BOSCH REXROTH
S20-DO-32/1
R911172535
I/O IndraControl S20 Digital:Output
BOSCH REXROTH
MATERIAL: R911172535
SUMMARY: I/O IndraControl S20 Digital:Output
Quantity in stock: 0
This module is designed for use within an S20 station. It is used to output digital signals. The outputs are protected against short circuits and overload.
General data
Type |
S20-DO-32/1 | |
Color |
Gray | |
Weight |
g |
191 |
Ambient temperature (operation) |
-25 °C ... +60 °C | |
Ambient temperature (storage/transport) |
-40 °C ... +85 °C | |
Permissible relative humidity (operation) |
5 % ... 95 % acc. to DIN EN 61131-2 | |
Permissible relative humidity (storage/transport) |
5 % ... 95 % acc. to DIN EN 61131-2 | |
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Protection type |
IP20 | |
Protection class |
III, IEC 61140, EN 61140, VDE 0140-1 |
Connection data
Type |
S20-DO-32/1 | |
Designation |
S20 connector | |
Connection type |
Spring-cage connection with direct plug technology | |
Conductor cross-section solid/flexible/AWG |
0.2 mm² ... 1.5 mm² 0.2 mm² ... 1.5 mm² 24 ... 16 |
|
Stripping length |
mm |
8 |
Interface local bus
Type |
S20-DO-32/1 | |
Connection type |
Bus base module | |
Transmission speed |
MBit/s |
100 |
Power supply to logic
Type |
S20-DO-32/1 | |
Logic voltage UBus 1) |
V DC |
5 |
Maximum current consumption from UBus |
mA |
180 |
Maximum power consumption from UBus |
mW |
900 |
1) | Via bus base module |
Power supply to peripherals
Type |
S20-DO-32/1 | |
Feed to digital output modules UO |
V DC |
24 |
Maximum permitted voltage range 1) |
19.2 V DC ... 30 V DC | |
Current consumption from UO 2) |
A |
8 |
Overvoltage/reverse polarity protection supply voltage |
Electronic (35 V, 0.5 s) / parallel diode; with external security 5 A (only for commissioning) | |
Guarantee 3) |
A |
≤ 8 |
1) | Including all tolerances, including ripple |
2) | Secure externally |
3) | Reverse polarity protection up to 5 A |
Digital outputs
Type |
S20-DO-32/1 | |||
Number of digital outputs |
32 | |||
Connection type |
Direct plug-in technology | |||
Connectivity technology |
1-wire technology | |||
Nominal output voltage |
24 V DC | |||
Output current per channel |
mA |
≤ 500 | ||
Output current per device 1) |
A |
≤ 8 | ||
Nominal load |
Ohmic |
48 Ω; for nominal voltage |
W |
≤ 12 |
Lamps |
for nominal voltage |
W |
≤ 12 | |
Inductance |
1.2 H, 48 Ω; for nominal voltage |
VA |
≤ 12 | |
Signal delay upon activation |
µs |
≤ 150 | ||
Signal delay upon deactivation 2) |
µs |
≤ 200 | ||
Switching frequency |
Max. 5500 per second (for ohmic nominal load) Max. 1 per second (for inductive nominal load) Max. 16 per second (for lamp nominal load) |
|||
Load |
kΩ |
≥ 10 | ||
Energy consumption |
See diagram | |||
Limited inductive cut-off voltage |
UDemag = UO - 47 V (UDemag = demagnetization voltage) | |||
Output voltage in deactivated state |
V |
≤ 1 | ||
Output current in deactivated state |
μA |
≤ 300 | ||
Behavior |
For overload |
Shutdown with automatic restart | ||
For inductive overload |
Output can be destroyed | |||
Reverse voltage protection from short pulses |
Limited reverse voltage protection up to 0.5 A for 1 s | |||
Overcurrent cutoff |
A |
> 0.7 | ||
Output current upon overvoltage in deactivated state |
mA |
< 1 | ||
Short-circuit protection, overload protection of the outputs |
Electronic |
1) | Secure externally |
2) | With ohmic nominal load |
Error messages to the higher-level control or computer system
Type |
S20-DO-32/1 | |
Error message |
Short-circuit/overload of digital outputs |
Electrical isolation/insulation of the voltage ranges
Type |
S20-DO-32/1 | |
Test distance |
Test voltage | |
5 V supply (logic)/24 V supply (peripherals) |
500 V AC, 50 Hz, 1 min. | |
5 V supply (logic)/function earth |
500 V AC, 50 Hz, 1 min. | |
24 V supply (peripherals)/function earth |
500 V AC, 50 Hz, 1 min. |
Mechanical tests
Type |
S20-DO-32/1 | |
Vibration resistance 1) |
g |
5 |
Shock 2) |
25 g, 11 ms duration, semi-sinusoidal shock pulse | |
Continuous shock 3) |
g |
10 |
1) | Acc. to IEC 60068-2-6 |
2) | Acc. to IEC 60068-2-27 |
3) | Acc. to EN 60068-2-29 |
Conformity
Type |
S20-DO-32/1 | ||
Conforms with |
|||
Testing of interference immunity acc. to EN 61000-6-2 |
Discharge of static electricity (ESD) |
Criterion B; 6 kV contact discharge; 8 kV air discharge acc. to EN 61000-4-2/IEC 61000-4-2 | |
Electro-magnetic fields |
Criterion A; field strength: 10 V/m acc. to EN 61000-4-3/IEC 61000-4-3 | ||
Fast transients (burst) |
Criterion B; 2 kV acc. to EN 61000-4-4/IEC 61000-4-4 | ||
Transient overvoltage (surge) |
Criterion B; supply lines DC: ±0.5 kV/±0.5 kV (symmetric/asymmetric) acc. to EN 61000-4-5/IEC 61000-4-5 | ||
Line-fed disturbances |
Criterion A; test voltage 10 V acc. to EN 61000-4-6/IEC 61000-4-6 | ||
Testing of disturbance transmission acc. to EN 61000-6-3 |
Radio disturbance characteristics |
Class B acc. to EN 55022 |
Approvals |
The current approvals can be found at www.boschrexroth.com. |
Dimensions
Type |
S20-DO-32/1 | |
A |
mm |
53.6 |
B |
mm |
126.1 |
C |
mm |
54 |
Note on dimensions |