Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
S20-SSDI-8/4
R911173191
All Other Products

I/O IndraControl S20 Digital:SIL3 Input

$1,114.35

BOSCH REXROTH

MATERIAL:  R911173191

SUMMARY:  I/O IndraControl S20 Digital:SIL3 Input

Quantity in stock: 1

Quantity Details:
  • Hydrotech Stock: 0 can ship May 1, 2024
  • Factory Stock: 1 can ship June 19, 2024
Add to Cart

Safety-related digital input module, IP20 protection, for use in CIP Safety on Sercos systems. The module has 4 safe digital inputs for two-channel assignment or 8 safe digital inputs for single-channel assignment.

General data

Type

S20-SSDI-8/4

Weight 1)

g

≈ 220

Operating mode

CSos, extended data format with 12 bytes

Ambient temperature (operation) 2)

-35 °C ... +60 °C

Ambient temperature (operation) 3)

-35 °C ... +55 °C

Ambient temperature (storage/transport)

-40 °C ... +85 °C

Permissible relative humidity (operation)

75% on average, 85% occasionally (no condensation)

Permissible relative humidity (storage/transport)

75% (no dewing)

Air pressure (operation)

70 kPa … 108 kPa (up to 3000 m above sea level)

Air pressure (storage/transport)

66 kPa … 108 kPa (up to 3500 m above sea level)

Protection type 4)

IP20

Protection class 5)

III, IEC EN 61140, VDE 0140-1

Clearances and creepage distances

Acc. to IEC 60664-1

Housing material

Plastic PBT, self-extinguishing (V0)

Connection data

Type

S20-SSDI-8/4

Designation

S20 connector

Connection type

Tension spring modules

Conductor cross-section solid/flexible/AWG

0.5 mm² ... 1.5 mm²
0.25 mm² ... 1.5 mm²
24 ... 16

Stripping length

mm

8

Safety characteristics

Type

S20-SSDI-8/4

Acc. to IEC 61508/EN 61508

Achievable SIL 6)

SIL 2 (single-channel)
SIL 3 (two-channel)
-

Probability of dangerous failure by demand through the safety function (PFD)

SIL 2: Maximum 1 % of 10-2 (corresponds to 1 * 10-4)
SIL 3: Maximum 1 % of 10-3 (corresponds to 1 * 10-5)

Probability of dangerous failure per hour for the whole module (PFH) 7)

SIL 2: Maximum 1 % of 10-6 (corresponds to 1 * 10-8)
SIL 3: Maximum 1 % of 10-7 (corresponds to 1 * 10-9)
-

Hardware error tolerance (HFT) of the module

1

Permissible operating time 8)

Years

20

Acc. to EN 62061

Achievable SIL Claim Limit 6)

SIL CL 2 = SIL 2 (single-channel)
SIL CL 3 = SIL 3 (two-channel)
-

Safe Failure Fraction (SFF)

%

99

Probability of dangerous failure per hour for the whole module (PFH) 7)

SIL 2: Maximum 1 % of 10-6 (corresponds to 1 * 10-8)
SIL 3: Maximum 1 % of 10-7 (corresponds to 1 * 10-9)
-

Hardware error tolerance (HFT) of the module

1

Permissible operating time 9)

Years

20

Acc. to EN ISO 13849-1

Achievable Performance Level 6)

PL d (single-channel)
PL e (two-channel)
-

Degree of diagnostic cover (DC)

%

99

Mean time to a dangerous failure (MTTFd) 10)

100 years
-

Supply voltage UBus (Logic)

Type

S20-SSDI-8/4

Logic voltage UBus

V DC

5

Typical current consumption from UBus

mA

260

Maximum current consumption from UBus

mA

310

Supply voltage UI (Sensors, clock outputs, peripherals)

Type

S20-SSDI-8/4

Nominal voltage 11)

V DC

24

Ripple

Vpp

3.6

Permissible voltage range 12)

​19.2 V DC ... ​30.2 V DC

Typical current consumption from UI 13)

mA

9

Permitted interruption time 14)

ms

1

Overvoltage protection

Yes

Reverse polarity protection

Parallel, temporarily reversed polarity protection

Undervoltage detection

V

≈ 16.6

Diagnosis displays

LED (green) UI

External protection 15)

A

≤ 8

Safe digital inputs

Type

Number of digital inputs

Dimensioning of inputs

Supply

Typical input current

Maximum permissible current "0" signal

Minimum permissible current "1" signal

Permissible input voltage range

Input voltage range "0" signal

Input voltage range "1" signal

Maximum switching frequency

Filter time

tFilters

Minimum

Processing time for the input

Simultaneity

Evaluation of the symmetry

Derating

Permissible cable length

Status display

Clock outputs

Type

S20-SSDI-8/4

Number of clock outputs

2

Supply

Off UI

Maximum switching current 16)

A

≤ 0.4

Saturation voltage

UI ‒ 1 V

Simultaneity

%

100

Derating

No

Permissible cable length 17)

m

1000

Status indicators

None

Diagnosis displays

E-LED for imaging the diagnostic condition

Mechanical tests

Type

S20-SSDI-8/4

Vibration resistance 18)

10 ... 57 Hz: 0.35 mm with constant amplitude; 57 ... 150 Hz; 5 g acceleration, constant amplitude

Shock 19)

30 g, 11 ms; criterion A

Conformity

Type

Conforms with

Testing of interference immunity acc. to EN 61000-6-2

Discharge of static electricity (ESD)

Electro-magnetic fields

Fast transients (burst)

Transient overvoltage (surge)

Line-fed disturbances

Testing of disturbance transmission acc. to EN 61000-6-4

Testing of line-fed disturbance transmission

1) Including plug
2) Any installation position
3) Acc. to CULUS
4) Operation min. in installation space IP54
5) Protective extra-low voltage
6) Depending on the parameterization and circuit
7) Depending on the parameterization
8) With low demand rate, 25 years
9) With low demand rate, 25 years. Operation in the faulty state: 72 h
10) Single-channel or two-channel allocation
11) Acc. to EN 61131-2, EN 60204
12) Including all tolerances, including ripple
13) All inputs set; supply from UI with 30.2 V DC; without supply of sensors via clock supplies T1 and T2
14) Output voltage of the clock outputs can break down
15) Slow time-lag
16) Short-circuit and overload proof
17) Total of connected up lines for each clock output must not be exceeded
18) Acc. to IEC 60068-2-6
19) Acc. to IEC 60068-2-27

Approvals

The current approvals can be found at www.boschrexroth.com.

technical illustration-S20-SSDI-8/4-I/O IndraControl S20 Digital:SIL3 Input

Dimensions

Type

S20-SSDI-8/4

A

mm

53.6

B

mm

126.1

C

mm

54

Note on dimensions

Without bus base module including plug