Hydrotech ecommerce supports the continental US only
SUN HYDRAULICS CORP
CXCBLFV/LH
Load Holding
Cartridge
$98.20
SUN HYDRAULICS CORP
MATERIAL: CXCBLFV/LH
SUMMARY: Cartridge
Quantity in stock: 2
Quantity Details:- Hydrotech Stock: 0 can ship May 13, 2024
- Factory Stock: 2 can ship August 12, 2024
Free-flow, side-to-nose check valves are on/off circuit components that allow free flow from the inlet (port 2) to the outlet (port 1) and block flow in the opposite direction.
- The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
- Two-port check valves share the same cavity for a given frame size, however, pay close attention as flow paths may be in opposite directions.
- These check valves are considered circuit savers for existing circuits where manifold drillings are incorrect. The capacity of side-to-nose (port 2 to port 1) 2-port check valves is approximately 30% less than preferred models with a nose-to-side (port 1 to port 2) flow path.
- Check valves offer extremely low leakage rates with a maximum leakage of less than 1 drop per minute (0,07 cc/min).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Cavity | T-13A |
Series | 1 |
Capacity | 15 gpm60 L/min. |
Maximum Operating Pressure | 3000 psi210 bar |
Maximum Valve Leakage at 110 SUS (24 cSt) | 1 drops/min.0,07 cc/min. |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
Model Weight | .20 lb0,10 kg |
Seal kit - Cartridge | Viton: 990-010-006 |