks per axis)

Noise test

DIN EN 60068-2-64: 1995-08, 20...2000 Hz, 14gRMS, 24 h

Conformity/certification

CE

DIN EN 61058-1: 2002 / A2: 2008
DIN EN 60947-1: 2007 / A1: 2011
DIN EN 60947-5-1: 2004 / A1: 2009
DIN EN 60529: 1991 / A2: 2013

UL

UL, 508 17th edition File No E223220 (up to 350 bar)

CCC

GB 14048.5-2008

Hydraulisch

Pressure rating

p

bar

50 100 200 350

Operating pressure NBR/FKM seals, max.

p

bar

350 400

Pressure adjustment range (decreasing)

p

bar

5 … 50 10 … 100 15 … 200 25 … 350

Pressure differential per rotation 1)

p

bar

≈ 10 ≈ 17 ≈ 38 ≈ 60

Hydraulic fluid 1)

see table below

Hydraulic fluid temperature range (NBR seals)

ϑ

°C

-30 … +80

Hydraulic fluid temperature range (FKM seals)

ϑ

°C

-20 … +80

Hydraulic fluid temperature range (low-temperature seals)

ϑ

°C

-40 … +80

Viscosity range

μ

mm²/s

10 … 800

Maximum admissible degree of contamination of the hydraulic fluid 2)

Class 20/18/15 according to ISO 4406 (c)

Load cycles

≥ 4 million
1) Direction of rotation:
clockwise → Set pressure increase
counterclockwise → Set pressure decrease
2) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP

NBR, FKM

DIN 51524

HVLP

Low-temperature design MT

Bio-degradable

Insoluble in water

HETG

NBR, FKM

ISO 15380

HEES

FKM

Soluble in water

HEPG

FKM

ISO 15380

Flame-resistant

Containing water

HFC

NBR

ISO 12922

Important information on hydraulic fluids!

Further information and information on the use of other hydraulic fluids on request!

Elektrisch

Anschlussart

EN 175301-803, 3-pole + PE

Protection class according to DIN EN 60529

IP65 with mating connector mounted and fitted

Line cross-section

Mating connector, max.

mm²

1.5

Line entry mating connector

M16 x 1.5

Switching frequency, max.

1/h

4800

Switching accuracy (repetition accuracy)

< 1 % of the set pressure

Switch

according to VDE 0630-1/DIN EN 61058-1

Transition resistance

R

< 50

Insulation coordination

Überspannung Kategorie 3

Contamination

Degree of contamination 3

Bounce time

On

t

ms

< 5

Off

t

ms

< 5

Current, min. 1)

I

mA

1.0 with 24 V DC

Current, max.

I

A

0.5 with 50 V DC, inductive

I

A

0.2 with 125 V DC, inductive

I

A

0.1 with 250 V DC, inductive

I

A

2.0 with 250 V AC
1) DC-12 (utility model according to IEC 60947)
2) DC-22 (utility model according to IEC 60947)
3) AC-12 (utility model according to IEC 60947)

Switching power

Switching cycles

Voltage U in V

Ohmic load max. in A

Inductive load, max. in A

2 million

250, AC

2 A for 2 million switching cycles (AC-12)

0.5 A, cos. ϕ = 0.6 for 2 million switching cycles (DC-12)

2 million

24, DC

2 A for 2 million switching cycles (AC-12)

0.5 A for 2 million switching cycles 3)

5 million

24, DC

5.0 mA for 5 million switching cycles (DC-12)

3)​

Value does not comply with any utility category according to IEC 60947

All variants can be unloaded to pmin = 0 bar. (Observe the switching pressure differential!)

For applications outside these parameters, please consult us!

Switching pressure differential (measured with HLP46, ϑOil = 40 ±5 °C)

Pressure rating 50 bar

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Pressure rating 100 bar

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Pressure rating 200 bar

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Pressure rating 350 bar

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Notice:

The switching pressure differential may increase within the course of the life cycle due to the deterioration of the oil quality and the number of load cycles.

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

"K14" without indicator light

"K14" with indicator light

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/ technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Switching function

Terminals 1-2: Contact opens in case of pressure increase

Terminals 1-3: Contact closes in case of pressure increase

Notice:

For general information on safety, installation or commissioning, see operating instructions.

Type HED 5 …K14

Dimensions in mm

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

1

Adjustment element

2

Plug-in connection according to EN 175301-803 (port “K14”)

3

Mating connector without circuitry (separate order)

4

Mating connector with circuitry (separate order)

5

Space required to remove the mating connector

6

Seal ring (connection bore of the counterpart: max. Ø6)

Mounting screws (separate order)

4 hexagon socket head cap screws ISO 4762-M4X45-10.9-flZn-240h-L

(friction coefficient μtotal = 0.09 to 0.14)

Tightening torque MA = 2 Nm ± 10 %

Material no. R913000370

Mating connectors for mechanical pressure switches with connector “K14”, without circuitry, standard

4P Z14

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Mating connectors for mechanical pressure switches with connector “K14”, without circuitry, standard

4P Z14

For mechanical pressure switches with connector “K14”, according to EN 175301-803 and ISO 4400, 3-pole + PE, “large cubic connector”

Data sheet

Spare parts & repair

Mating connectors for mechanical pressure switches with connector “K14”, with indicator lights at connections 2 and 3

4P Z15L

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Mating connectors for mechanical pressure switches with connector “K14”, with indicator lights at connections 2 and 3

4P Z15L

For mechanical pressure switches with connector “K14”, according to EN 175301-803 and ISO 4400, 3-pole + PE, “large cubic connector”

Data sheet

Spare parts & repair

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1

4P Z24

technical illustration-HED5OH-3X/350K14-Switch HED5.3X/

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1

4P Z24

For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75 mm2

Data sheet

Spare parts & repair