BOSCH REXROTH
MATERIAL: R911173634
SUMMARY: I/O Rexroth Inline Analogue modules
Quantity in stock: 1
Quantity Details:- Hydrotech Stock: 0 can ship May 8, 2024
- Factory Stock: 1 can ship June 26, 2024
This module is designed for use within an Inline station. It is used to output analog current or voltage signals.
General data
Type |
R-IB IL AO 2/UI-PAC | |
Weight 1) |
g |
66 |
Ambient temperature (operation) |
-25 °C ... +55 °C | |
Ambient temperature (storage/transport) |
-25 °C ... +85 °C | |
Permissible relative humidity (operation) |
10 % ... 95 % acc. to DIN EN 61131-2 | |
Permissible relative humidity (storage/transport) |
10 % ... 95 % acc. to DIN EN 61131-2 | |
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Protection type |
IP20 | |
Protection class |
III, IEC 61140, EN 61140, VDE 0140-1 |
1) | Including plug |
Connection data
Type |
R-IB IL AO 2/UI-PAC | |
Designation |
Inline connection plug | |
Connection type |
Spring-cage connection | |
Conductor cross-section solid/flexible/AWG |
0.08 mm² ... 1.5 mm² 0.08 mm² ... 1.5 mm² 28 ... 16 |
Interface local bus
Type |
R-IB IL AO 2/UI-PAC | |
Connection type |
Inline data jumper | |
Number |
2 | |
Transmission speed |
kBit/s |
500 |
Transfer physics |
Copper |
Inline potentials/performance balance
Type |
R-IB IL AO 2/UI-PAC | ||
Logic voltage UL 1) |
V DC |
7.5 | |
Typical current consumption from UL |
mA |
55 | |
Maximum current consumption from UL |
mA |
65 | |
Peripheral supply voltage UANA |
V DC |
24 | |
Typical current consumption from UANA |
No load |
mA |
24 |
Voltage nominal load UOUT1/2 = 10 V, RL = 1 kΩ |
mA |
38 | |
Power nominal load IOUT1/2 = 20 mA, RL = 0 Ω |
mA |
65 | |
Maximum current consumption from UANA |
No load |
mA |
30 |
Voltage nominal load UOUT1/2 = 10 V, RL = 1 kΩ |
mA |
45 | |
Power nominal load IOUT1/2 = 20 mA, RL = 0 Ω |
mA |
75 | |
Typical power consumption |
Voltage nominal load UOUT1/2 = 10 V, RL = 1 kΩ |
W |
1.32 |
Power nominal load IOUT1/2 = 20 mA, RL = 0 Ω |
W |
1.97 |
1) | Via potential jumpers |
Analog outputs
Type |
R-IB IL AO 2/UI-PAC | |
Number of analog outputs |
2 | |
Connectivity technology |
2-wire technology (shielded, twisted pair) | |
Resolution D/A |
bits |
12 |
D/A conversion time |
µs |
10 |
Output value representation |
12 bits (11 bits + sign) | |
Data formats |
IB IL | |
Process data update |
Bus synchronous | |
Permissible cable length 1) |
m |
≤ 250 |
Short-circuit protection, overload protection |
Electronic | |
Transient protection |
Suppressor diode |
1) | The information relates to nominal operation in compliance with the installation regulations and refer to the following reference line type: Shielded power plant line: LiYCY; 2 x 2 x 0.5 mm2; VDE0812 |
Analog outputs, current
Type |
R-IB IL AO 2/UI-PAC | |
Current output signal |
0 mA ... 20 mA 4 mA ... 20 mA -20 mA ... 20 mA |
|
Output load current output |
Ω |
≤ 450 |
Precision |
Typ. 0.1 % (of the output range end value) |
Analog outputs, voltage
Type |
R-IB IL AO 2/UI-PAC | |
Voltage output signal |
0 V ... 10 V -10 V ... 10 V |
|
Output load voltage output |
kΩ |
> 1 |
Precision |
Typ. 0.1 % (of the output range end value) |
Programming data
Type |
R-IB IL AO 2/UI-PAC | |
ID code (hex) |
5B | |
ID code (dec) |
91 | |
Length code (hex) |
04 | |
Length code (dec) |
04 | |
Process data channel |
bits |
64 |
Input address room |
byte |
8 |
Output address room |
byte |
8 |
Parameter channel (PCP) |
byte |
0 |
Register length (bus) |
bits |
64 |
Fieldbus data telegram
Type |
R-IB IL AO 2/UI-PAC | |
Need for parameter data |
byte |
10 |
Need for configuration data |
byte |
5 |
Error messages to the higher-level control or computer system
Type |
R-IB IL AO 2/UI-PAC | |
Error message |
Upon failure of the internal peripheral power supply: Peripheral error message to the bus coupler Upon failure of the peripheral power supply: Message in the diagnostic code (in format IB IL) Upon short-circuit/overload of outputs: Message in the diagnostic code (in format IB IL) Upon invalid configuration: Message in the diagnostic code (in format IB IL) |
Electrical isolation/insulation of the voltage ranges
Type |
R-IB IL AO 2/UI-PAC | |
Test distance |
Test voltage | |
7.5 V supply (bus logic), 24 V supply UANA/peripherals |
500 V AC, 50 Hz, 1 min. | |
7.5 V supply (bus logic), 24 V supply UANA/function earth |
500 V AC, 50 Hz, 1 min. | |
24 V supply (peripherals)/function earth |
500 V AC, 50 Hz, 1 min. |
Conformity
Type |
R-IB IL AO 2/UI-PAC | ||
Conforms with |
|||
Testing of interference immunity acc. to EN 61000-6-2 |
Discharge of static electricity (ESD) |
Criterion B; 6 kV contact discharge; 8 kV air discharge acc. to EN 61000-4-2/IEC 61000-4-2 | |
Electro-magnetic fields |
Criterion A; field strength: 10 V/m acc. to EN 61000-4-3/IEC 61000-4-3 | ||
Fast transients (burst) |
Criterion B; 2 kV acc. to EN 61000-4-4/IEC 61000-4-4 | ||
Transient overvoltage (surge) |
Criterion B; supply lines DC: ±0.5 kV/±0.5 kV (symmetric/asymmetric); ±1 kV on shielded I/O lines acc. to EN 61000-4-5/IEC 61000-4-5 | ||
Line-fed disturbances |
Criterion A; test voltage 10 V acc. to EN 61000-4-6/IEC 61000-4-6 | ||
Testing of disturbance transmission acc. to EN 61000-6-3 |
Radio disturbance characteristics |
Class A acc. to EN 55022 |
Approvals |
The current approvals can be found at www.boschrexroth.com. |
Dimensions
Type |
R-IB IL AO 2/UI-PAC | |
A |
mm |
12.2 |
B |
mm |
136.8 |
C |
mm |
71.5 |
Note on dimensions |
The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715). |