ABSBG-1X/M 2,0N-CE /10E210G 24V/K6M DC
R901301892
Diaphragm Accumulators

ABSBG Accumulator assembly (Standard)

$3,980.00

BOSCH REXROTH

MATERIAL:  R901301892

SUMMARY:  ABSBG Accumulator assembly (Standard)

Add to Cart

Ordering code

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

ABSBG

-

1X

/

M

N

/

G24

V

/

K

6

01

Accumulator station (with diaphragm accumulator according to directive 2014/68/EU)

ABSBG

02

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

Hydraulic accumulator

03

Design

Diaphragm type accumulator according to data sheet 50150

M

Accumulator volume in l

04

0,7 l

0,7

1,4 l

1,4

2,0 l

2,0

2,8 l

2,8

3,5 l

3,5

Diaphragm material

05

e.g. Acrylonitrile-butadiene rubber (NBR)

N

Country acceptance for hydraulic accumulator

06

Short symbol for country acceptance in Europe, Russia and China from the manufacturer's type key

Acceptance according to 2014/68/EU

CE

Acceptance according to SELO (China)

88/CHN

Acceptance according to EAC (Russia)

71/GOST

Operating instructions

BA

Accumulator shut-off block according to data sheet 50131

07

ABZSS 10 pressure relief valve 6E

10

Accumulator shut-off block ‒ Unloading

08

manual and electro-magnetic

E

manual

M

Accumulator shut-off block ‒ Set pressure at the pressure relief valve

09

100 bar

100

140 bar

140

210 bar

210

330 bar

330

Accumulator shut-off block ‒ Voltage type

10

Direct voltage 24 V

G24

Accumulator shut-off block ‒ Seal material

11

FKM

V

Mounting construction kit

12

Mounting using assembly kit K (console K)

K

ABZMM pressure gauge according to data sheet 50205

13

DN63

6

Pressure gauge scale

14

bar/MPa

M

bar/psi

P

Accumulator manufacturer

15

Bosch Rexroth

DC

Parker Olaer

OL

Order example:
ABSBG-1X/M0,7N-CE/10E140G24V/K6MDC

Accumulators

Design

Diaphragm type accumulators

Installation position

Any, preferably with the fluid connection socket at the bottom

Ambient temperature range

°C

-15 … +65

Line connection

Screw-in thread

Hydraulic fluid 1)

Hydraulic oil according to DIN 51524

Hydraulic fluid temperature range

NBR diaphragm

°C

-10 … +80 2)

ECO diaphragm

°C

-35 … +80

Acceptance specifications

CE/BA

Acceptance according to 2014/68/EU or the operating instructions

China

SELO

Russia

GOST
1) Other hydraulic fluids upon request.
2) Others upon request.

hydraulic, diaphragm type accumulator

Nominal capacity

VNenn

l

0.7 1.4 2 2.8 3.5

Effective gas volume

Veff

l

0.75 1.4 1.95 2.7 3.5

Maximum admissible operating pressure

pmax

bar

350

Maximum admissible pressure fluctuation range

Δpdyn

bar

130

pneumatic

Charging gas

Nitrogen, cleanliness class 4.0, N2 = 99.99 vol. %

Gas filling pressure 1)

p0

bar

2
1) Exception: diaphragm type accumulators with SELO acceptance are not prestressed.

Shut-off block

Seal material

FKM seals (NBR seals on request)

Operating temperature range

°C

-15 … +80

Maximum operating pressure

bar

350

Block material

Steel

Pressure relief valve, direct controlled

DBDS…K1X/…VB or DBDS…K1X/…E according to data sheet 25402

Cartridge seat valve

KSDER1PB/HN9V according to data sheet 18136-20

Protection class according to VDE 0470-1 ‒ version "K4"
(DIN EN 60529) DIN 40050-9 1)

IP65

Voltage type 2)

V

24

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c)

Class 20/18/15
1) With mating connector mounted and locked
2) In case of electro-magnetic unloading "E"

Hydraulic fluids

Classification

Suitable sealing materials

Standards

Mineral oil

HL, HLP

NBR, FKM

DIN 51524

Fast bio-degradable hydraulic fluids

Insoluble in water

HETG

NBR, FKM

VDMA 24568

HEES

FKM

Soluble in water

HEPG

FKM

VDMA 24568

Important information on hydraulic fluids!
For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us!
There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)!
The flash point of the hydraulic fluid used must be 40 K higher than the maximum solenoid surface temperature.
Flame-resistant – containing water: Maximum pressure differential per control edge 50 bar. Pressure pre-loading at the tank port > 20 % of the pressure differential; otherwise, increased cavitation. The pressure peaks should not exceed the maximum operating pressures!
Bio-degradable: When using bio-degradable hydraulic fluids that are zinc-solving, zinc may accumulate in the fluid (700 mg zinc per pole tube).

Pressure gauge

Size

bar

63

Pressure gauge

Glycerin

Double scale

bar/MPa

Surface treatment:

All steel components and components without protective coating are coated prior to installation (minimum corrosion protection time of 12 h in salt spray test). Then, the devices, components and the piping are installed. All components, assemblies, controls, pipes, fittings and standard parts keep the supplied surface protection and are not additionally coated. The corrosion protection is determined by the least protected element in the assembly.

For applications outside these parameters, please consult us!

Symbol

Accumulator station with manually operated drain valve

technical illustration-ABSBG-1X/M 2,0N-CE  /10E210G 24V/K6M  DC-ABSBG Accumulator assembly    (Standard)

Symbol

Accumulator station with electro-mechanically operated drain valve

technical illustration-ABSBG-1X/M 2,0N-CE  /10E210G 24V/K6M  DC-ABSBG Accumulator assembly    (Standard)

1

Hydraulic accumulator

2.1

Accumulator shut-off block with:

2.2

System shut-off cock

2.3

Pressure relief valve (type-examination tested)

2.4

manual unloading

2.5

electro-magnetic unloading (only version “E”)

3

Pressure gauge with red indication of the maximum admissible operating pressure

Dimensions: Mounting with bracket K

Accumulator station with diaphragm type accumulator 0,7 … 3,5 l
Dimensions in mm

technical illustration-ABSBG-1X/M 2,0N-CE  /10E210G 24V/K6M  DC-ABSBG Accumulator assembly    (Standard)

1

Hydraulic accumulator

2

Bracket

3

Shut-off block

4

Pressure gauge with red indication of the maximum admissible operating pressure

5

Space required for filling device

6

Name plate of the accumulator station

7

Functional sign (loose)

8

Warning sign (loose)

9

Threaded connection M8 for equipotential bonding

 

Connection designation

M1

Measuring port G1/4

M2

Pressure gauge connection G1/4

P

Pump connection G1/2

T

Tank port G3/8

The gas filling pressure of the accumulators upon delivery is 2 bar.

ABSBG-...

assembly kit

ØD

H

H1

H2

L

L1

L2

B

SW1

SW2

mm

mm

mm

mm

mm

mm

mm

mm

M0,7/10 128.5 402.5 171 132.5 262 50 105 217 SW41 SW41
M1,4/10 156 427.5 196 132.5 262 50 105 217 SW41 SW41
M2,0/10 156 512.5 281 132.5 262 50 105 217 SW50 SW60
M2,8/10 180 501.5 270 132.5 262 50 105 217 SW55 SW60
M3,5/10 180 541.5 310 132.5 262 50 105 217 SW55 SW60

Commissioning, maintenance and operating instructions

General Information

Observe the documentation for the machinery. Also observe the documentation pertaining to the other components, assemblies and partly completed machinery, which form part of the complete machinery. Observe the generally applicable, legal or otherwise binding European and national regulations as well as the relevant legislation for your country pertaining to the prevention of accidents and protection of the environment. Operating instructions according to data sheet of the accumulator Depending on the country of installation, national pressure vessel regulations need to be complied with. In the standard, the country acceptance is effected according to BA, CE as well as for China and Russia Other acceptances on request. Please indicate the country of installation in the order. Keep all documents included in the delivery in a safe place; they will be required by the expert in recurring tests. The machine end-user will have sole responsibility for complying with existing provisions. The accumulator stations in this edition are assemblies in the sense of directive 2014/68/EU, article 2, section 6 (Pressure Equipment Directive).However, they are not intended for exclusive commissioning. They are installed as a component of a larger assembly or system. The accumulator stations described here contain the entire equipment which is required for safety reasons according to DIN EN ISO 4413. The accumulator stations must not be modified; otherwise, the operating license according to directive 2014/68/EU will be lost and the dealer and/or manufacturer warranty will be forfeited. The accumulator stations may only be operated within the admissible limit values. Repairs may only be carried out by the manufacturer or their authorized dealers and agencies. Repairs performed by third parties invalidate the approval and release the manufacturer from all claims resulting from an unauthorized intervention. Assembly and maintenance must be implemented by authorized, instructed persons only.

 

The accumulator stations are provided with signs:1. Name plate specifying the pressure rating, identifies the device2. Functional sign, identifies the components and elementary lever positions3. Warning sign, has to be clearly visible and attached at the device or next to it.Usually, the warning sign is in the languages according to the country acceptance. Other languages on request.

 

For hydraulic systems with one or several hydraulic accumulators whose warning signs are not visible after installation into the machine, an additional warning sign has to be attached visibly to the system, stating:

"CAUTION - system contains hydraulic accumulators."

The circuit diagram has to contain the same notice. With mounting "B" and "K", the warning signs and functional signs are supplied loosely and must be attached to or close to the accumulator station in a clearly visible position. The attachment of the signs must already be considered in the design.

1: Name plate

technical illustration-ABSBG-1X/M 2,0N-CE  /10E210G 24V/K6M  DC-ABSBG Accumulator assembly    (Standard)

3: Warning sign

technical illustration-ABSBG-1X/M 2,0N-CE  /10E210G 24V/K6M  DC-ABSBG Accumulator assembly    (Standard)

2: Functional sign

technical illustration-ABSBG-1X/M 2,0N-CE  /10E210G 24V/K6M  DC-ABSBG Accumulator assembly    (Standard)

Commissioning - Operating instructions according to data sheet of the accumulator!

DANGER

Do not charge hydraulic accumulators with oxygen or air. Explosion hazard!

Prior to the initial commissioning, the hydraulic accumulator must be filled with nitrogen of class 4.0, pure (N2 content 99.99 vol. %).The preset gas pressure necessary for the operation is indicated in the circuit diagrams and operating instructions. Only use suitable filling and testing devices for filling.We recommend using the charging and test devices by Bosch Rexroth according to data sheet 50150.

 

WARNING

Risk of injury caused by improper assembly. Hydraulic accumulators are energy stores. They may supply the energy for uncontrolled movements to actuators. Before beginning any repairs, the system must be depressurized on the oil and gas side and protected against unauthorized re-start. Do not carry out welding and soldering works or any mechanical processing at the accumulator tank!Any kind of work at the product invalidates the declaration of conformity and the operating license!– Explosion hazard due to welding and soldering works!– Danger of bursting during and after mechanical processing. A warning sign is enclosed to the accumulator station. It is to be attached to or close to the accumulator station in a clearly visible position.

 

Maintenance

ATTENTION

In case of damage at the accumulator bladder or diaphragm, the accumulator will lose its function immediately. Loss of the initial gas tension will lead to damage at the accumulator bladder or the accumulator diaphragm if operation of the system is continued nevertheless. Check the initial gas tension in regular intervals.

 

Legal provisions

Hydraulic accumulators are pressure vessels and subject to the application national provisions and/or regulations valid at the place of installation. In Germany, the Ordinance on Industrial Safety and Health (BetrSichV) applies. As a standard, country acceptances are effected according to BA, CE as well as for China and Russia. Other acceptances on request. Special regulations are to be observed in shipbuilding, aircraft construction, mining, etc. Design, production and testing are effected according to the data sheets according to AD 2000. Installation, equipment and operation are controlled by the "Technical rules Pressure vessels" (TRB).

 

Note pursuant to the EC Machinery Directive 2006/42/EC, according to annex II part 1, section A, manufacturer's declaration:

The assemblies were manufactured in accordance with the harmonized standards DIN EN ISO 4413, DIN EN ISO 12100, EN 983 and EN 60204-1. Commissioning is prohibited until it was confirmed that the machine into which the assemblies are to be integrated complies with the regulations laid down in the EC Directives.

Spare parts and accessories

Diaphragm accumulator with CE/BA acceptance according to data sheet 50150 Shut-off block manual/electrical according to data sheet 50131 Pressure gauge according to data sheet 50205 Warning sign according to RNI 17506-001

Consoles contained in the assembly kit are intended for mounting by means of screws and nuts or for welding to suitable frames or design components.