BOSCH REXROTH
R-IBIL24SEG/F-D-PAC
R911170710
I/O Rexroth Inline PWR modules
BOSCH REXROTH
MATERIAL: R911170710
SUMMARY: I/O Rexroth Inline PWR modules
Quantity in stock: 1
Quantity Details:- Hydrotech Stock: 0 can ship May 1, 2024
- Factory Stock: 1 can ship June 19, 2024
This module is designed for use within an Inline station. It can be used to build a fuse-protected sub-circuit (segment circuit) within a main circuit. The module cannot be used to supply power, so it does not come with any reverse polarity or overvoltage protection. This module has an LED for diagnostics and uses two input data bits, which are used to indicate the presence of the supply voltage and the status of the fuse.
General data
Type |
R-IB IL 24 SEG/F-D-PAC | |
Weight 1) |
g |
59 |
Operating mode |
Process data operation with 2 bits | |
Ambient temperature (operation) |
-25 °C ... +55 °C | |
Ambient temperature (storage/transport) |
-25 °C ... +85 °C | |
Permissible relative humidity (operation) |
10 % ... 95 %, EN 61131-2 | |
Permissible relative humidity (storage/transport) |
10 % ... 95 %, EN 61131-2 | |
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Protection type |
IP20, IEC 60529 | |
Protection class |
III, VDE 0106, IEC 60536 |
1) | Including plug |
Connection data
Type |
R-IB IL 24 SEG/F-D-PAC | |
Designation |
Inline connection plug | |
Connection type |
Tension spring modules | |
Conductor cross-section solid/flexible/AWG |
0.2 mm² ... 1.5 mm² 0.2 mm² ... 1.5 mm² 24 ... 16 |
Interface local bus
Type |
R-IB IL 24 SEG/F-D-PAC | |
Connection type |
Data ranking | |
Transmission speed |
kBit/s |
500 |
Inline potentials/performance balance
Type |
R-IB IL 24 SEG/F-D-PAC | |
Supply to the main circuit UM |
V DC |
24 |
Logic voltage UL |
V DC |
7.5 |
Maximum current consumption from UL |
mA |
25 |
Maximum power consumption from UL |
W |
0.19 |
Nominal current consumption from UM 1) |
A |
4 |
1) | Rated value |
Supply of module electronics and peripherals via bus coupler/power feed module
Type |
R-IB IL 24 SEG/F-D-PAC | |
Connectivity technology |
Potential jumpers |
24 V peripheral supply (UM, US) |
The main voltage UM is fed in the bus coupler or in a feed module. The segment voltage US is provided automatically at this segment module and protected via the internal fuse. There are no connections for the feed of a supply voltage at the segment module. The module points are only intended for measuring purposes. |
Permissible total current in the potential jumpers of the main and segment circuits
Type |
R-IB IL 24 SEG/F-D-PAC | |
Permissible total current in the potential jumpers |
A |
6.3 |
Nominal module current |
A |
4 |
Tolerance |
% |
+ 10 |
Derating of the load current in the segment circuit
Type |
R-IB IL 24 SEG/F-D-PAC | |
Derating |
No derating |
Protective devices
Type |
R-IB IL 24 SEG/F-D-PAC | |
Overload/short-circuit protection in the segment circuit |
Safety fuse 5 x 20 mm with 6.3 A time-lag (maximum value of fuse 8 A. For fuses with a value of greater than 2 A, only use slow fuses!) | |
Reverse polarity protection |
Protection components in the feed module or in the bus coupler | |
Overvoltage protection |
Protection components in the feed module or in the bus coupler |
Electrical isolation/insulation of the voltage ranges
Type |
R-IB IL 24 SEG/F-D-PAC | |
Common potentials |
||
24 V main voltage UM, 24 V segment voltage US and GND are on the same potential. FE represents a separate potential area. |
||
Separate potentials in the system of bus coupler/feed module and I/O module |
||
Test distance |
Test voltage | |
5 V supply incoming remote bus/7.5 V supply (bus logic) |
500 V AC, 50 Hz, 1 min. | |
5 V supply to further remote bus/7.5 V supply (bus logic) |
500 V AC, 50 Hz, 1 min. | |
7.5 V supply (bus logic)/24 V supply (peripherals) |
500 V AC, 50 Hz, 1 min. | |
24 V supply (peripherals)/function earth |
500 V AC, 50 Hz, 1 min. |
Error messages to the higher-level control or computer system
Type |
R-IB IL 24 SEG/F-D-PAC | |
Error message |
Peripheral message for triggered or missing fuse Peripheral message for missing supply voltage UM |
Approvals |
The current approvals can be found at www.boschrexroth.com. |
Dimensions
Type |
R-IB IL 24 SEG/F-D-PAC | |
A |
mm |
12.2 |
B |
mm |
120 |
C |
mm |
71.5 |
Note on dimensions |
The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715). |