Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
DBGT-2X/700VP2
R901358101
Proportional Pressure Relief Control Valves

Prop.press.valves: DBG* .-1x/

$21,749.00

BOSCH REXROTH

MATERIAL:  R901358101

SUMMARY:  Prop.press.valves: DBG* .-1x/

Add to Cart

General information

Proportional pressure relief valves type DBGT can be controlled remotely and serve for variable setting and limitation of system pressures up to 700 bar. The system pressure is set by means of a DC motor with self-locking speed reduction transmission. This way, the set pressure is maintained in the event of a voltage failure. Pressure relief valves of this series include a main valve (1) and electric motor (2) with gear (3) as pressure adjustment element.

Functional description

The system pressure is set by means of a DC motor (2) with speed reduction transmission (3). The output shaft of the speed reduction transmission turns the cam (4) that adjusts the preload of the spring (6) via the spring plate (5) to cause a pressure change. The pressure applied to channel P acts on the valve poppet (7). If the hydraulic force on the valve poppet exceeds the spring force, the valve regulates the set pressure by lifting the valve poppet from the valve seat (8) to enable the flow of hydraulic fluid from connection P to T. The cam position (4) and the spring preload is reported back by the actual value potentiometer (9). The integrated amplifier type VT-VRM1-1 enables program control. If the power supply is interrupted (cable break, fuse defect, short-circuit, etc.), the pressure set at the valve remains unchanged.

technical illustration-DBGT-2X/700VP2-Prop.press.valves: DBG* .-1x/

01

02

03

04

05

06

07

DBGT

2X

/

700

V

P2

*

01

Pressure relief valve, direct operated with DC motor actuation

DBGT

02

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6

2X

Pressure rating

03

Set pressure up to 700 bar

700

Pilot flow

04

Pilot oil return, internal

no code

Pilot oil return, external

Y

Seal material

05

FKM seals

V

06

Actual value potentiometer

P2

07

Further details in the plain text

For applications outside these parameters, please consult us!

general

Type

DBGT

Size

6

Component series

2X

Weight

kg

7.2

Installation position

any

Ambient temperature range

°C

-20 … +50

hydraulic

Type

DBGT

Maximum operating pressure

Port P

bar

700

Port T

bar

10

Maximum set pressure

Pressure rating 50 bar

bar

700

Minimum set pressure

at a command value of 0

qVnom - abhängig (siehe Kennlinien)

Maximum flow

l/min

12

Hydraulic fluid

see table

Hydraulic fluid temperature range

°C

-20 … +70

Viscosity range

mm²/s

2.8 … 380

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)

Class 20/18/15 according to ISO 4406 (c)

Hysteresis 2)

%

< 6

Repetition accuracy 3)

%

< 1
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
2) Of the maximum set pressure
3) of the maximum set pressure, determined at Q = 3 l/min and a command value of 50%

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP

NBR / FKM

DIN 51524

Bio-degradable   - insoluble in water

HEES

FKM

VDMA 24568

Flame-resistant   - water-free

HFDU

FKM

ISO 12922

Flame-resistant   - containing water

HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620)

NBR

ISO 12922

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.

Flame-resistant - containing water:
Maximum pressure differential per control edge 210bar, otherwise increased cavitation erosion.
Life cycle as compared to operation with mineral oil HLP 30% to 100%
Maximum fluid temperature 60°C

Bio-degradable: When using hydraulic fluids that are simultaneously zinc-solving, zinc may accumulate (700 mg zinc per pole tube).

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP

NBR / FKM

DIN 51524

Bio-degradable   - insoluble in water

HEES

FKM

VDMA 24568

Flame-resistant   - water-free

HFDU

FKM

ISO 12922

Flame-resistant   - containing water

HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620)

NBR

ISO 12922

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.

Flame-resistant - containing water:
Maximum pressure differential per control edge 210bar, otherwise increased cavitation erosion.
Life cycle as compared to operation with mineral oil HLP 30% to 100%
Maximum fluid temperature 60°C

Bio-degradable: When using hydraulic fluids that are simultaneously zinc-solving, zinc may accumulate (700 mg zinc per pole tube).

electrical

Type

DBGT

Voltage type

Direct voltage

Protection class according to DIN EN 60529

IP65 (with mating connector mounted and locked)

Power supply

V DC

24

Nominal power according to VDE 0580

W

24

Adjustment with actual value potentiometer for cam position feedback: Ordering code “P2”

Mechanical adjustment time, pmin to pmax

s

1.1

Potentiometer

Resistance

5

Power

W

1.75

(measured with HLP46, ϑOil = 40 ±5 °C)

DBGT-2X/700

The characteristic curves were measured without counter pressure in port T (pT = 0 bar).

technical illustration-DBGT-2X/700VP2-Prop.press.valves: DBG* .-1x/

Type DBGT-2X/...

technical illustration-DBGT-2X/700VP2-Prop.press.valves: DBG* .-1x/

Connector connection at DBGT valve with actual value potentiometer

technical illustration-DBGT-2X/700VP2-Prop.press.valves: DBG* .-1x/

Dimensions in mm

technical illustration-DBGT-2X/700VP2-Prop.press.valves: DBG* .-1x/

1

Valve housing

2

DC motor

3

“Y” port for “external” pilot oil return

4

Name plate

5

Valve mounting bores

6

Identical seal rings for ports A, B, P, and T

7

Blind counterbores A and B

8

Locking pin

Recommended valve mounting screws (separate order):

4 hexagon socket head cap screws ISO 4762 - M6 x 80 - 10.9-flZn-240h-L

Tightening torque MA = 12.5 Nm ± 10%; material no. R913000512

Notice: For reasons of stability, exclusively these valve mounting screws may be used.