Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
VT-HNC100-4-3X/E-I-00/G04
R901293740
Controller Test Rigs

Digital controller HNC 3X

$21,067.00

BOSCH REXROTH

MATERIAL:  R901293740

SUMMARY:  Digital controller HNC 3X

Add to Cart

Scalablein hardware and software (scalable, remote, robust)

The HNC100 is Rexroth's "all-rounder" in hydraulic drive control. Thanks to its distinct interface variety and free programmability, it fulfills various requirements and can be easily and flexibly integrated into any control architecture.

 

Consistent easy application.

Rexroth is the specialist for hydraulic systems – from open loop and closed loop control technology to drive technology. We provide you easily and quickly with our expertise. WinPed7 is the solution. The software tool ensures powerful engineering for an easy and quick implementation of your application.

 

Open to any solution

Regarding control solutions for hydraulic drives, Rexroth also consistently focus on open interfaces and programming standards. The Motion Controls support any commonly used field bus and Ethernet protocol and fit in seamlessly with various automation environments.

 

Best-in-class hydraulic controllers:

Rexroth has gathered unique knowledge of the interaction of hydraulics and Motion Control technology. Based on this knowledge, the control strategies for hydraulic and hybrid drives have been optimized and are represented in immediately usable software.

01

02

03

04

05

06

07

VT-HNC100

3X

/

/

01

VT-HNC100

Serial unit

02

Version Compact for 1 axis

C

Version for 1 hydraulic axis

1

Versions for 2 hydraulic axes

2

Versions for 3 hydraulic axes

3

Versions for 4 hydraulic axes

4

03

Component series 30 ... 39 (30 ... 39: unchanged technical data and pin assignment)

3X

Bus connection

2)

04

PROFIBUS DP

P

CANopen

C

PROFINET RT (not in connection with Compact version)

N

EtherNet/IP (not in connection with Compact version)

E

Position transducer

05

Incremental/SSI (not in connection with Compact version)

I

SSI (only in connection with Compact version)

S

06

no fitting

00

TCP/IP

1)

E0

Option

07

without synchronism

G00

Synchronism 2-axis version

G02

Synchronism 3-axis version

G03

Synchronism 4-axis version

G04

1) Only specify "E0" if the Ethernet service interface is desired for "PROFIBUS DP"
2) Versions without bus connections are not available.

General

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Component series

3X

Voltage supply

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Operating voltage 1)

UB

18 to 30 VDC, residual ripple < 1.5 V

Current consumption at 24 VDC

I

approx. 500 mA 1 to 4 A (depending on the HNC variant and the also supplied components)
1) If a 24 V encoder supply is implemented directly via the VT-HNC100...3X (supply voltage is looped in), the encoder specification has to be observed.

Analog inputs (AI)

Type / version

VT-HNC100-C-3X

Voltage input (reference to AGND - Analog ground)

Channel number

1

Input voltage

UE

max. +12 V to –12 V (+10 V to –10 V measurable)

Input resistance

RE

200 kΩ ± 5 %

Resolution

5 mV

Non-linearity

%

< 0.2

Calibration tolerance, max. 1)

40 mV (with factory settings)

Current inputs

Channel number

2

Input current

IE

4 mA to 20 mA

Input resistance

RE

225 Ω at 20 °C (100 Ω measuring resistance)

Leakage current

IV

0.1 to 0.4 % (with 100 Ω between pin 2 or pin 3 (Cin1+ or Cin2+) and "AGND"

Resolution

5 μA

Voltage supply for analog sensors via VT-HNC100-C-3X

UB at X2A, pin 7 (+24 Vsens)
1) If the factory settings are insufficient, the measurement technology can be calibrated on site via software in a system-specific way.

Analog inputs (AI) per axis electronics

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Voltage inputs (differential inputs)

Channel number

2

Input voltage

UE

max. +12 V to –12 V (+10 V to –10 V measurable)

Input resistance

RE

200 kΩ ± 5 %

Resolution

5 mV

Non-linearity

%

< 0.2

Calibration tolerance, max. 1)

40 mV (with factory settings)

Current inputs

Channel number

2

Input current

IE

4 mA to 20 mA

Input resistance

RE

350 Ω at 20 °C (100 Ω measuring resistance)

Leakage current

IV

0.1 to 0.4 %

Resolution

5 μA

Voltage supply for analog sensors via VT-HNC100…3X

U

UB at X2A1 to X2A4, pin 14 (+24 Vsens)
1) If the factory settings are insufficient, the measurement technology can be calibrated on site via software in a system-specific way.

Digital inputs (DI)

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Switching inputs (DI)

Number

4 11

Logic level

log 0 (low) ≤ 5 V; log 1 (high) ≥ 10 V to UB, Ie = 20 mA at UB = 24 V

Connection

flexible conductor up to 1.5 mm2

Reference potential for all signals

DGND

Analog outputs (AO)

Type / version

VT-HNC100-C-3X

Voltage outputs

Channel number

2

Output voltage, normalized

Unorm

–10 V to +10 V (max. –10.7 V to +10.7 V)

Output current, max.

Imax

± 10 mA

Load, min.

Rmin

1

Resolution

1.25 mV

Non-linearity

in the range –9.5 V to +9.5 V

%

< 0.1

in the range –10 V to –9.5 V and +9.5 V to +10 V

%

< 0.2

Analog outputs (AO) per axis electronics

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Analog outputs (AO: 1) per axis electronics 1)

2

Non-linearity

in the range –9.5 V to +9.5 V

%

< 0.1

in the range –10 V to –9.5 V and +9.5 V to +10 V

%

< 0.2

Voltage output

Output voltage, normalized

Unorm

–10 V to +10 V (max. –10.7 V to +10.7 V)

Output current, max.

Imax

± 10 mA

Load, min.

Rmin

1

Residual ripple

±60 mV (without noise)

Resolution

1.25 mV

Current output

Output current, normalized

Inorm

4 mA to 20 mA

Load, max.

Rmax

Ω

500

Resolution

0.625 μA
1) Configurable as current or voltage output. Axis electronics slot 1 and axis electronics slot 2 feature two voltage outputs Vout1 and Vout2. Axis electronics slot 3 and axis electronics slot 4 feature one voltage output Vout1.

Digital outputs (DO)

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Switching outputs (DO)

Number

2 11

Logic level

log 0 (low) ≤ 2 V; log 1 (high) ≤ UB; Imax = 20 mA, maximum load capacity C = 0.047 μF

Connection

flexible conductor up to 1.5 mm2

Reference potential for all signals

DGND

Digital position transducers (encoders):

Type / version

VT-HNC100-C-3X

SSI transducer 1)

Coding

Gray code

Data width

adjustable up to max. 28 bit

Line receiver/driver

RS485

Voltage supply via VT-HNC100-C-3X

U

UB

Reference potential for all signals

EGND
1) Due to the higher control quality, an SSI transducer with clock synchronization should be used

Digital position transducers (encoders) per axis electronics

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Incremental transducer with TTL output

Input voltage

log 0

0 to 1 V

log 1

2.8 to 5.5 V

Input current

log 0

-0.8 mA (with 0 V)

log 1

0.8 mA (with 5 V)

Frequency, max. related to Ua1

fmax

kHz

250

Voltage supply for incremental transducers via VT-HNC100…3X

U

5.25 V ±1 %, max. 400 mA total current over all axes at X8M1 to X8M4, Pin 12 (+5 Venc)

SSI transducer 1)

Coding

Gray code

Data width

adjustable up to max. 28 bit

Line receiver/driver

RS485

Voltage supply for SSI transducers via VT-HNC100…3X

U

UB at X8M1 to X8M4, pin 14 (+24 Venc)

Reference potential for all signals

EGND
1) Due to the higher control quality, an SSI transducer with clock synchronization should be used

Other information

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Processor

32 bit power PC

Interface for WIN-PED 6, WIN-PED7

RS232

Bus interface

PROFIBUS DP (max. 12 MBaud acc. to IEC 61158), CANopen RS232, optional TCP/IP
PROFIBUS DP (max. 12 MBaud acc. to IEC 61158), CANopen, PROFINET RT, EtherNet/IP

Installation

Top hat rail TH 35-7.5 or TH 35-15 according to EN 60715

Admissible operating temperature range

ϑ

°C

​0 … +50

Storage temperature range

ϑ

°C

-20 … +70

Protection class according to EN 60529:1991

IP 20

Weight

m

g

440 585 690 850 960

m

223 g 1)

CE conformity

See features
1) with Ethernet, in addition

PROFINET RT, EtherNet/IP

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Minimum cycle time

ms

2

Size of the cyclic I/O data, max.

992 byte (max. 496 byte per direction)

Transmission rate

100 Mbits/s, full-duplex

For applications outside these parameters, please consult us!

System overview (example)

technical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3X

System overview, interfaces (example)

technical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3X

1

Differential cylinder

2

integrated position measurement system

3

Proportional servo valve with integrated control electronics

4

VT-HNC100-1-3X/N...

5

Connection cable

6

Pressure transducer

7

Sandwich plate shut-off valve (with connector switching amplifier)

technical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3Xtechnical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3Xtechnical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3Xtechnical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3Xtechnical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3X

Dimensions in mm

technical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3X

1

Installation on top hat rail TH 35-7.5 or TH 35-15 according to EN 60715

Dimensions in mm

technical illustration-VT-HNC100-4-3X/E-I-00/G04-Digital controller HNC 3X

1

Installation on top hat rail TH 35-7.5 or TH 35-15 according to EN 60715