Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
VT-SR7-1X/0/A4VS.250HSSO43A-1608
R978917126
Valve Amplifiers

Anal.contr., Q att valve ampl,card so

$4,823.00

BOSCH REXROTH

MATERIAL:  R978917126

SUMMARY:  Anal.contr., Q att valve ampl,card so

Add to Cart

The amplifier operates with a push-pull output stage with bipolar transistors. The output of this output stage can be connected or disconnected by means of an enable circuit (relay K2). The enable is indicated by the LED "H2" on the front plate being illuminated. The switching voltage of all relays is defined by means of jumpers J12 and J13 to either 0 V or +UB (factory +UB).

The output stage consists of an I controller with connected dither signal generator. The amplitude of the dither signal is set by means of R7. The actuation of the pre-stage (current command value) is made via a PD controller. The actual current value returned is simultaneously indicated by the instrument on the front plate.

The oscillator/demodulator serves for position sensing. It is designed as pluggable printed circuit board the parameters of which are adapted to the respective size of the axial piston unit.

The PD controller is supplied the position command value and the position command value and the actual position value with the D share of the controller only affecting the actual value (velocity feedback).

The zero point can be set via R3 ("NP") from the front plate.

The required symmetric operating voltage +UB is protected against reversed polarity. If the board is not equipped with any voltage regulators for supply of the controller and position transducer electronics, an additional stabilized auxiliary voltage ±UM  is required. The auxiliary voltage port is protected against reversed polarity up to a maximum current of 1 A.

As an option, the amplifier can be equipped with a PID controller (D share only affects the actual value). This controller can be used to superimpose a further control loop (e.g. for drive control). The P and D share can be set at the front plate. The PID controller fitting is customer-specific and therefore has to be specified in the order in plain text. These amplifiers receive a special type designation upon delivery.

01

Valve amplifier for flow control with servo valves

VT-SR7

02

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

03

Without ±15 V voltage regulator

0

With ±15 V voltage regulator

1

04

For axial piston unit

NG40

A4VS40HS

Size 71

A4VS71HS

NG125

A4VS125HS

NG180

A4VS180HS

NG250

A4VS250HS

Size 35

A4VS355HS

NG500

A4VS500HS

NG750

A4VS750HS

NG1000

A4VS1000HS

05

Further details in the plain text

*

01

02

03

04

05

VT-SR7

1X

/

/

*

General

Component series

1X

Type of electronics

Analog

Design

Euro-card

Voltage supply

Operating voltage

with integrated voltage regulator

V

± 24

Upper limit value

V

± 28

Lower limit value

V

± 22

without integrated voltage regulator

V

±24; ±15.0

Upper limit value

V

±28; ±15.2

Lower limit value

V

±22, ±14.8

Current consumption

max.

Imax

A

0.15

Analog inputs

Command value

Voltage 1)

grounded on one side, first input

Ucommand

V

​0 … ±10

Voltage 2)

grounded on one side, second input

Ucommand

V

​0 … ±10

position value 1)

Voltage

U

V

​0 … ±10
1) RE = 50 kΩ
2) RE = 50 kΩ, J9 gesteckt

Digital inputs

Enable 1)

On (active)

U

V

+24 (with J13); 0 (with J12)
1) RE = 700 Ω (relay)

Analog outputs

Valve flow command value

UO

-10 V ≙ +60 mA (J10 plugged)

Solenoid outputs

Solenoid current

max.

Imax

mA

60

Dither signal

340 ±5 % (Ipp = 3 mA)

Other information

Relay

Pickup voltage

U

+24 (UB)

Nominal voltage

U

V

26

Response voltage

U

V

13

Step-back voltage

U

V

1.3 ... 6.5

Switching time

t

ms

4

Coil resistance at 25 °C

R

Ω

700

Reference voltage

Potentiometer supply

U

V

±15 ±2 %  (Imax = 150 mA)

Anschlussart

32-pole male multipoint connector, DIN 41612, design D

Ambient temperature range

ϑ

°C

​0 … ​50

Storage temperature range

ϑ

°C

-20 … ​70

Weight

m

kg

0.3

For applications outside these parameters, please consult us!

technical illustration-VT-SR7-1X/0/A4VS.250HSSO43A-1608-Anal.contr., Q att valve ampl,card so
technical illustration-VT-SR7-1X/0/A4VS.250HSSO43A-1608-Anal.contr., Q att valve ampl,card so technical illustration-VT-SR7-1X/0/A4VS.250HSSO43A-1608-Anal.contr., Q att valve ampl,card so

The amplifier card may only be unplugged and plugged when de-energized.

Command values may only be switched via relays with gold-plated contacts (low voltage, low currents).

Card relays may only be switched (enable, controller change-over, reserve) using contacts with a load capacity of approx. 40 V; 50 mA.

Always shield command and actual value cables; connect shielding to ground (⊥) on the card-side, open at one side.

Do not lay signal lines close to power lines.

Recommendation:

Also shield the solenoid conductors (to ⊥ on one side).

Up to a length of 50 m, use cable type LiYCY 1.5 mm2, for longer lengths please ask.

Notice:
In case of pilot pressure at the adjustment device and if relay K2 is deactivated or the voltage supply is switched off, the pump can swivel to maximum setting.