FTHHXCN
Directional

Cartridge

SUN HYDRAULICS CORP

MATERIAL:  FTHHXCN

SUMMARY:  Cartridge

Due to extremely high demand, please call 888-651-5712 for availability

This valve is a 3-way, 3 position, proportional directional valve. Port 3 is closed in the center position and port 2 and port 4 are drained to port 1. Pilot pressure at port 1 creates a metering orifice between ports 3 and 4 that is proportional to the pressure at 1. Piloting 6 opens 3 to 2. The force balance of the flow forces, spring and pilot pressure results in a degree of partial self compensation as the load pressure changes.

Port 5 is not used.

  • Maximum pilot pressure for ports 1 and 6 should not exceed 500 psi (35 bar).
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • Pressure at ports 1 and 6 directly oppose each other.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-54A
Series 4
Capacity 80 gpm320 L/min.
Minimum Pilot Pressure Required to Shift Valve 80 psi5,5 bar
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@1000 psi80 cc/min.@70 bar
Pilot Volume Displacement .26 in³4,3 cc
Hysteresis ± 2 %± 2 %
Valve Hex Size 1 5/8 in.41,3 mm
Valve Installation Torque 350 - 375 lbf ft475 - 508 Nm
Seal kit - Cartridge Viton: 990-054-006