Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
VT-MUXA2-2-1X/V0/1A
R901254583
Valve Amplifiers

Comand value technic, analog, modul 1X

$3,007.00

BOSCH REXROTH

MATERIAL:  R901254583

SUMMARY:  Comand value technic, analog, modul 1X

Add to Cart

Use

The VT-MUXA2-2 module can be used to monitor 1 or 2 solenoid circuits. The solenoid currents are limited so that there is no overheating of the solenoids. The solenoid currents necessary for operating the valve are provided by an amplifier (order separately).

The amplifier is adjusted according to the rated current data of the solenoid (rated current = 1.03 A). With a command value presetting of 10 V, it provides an output current of 1.0 A.

In case of defect or incorrect operation, the amplifier may provide a current of more than 1.0 A. The interconnected VT-MUXA2-2 monitoring module recognizes the over-current, reduces the command value or switches off the solenoid current.

The VT-MUXA2-2 monitoring module must be protected against voltage peaks from the 24 V mains. Our VT 11110 capacitor module protects against voltage peaks and smooths the 24 V supply voltage.

Explosion hazard in case of incorrect assembly!

Please observe the following rules under any circumstances!

The Rexroth electronics listed in this data sheet must be installed and operated outside the potentially explosive area. The VT-MUXA2-2 module must be switched between amplifier output and solenoids and between control output (command value presetting by superior control) and amplifier input (see block diagram). Only connect valve solenoids the maximum current of which complies with the monitoring current of the VT-MUXA2-2 monitoring module.

Notice:

The VT-MUXA2-2 module is an electrostatically endangered component. It has to be assembled complying with ESD protective measures.

01

02

03

04

05

06

07

VT-MUXA

2

2

1X

/

V0

1A

*

01

Analog module for monitoring solenoid coils

VT–MUXA

02

Monitoring for valves with one or two solenoids

2

03

Serial number (module type)

2

04

Component series 10 ... 19 (10 ... 19: unchanged technical data and pin assignment)

1X

05

Standard version

V0

06

Imax = 1.0 A

1A

07

Further details in the plain text

*

included in the scope of delivery:

two ferrite sleeves for lines between amplifier and monitoring module conducting solenoid current

General

Component series

1X

Operating voltage

Operating voltage

Nominal value

UB

24 VDC

Maximum value 1)

U(t)max

30 V at 0 °C ≤ ϑU ≤ 40 °C

Minimum value 1)

U(t)min

18 V at 0 °C ≤ ϑU ≤ 40 °C

Reverse polarity protection

yes

Power consumption

P

VA

< 5

Current consumption

I

A

< 0.2

Fuse/short-circuit protection

1 or 2 fuses for the solenoid currents, not exchangeable

I

1.25 A fast-acting (SMD)

Display LEDs (green)

OK

Is illuminated if the self-test has been completed, the relays have operated and there is no error

power

Is illuminated if the internal power supply unit works
1) see also derating characteristic curve on page 7

Inputs

Command value differential input

U

0 … +10 V or 0 … ±10 V, RE = 100 kΩ

Reset input

Low

UR

0 … 6.5 V

High

UR

10 V … UB

1 or 2 monitored solenoid current inputs

Admissible common-mode voltage

U

–2 V … UB

Reverse polarity protection

by means of diodes

Admissible clock frequency of the solenoid currents

0 … 500 Hz

Outputs

Command value output 1)

U

0 … +10 V or 0 … ±10 V, I = 2 mA

2 solenoid current outputs

I

1.0 A (monitored to ±2 %)

OK output

High = OK

UB – 3 V / 50 mA, short-circuit-proof

Low = OK

< 2 V, Ri = 10 kΩ
1) Command value presetting at the amplifier

Other information

Clearances and creepage distances

according to EN 50178

admissible degree of contamination

2 according to EN 60664

Anschlussart

16-pole terminal housing with detachable terminals

Connection cross-section

A

0.2 … 2.5 mm2

Mounting type

Top hat rail TH 35-7.5 according to EN 60715

Protection class

IP 20

Dimensions (W x H x D)

see unit dimensions on page 8

Operating temperature range 1)

ϑ

°C

​0 … +50

Storage temperature range

ϑ

°C

-25 … +85

Weight

m

kg

0.15
1) see also derating characteristic curve on page 7

For applications outside these parameters, please consult us!