BOSCH REXROTH
S20-DI-16/1-HS
R911173344
All Other Products

I/O IndraControl S20 Digital:Input

$881.29

BOSCH REXROTH

MATERIAL:  R911173344

SUMMARY:  I/O IndraControl S20 Digital:Input

Quantity in stock: 2

Quantity Details:
  • Hydrotech Stock: 0 can ship April 30, 2024
  • Factory Stock: 2 can ship June 18, 2024
Add to Cart

This module is designed for use within an S20 station. It is used to acquire digital signals. The internal update time of < 5 μs makes it possible to applicatively implement a counting function using the module. The input frequency for counting can be a maximum 100 kHz.

General data

Type

S20-DI-16/1 HS

Color

Gray

Weight 1)

g

133

Ambient temperature (operation)

-25 °C ... +60 °C

Ambient temperature (storage/transport)

-40 °C ... +85 °C

Permissible relative humidity (operation)

5 % ... 95 %, no dewing

Permissible relative humidity (storage/transport)

5 % ... 95 %, no dewing

Air pressure (operation)

70 kPa ... 106 kPa (up to 3000 m above sea level)

Air pressure (storage/transport)

70 kPa ... 106 kPa (up to 3000 m above sea level)

Protection type

IP20

Protection class

III, IEC 61140, EN 61140, VDE 0140-1

Installation position

Any (no temperature derating)
1) Including plug and bus base module

Connection data

Type

S20-DI-16/1 HS

Designation

S20 connector

Connection type

Push-in technology

Conductor cross-section solid/flexible/AWG

0.2 mm² ... 1.5 mm²
0.2 mm² ... 1.5 mm²
24 ... 16

Stripping length

mm

8

Interface local bus

Type

S20-DI-16/1 HS

Connection type

Bus base module

Transmission speed

MBit/s

100

Power supply to logic

Type

S20-DI-16/1 HS

Logic voltage UBus 1)

V DC

5

Maximum current consumption from UBus

mA

120

Maximum power consumption from UBus

mW

600
1) Via bus base module

Power supply to peripherals

Type

S20-DI-16/1 HS

Feed to digital input modules UI

V DC

24

Maximum permitted voltage range 1)

​19.2 V DC ... ​30 V DC

Current consumption from UI

mA

20

Typical power consumption from UI

mW

380

Maximum power consumption from UI

mW

480

Overvoltage/reverse polarity protection supply voltage

Electronic (35 V, 0.5 s) / parallel diode; with external security 5 A (only for commissioning)

Guarantee 2)

A

≤ 8
1) Including all tolerances, including ripple
2) Reverse polarity protection up to 5 A

Digital inputs

Type

S20-DI-16/1 HS

Number of digital inputs

16

Connection type

Push-in technology

Connectivity technology

1-wire technology

Description of the input

Acc. to EN 61131-2 type 1 and type 3

Nominal input voltage

V DC

24

Input voltage range

-3 V DC ... 30 V DC

Nominal input current

mA

2.3

Current profile

Linear up to nominal current, then constant around 2.3 mA

Input voltage range "0" signal

-3 V DC ... 8.4 V DC

Input voltage range "1" signal

9.4 V ... 30 V DC

Input filter time

< 5 μs

Process data update 1)

µs

< 5

Reverse polarity protection

Parallel diode (30 V, 5 s)
1) Bus synchronous

PROFIBUS telegram data

Type

S20-DI-16/1 HS

Need for parameter data

byte

3

Need for configuration data

byte

6

Error messages to the higher-level control or computer system

Type

S20-DI-16/1 HS

Error message

Failure in peripheral supply

Electrical isolation/insulation of the voltage ranges

Type

S20-DI-16/1 HS

Test distance

Test voltage

5 V supply (logic)/24 V supply (peripherals)

500 V AC, 50 Hz, 1 min.

5 V supply (logic)/function earth

500 V AC, 50 Hz, 1 min.

24 V supply (peripherals)/function earth

500 V AC, 50 Hz, 1 min.

Mechanical tests

Type

S20-DI-16/1 HS

Vibration resistance 1)

g

5

Shock 2)

g

30

Continuous shock 2)

g

10
1) Acc. to EN 60068-2-6/IEC 60068-2-6
2) Acc. to EN 60068-2-27/IEC 60068-2-27

Conformity

Type

S20-DI-16/1 HS

Conforms with

Testing of interference immunity acc. to EN 61000-6-2

Discharge of static electricity (ESD)

Criterion B; 6 kV contact discharge; 8 kV air discharge acc. to EN 61000-4-2/IEC 61000-4-2

Electro-magnetic fields

Criterion A; field strength: 10 V/m acc. to EN 61000-4-3/IEC 61000-4-3

Fast transients (burst)

Criterion B; 2 kV acc. to EN 61000-4-4/IEC 61000-4-4

Transient overvoltage (surge)

Criterion B; supply lines DC: ±0.5 kV/±0.5 kV (symmetric/asymmetric) acc. to EN 61000-4-5/IEC 61000-4-5

Line-fed disturbances

Criterion A; test voltage 10 V acc. to EN 61000-4-6/IEC 61000-4-6

Testing of disturbance transmission acc. to EN 61000-6-3

Radio disturbance characteristics

Class B acc. to EN 55022

Approvals

The current approvals can be found at www.boschrexroth.com.

technical illustration-S20-DI-16/1-HS-I/O IndraControl S20 Digital:Input

Dimensions

Type

S20-DI-16/1 HS

A

mm

35

B

mm

126.1

C

mm

54

Note on dimensions

The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715).