BOSCH REXROTH
R-IBIL24SEG/F-D-PAC
R911170710

I/O Rexroth Inline PWR modules

$148.11

BOSCH REXROTH

MATERIAL:  R911170710

SUMMARY:  I/O Rexroth Inline PWR modules

Quantity in stock: 1

Quantity Details:
  • Hydrotech Stock: 0 can ship May 1, 2024
  • Factory Stock: 1 can ship June 19, 2024
Add to Cart

This module is designed for use within an Inline station. It can be used to build a fuse-protected sub-circuit (segment circuit) within a main circuit. The module cannot be used to supply power, so it does not come with any reverse polarity or overvoltage protection. This module has an LED for diagnostics and uses two input data bits, which are used to indicate the presence of the supply voltage and the status of the fuse.

General data

Type

R-IB IL 24 SEG/F-D-PAC

Weight 1)

g

59

Operating mode

Process data operation with 2 bits

Ambient temperature (operation)

-25 °C ... +55 °C

Ambient temperature (storage/transport)

-25 °C ... +85 °C

Permissible relative humidity (operation)

10 % ... 95 %, EN 61131-2

Permissible relative humidity (storage/transport)

10 % ... 95 %, EN 61131-2

Air pressure (operation)

70 kPa ... 106 kPa (up to 3000 m above sea level)

Air pressure (storage/transport)

70 kPa ... 106 kPa (up to 3000 m above sea level)

Protection type

IP20, IEC 60529

Protection class

III, VDE 0106, IEC 60536
1) Including plug

Connection data

Type

R-IB IL 24 SEG/F-D-PAC

Designation

Inline connection plug

Connection type

Tension spring modules

Conductor cross-section solid/flexible/AWG

0.2 mm² ... 1.5 mm²
0.2 mm² ... 1.5 mm²
24 ... 16

Interface local bus

Type

R-IB IL 24 SEG/F-D-PAC

Connection type

Data ranking

Transmission speed

kBit/s

500

Inline potentials/performance balance

Type

R-IB IL 24 SEG/F-D-PAC

Supply to the main circuit UM

V DC

24

Logic voltage UL

V DC

7.5

Maximum current consumption from UL

mA

25

Maximum power consumption from UL

W

0.19

Nominal current consumption from UM 1)

A

4
1) Rated value

Supply of module electronics and peripherals via bus coupler/power feed module

Type

R-IB IL 24 SEG/F-D-PAC

Connectivity technology

Potential jumpers

24 V peripheral supply (UM, US)

The main voltage UM is fed in the bus coupler or in a feed module. The segment voltage US is provided automatically at this segment module and protected via the internal fuse. There are no connections for the feed of a supply voltage at the segment module. The module points are only intended for measuring purposes.

Permissible total current in the potential jumpers of the main and segment circuits

Type

R-IB IL 24 SEG/F-D-PAC

Permissible total current in the potential jumpers

A

6.3

Nominal module current

A

4

Tolerance

%

+ 10

Derating of the load current in the segment circuit

Type

R-IB IL 24 SEG/F-D-PAC

Derating

No derating

Protective devices

Type

R-IB IL 24 SEG/F-D-PAC

Overload/short-circuit protection in the segment circuit

Safety fuse 5 x 20 mm with 6.3 A time-lag (maximum value of fuse 8 A. For fuses with a value of greater than 2 A, only use slow fuses!)

Reverse polarity protection

Protection components in the feed module or in the bus coupler

Overvoltage protection

Protection components in the feed module or in the bus coupler

Electrical isolation/insulation of the voltage ranges

Type

R-IB IL 24 SEG/F-D-PAC

Common potentials

24 V main voltage UM, 24 V segment voltage US and GND are on the same potential. FE represents a separate potential area.

Separate potentials in the system of bus coupler/feed module and I/O module

Test distance

Test voltage

5 V supply incoming remote bus/7.5 V supply (bus logic)

500 V AC, 50 Hz, 1 min.

5 V supply to further remote bus/7.5 V supply (bus logic)

500 V AC, 50 Hz, 1 min.

7.5 V supply (bus logic)/24 V supply (peripherals)

500 V AC, 50 Hz, 1 min.

24 V supply (peripherals)/function earth

500 V AC, 50 Hz, 1 min.

Error messages to the higher-level control or computer system

Type

R-IB IL 24 SEG/F-D-PAC

Error message

Peripheral message for triggered or missing fuse
Peripheral message for missing supply voltage UM

Approvals

The current approvals can be found at www.boschrexroth.com.

technical illustration-R-IBIL24SEG/F-D-PAC-I/O Rexroth Inline PWR modules

Dimensions

Type

R-IB IL 24 SEG/F-D-PAC

A

mm

12.2

B

mm

120

C

mm

71.5

Note on dimensions

The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715).