BOSCH REXROTH
R911170452
I/O RF-FLM: PB
BOSCH REXROTH
MATERIAL: R911170452
SUMMARY: I/O RF-FLM: PB
Quantity in stock: 1
Quantity Details:- Hydrotech Stock: 0 can ship April 29, 2024
- Factory Stock: 1 can ship June 17, 2024
The PROFIBUS bus coupler opens a local bus for up to 16 participants. Additional functions: 8 digital inputs, channel-specific diagnostics, dynamic configuration, short-circuit and overload protection, M12 fast connection technology.
General data
Type |
RF-FLM BK PB M12 DI 8 M12 | |
Sensor connection type |
2-, 3- and 4-wire technology | |
Ambient temperature (operation) |
-25 °C ... +60 °C | |
Air pressure (operation) |
800 ... 1060 hPa | |
Protection type |
IP65/67 |
Interface fieldbus
Type |
RF-FLM BK PB M12 DI 8 M12 | |
Fieldbus system |
PROFIBUS DP | |
Connection type |
M12 connector, B-coded |
Interface local bus
Type |
RF-FLM BK PB M12 DI 8 M12 | |
Designation |
Local bus | |
Connection type |
M12 connector, B-coded | |
Number of participants per station |
16 |
Supply of module electronics
Type |
RF-FLM BK PB M12 DI 8 M12 | |
Connection type |
M12 connector | |
Designation |
UL | |
Supply voltage range |
18 ... 30 V DC, IEC 61131-2 (including ripple) | |
Current carrying capacity of supply connections 1) |
A |
≤ 4 |
Voltage supply logic and sensors ULS |
V DC |
24 |
1) | UL: 2 A, US: 2 A |
Digital inputs
Type |
RF-FLM BK PB M12 DI 8 M12 | |
Number of digital inputs |
8 | |
Connection type |
M12 connector | |
Dimensioning of inputs |
Type 1, acc. to IEC 61131-2 | |
Nominal input voltage |
V DC |
24 |
Reverse polarity protection |
Yes |
Norms and Standards
Type |
RF-FLM BK PB M12 DI 8 M12 | |
Certifications |
UL 508 - - - - - - |
Approvals |
The current approvals can be found at www.boschrexroth.com. |
Dimensions
Type |
RF-FLM BK PB M12 DI 8 M12 | |
A |
mm |
70 |
B |
mm |
178 |
C1 |
mm |
9.3 |
C2 |
mm |
40 |