The Sercos gateway module upgrades the SafeLogic compact safety controller by adding a Sercos communication interface for integration into the higher-level automation network. All the modules transfer non-safety-related data for control and diagnostic purposes to the master control systems. In addition, the Sercos gateway allows the safety-related connecting of the IndraDrive range of drives featuring SafeMotion.
General data
Type |
SLC-3-GS3S | |
Weight 1) |
g |
130 |
Ambient temperature (operation) |
-25 °C ... +55 °C | |
Ambient temperature (storage) |
-40 °C ... +70 °C | |
Permissible relative humidity (operation) |
10 ... 95%, no dewing | |
Climatic conditions |
+55 °C ambient temperature, 95 % relative humidity, acc. to EN 61131-2 | |
Electromagnetic compatibility (EMC) |
Class A, acc. to EN 61000-6-2, EN 55011 | |
Protection type terminals |
IP20, EN 60529 | |
Protection type housing |
IP40, EN 60529 |
1) | ±10 % |
Safety technological parameters
Type |
SLC-3-GS3S | |
Safety integrity level acc. to IEC 61508 |
SIL 3 | |
Safety integrity level acc. to EN 62061 |
SILCL3 | |
Category acc. to EN ISO 13849-1 |
Category 4 | |
Performance level acc. to EN ISO 13849-1 |
PL e | |
PFHd acc. to EN ISO 13849 |
0.4*10-9 - |
|
TM (service life) acc. to EN ISO 13849 |
20 a |
Electrical data
Type |
SLC-3-GS3S | |
Protection class |
III, DIN EN 61140 | |
Type of voltage supply |
Via FLEXBUS+ | |
Internal power consumption |
W |
≤ 2.7 |
Interfaces
Type |
SLC-3-GS3S | |
Fieldbus |
Sercos - - - |
|
Connection type system connector |
2 x RJ45 | |
Data transfer rate |
100 Mbits/s (100 Base-Tx) |
Mechanical tests
Type |
SLC-3-GS3S | |
Vibration resistance |
3 g RMS, 10 … 500 Hz, acc. to EN 60068-2-64 - |
|
Shock |
30 g, 11 ms, acc. to EN 60068-2-27 | |
Continuous shock |
10 g, 16 ms, acc. to EN 60068-2-27 |
Safety Technology
SafeMotion
Safety Technology
SafeMotion
Maximum level of safety (Cat. 4, PL e, SIL 3) for all safety functions Safe absolute end position replaces hardware limit switch by software 31 safe cam areas configurable Reduced commissioning effort due to semi-automatic support PC-free device replacement when servicingApplication description
CAD Download
Dimensions
Type |
SLC-3-GS3S | |
A |
mm |
22.5 |
B |
mm |
96.5 |
C |
mm |
120.6 |