This module is designed for use within an S20 station. It has four relay N/O contacts that are independent from each other and floating. Low voltage and extra low voltage modules can be used directly next to each other in an S20 station.
General data
Type |
S20-DOR-4/2-220-AC | |
Color |
Gray | |
Weight 1) |
g |
206 |
Ambient temperature (operation) |
-25 °C ... +60 °C | |
-25 °C ... +50 °C | ||
-25 °C ... +40 °C | ||
Ambient temperature (storage/transport) |
-40 °C ... +85 °C | |
Permissible relative humidity (operation) |
5 % ... 95 %, no dewing | |
Permissible relative humidity (storage/transport) |
5 % ... 95 %, no dewing | |
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Protection type |
IP20 | |
Installation position |
Any (pay attention to temperature and power derating) | |
Degree of contamination |
2 | |
Overvoltage class |
III (EN 61010-2-201/UL 61010-2-201), up to 2000 m above sea level; II (EN 61010-2-201/UL 61010-2-201), up to 3000 m above sea level |
1) | Including plug and bus base module |
2) | Max 6 A/channel for wall mounting on a horizontal support rail; max. 4 A/channel for any installation position |
3) | Max 8 A/channel for wall mounting on a horizontal support rail; max. 6 A/channel for any installation position |
4) | Max. 8 A/channel in any installation position |
Connection data
Type |
S20-DOR-4/2-220-AC | |
Designation |
S20 connector | |
Connection type |
Push-in technology | |
Conductor cross-section solid/flexible/AWG |
0.2 mm² ... 1.5 mm² 0.2 mm² ... 1.5 mm² 24 ... 16 |
|
Stripping length |
mm |
8 |
Interface local bus
Type |
S20-DOR-4/2-220-AC | |
Connection type |
Bus base module | |
Transmission speed |
MBit/s |
100 |
Power supply to logic
Type |
S20-DOR-4/2-220-AC | |
Logic voltage UBus 1) |
V DC |
5 |
Maximum current consumption from UBus 2) |
mA |
280 |
Maximum power consumption from UBus 2) |
W |
1.4 |
1) | Via bus base module |
2) | All relays tightened |
Relay output
Type |
S20-DOR-4/2-220-AC | ||
Number of outputs 1) |
4 | ||
Connection type |
Push-in technology | ||
Connectivity technology |
2-wire | ||
Nominal output voltage |
220 V DC, 230 V AC | ||
Output voltage range |
24 V DC ... 220 V DC -20 %/+15 % 24 V AC ... 230 V AC -20 %/+15 % (50/60 Hz) |
||
Output current |
Per channel |
A |
≤ 8 |
Per module |
A |
32 | |
Switch-on current |
Max. 15 A (for 4 s), max. 65 A (for 0.02 s) | ||
Contact version |
4 floating N/O contacts | ||
Contact material |
AgSnO2 | ||
Switching current 2) |
A |
≤ 8 | |
Switching capacity 3) |
VA |
≤ 2000 | |
Switching capacity acc. to IEC 60947-5-1 |
6 A (120 V (AC-15)) | ||
3 A (240 V (AC-15)) | |||
0.22 A (125 V (DC-13)) | |||
0.1 A (250 V (DC-13)) | |||
Switching frequency |
No load |
Hz |
20 |
With load |
Hz |
0.1 | |
Nominal current consumption 4) |
mW |
212 | |
Typical response delay |
ms |
10 | |
Typical bouncing time |
ms |
3 | |
Typical release time |
ms |
5 | |
Service life |
Mechanical |
10*106 switching cycles | |
Electrical |
100,000 switching cycles | ||
Common potentials |
All contacts floating |
1) | N/O contacts |
2) |
cos phi = 1 DC see load limit curve, e.g. following values: max. 8 A DC (≤30 V, ohmic load) max. 500 mA DC (110 V, ohmic load) max. 250 mA DC (220 V DC, ohmic load) max. 220 mA DC (125 V DC, L/R ≤50 ms, applications with UL approval) max. 110 A DC (250 V DC, L/R ≤50 ms, applications with UL approval) |
3) |
DC see load limit curve, e.g. following values: max. 240 W (30 V DC) max. 55 W (≥60 V DC) max. 25 W (125 V DC, 250 V DC, applications with UL approval) |
4) | Per relay |
PROFIBUS telegram data
Type |
S20-DOR-4/2-220-AC | |
Need for parameter data |
byte |
1 |
Need for configuration data |
byte |
6 |
Error messages to the higher-level control or computer system
Type |
S20-DOR-4/2-220-AC | |
Error message |
None |
Electrical isolation/insulation of the voltage ranges
Type |
S20-DOR-4/2-220-AC | |
Test distance |
Test voltage | |
Relay contact/logic |
4 kV measurement surge voltage (safe separation according to EN 61010-2-201/IEC 61010-2-201) | |
Relay contact/logic |
5 kV pulse test voltage according to EN 61850/IEC 61850 | |
Contact/function earth |
4 kV measurement surge voltage (safe separation according to EN 61010-2-201/IEC 61010-2-201) | |
Contact/function earth |
5 kV pulse test voltage according to EN 61850/IEC 61850 | |
Contact/contact (open contact) |
1 kV, 50 Hz, 1 min. | |
Contact/contact (adjacent plugs) |
2.5 kV pulse test voltage according to EN 61850/IEC 61850 |
Mechanical tests
Type |
S20-DOR-4/2-220-AC | |
Vibration resistance 1) |
g |
5 |
Shock 2) |
20 g (contact interruption) / 5 g (contact) | |
Continuous shock 2) |
g |
10 |
1) | Acc. to EN 60068-2-6/IEC 60068-2-6 |
2) | Acc. to EN 60068-2-27/IEC 60068-2-27 |
Conformity
Type |
S20-DOR-4/2-220-AC | ||
Conforms with |
|||
Testing of interference immunity acc. to EN 61000-6-2 |
Discharge of static electricity (ESD) |
Criterion A; 6 kV contact discharge; 8 kV air discharge acc. to EN 61000-4-2/IEC 61000-4-2 | |
Electro-magnetic fields |
Criterion A; 20 V/m to 1 GHz, 10 V/m to 3 GHz acc. to EN 61000-4-3/IEC 61000-4-3 | ||
Fast transients (burst) |
Criterion A; 4 kV acc. to EN 61000-4-4/IEC 61000-4-4 | ||
Transient overvoltage (surge) |
Criterion A; ±4 kV (asymmetric) acc. to EN 61000-4-5/IEC 61000-4-5 | ||
Line-fed disturbances |
Criterion A; test voltage 10 V acc. to EN 61000-4-6/IEC 61000-4-6 | ||
Testing of disturbance transmission acc. to EN 61000-6-3 |
Radio disturbance characteristics |
Class B acc. to EN 55022 | |
Developed by norm IEC 61850-3 |
Discharge of static electricity (ESD) |
Criterion A; 6 kV contact discharge; 8 kV air discharge acc. to EN 61000-4-2/IEC 61000-4-2 | |
Electro-magnetic fields |
Criterion A; 20 V/m to 1 GHz, 10 V/m to 3 GHz acc. to EN 61000-4-3/IEC 61000-4-3 | ||
Fast transients (burst) |
Criterion A; 4 kV acc. to EN 61000-4-4/IEC 61000-4-4 | ||
Transient overvoltage (surge) |
Criterion A; ±4 kV (asymmetric) acc. to EN 61000-4-5/IEC 61000-4-5 | ||
Line-fed disturbances |
Criterion A; test voltage 10 V acc. to EN 61000-4-6/IEC 61000-4-6 | ||
Interference immunity from magnetic fields |
300 A/m permanent, 1000 A/m for 1 s acc. to EN 61000-4-8/IEC 61000-4-8 | ||
Interference immunity from damped oscillating magnetic fields |
100 A/m acc. to EN 61000-4-10/IEC 61000-4-10 | ||
Interference immunity from conducted, common mode interferences |
30 V permanent, 300 V for 1 s acc. to EN 61000-4-16/IEC 61000-4-16 | ||
Damped oscillating shafts |
2.5 kV (asymmetric) acc. to EN 61000-4-18/IEC 61000-4-18 | ||
Radio disturbance characteristics |
Class B acc. to EN 55022 |
Approvals |
The current approvals can be found at www.boschrexroth.com. |
Dimensions
Type |
S20-DOR-4/2-220-AC | |
A |
mm |
53.6 |
B |
mm |
126.1 |
C |
mm |
54 |
Note on dimensions |
The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715). |