The 350LE(N) inline filter is suitable for installation into pressure lines.
It basically consists of filter head (1), a screwable filter bowl (2), filter element (3) as well as mechanical/visual maintenance indicator (4). In case of filters with low-pressure-differential-stable filter elements (= code letter pressure differential A), there is an assembled bypass valve (5) by default.
Via the inlet, the fluid reaches the filter element where it is cleaned. The dirt particles filtered out settle in the filter element. Via the outlet, the filtered fluid enters the hydraulic circuit. The filter housing and all connection elements are designed so that pressure peaks – as they may e.g. occur in case of abrupt opening of large control valves due to the accelerated fluid quantity - can be securely absorbed. As of size 0160, the standard equipment comprises a drain screw (6). With size 1000, the filter bowl has a two-part set-up. In this connection, the filter pipe is secured in the filter head against rotation.
For integration of the maintenance indicator into an electric circuit, the mechanical/visual maintenance indicator may be amended by an electronic switching element (7). To this end, the electronic switching element must be attached to the mechanical/visual maintenance indicator and held by means of a locking ring. The electronic switching elements are connected via a mating connector or a cable connection.
The electronic switching element must be ordered separately.
Inline filters are used in hydraulic systems for separating solid materials from fluids and lubricating oils.
Notice:
If the maintenance indicator for the element exchange is not observed, the bypass valve will open if the pressure differential increases. In this way, one part of the flow reaches the clean side of the filter without being filtered. Thus, effective filtration is no longer guaranteed.
350LE(N)
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
|||||
350LE |
– |
– |
– |
– |
‒ |
Frame size |
||||||||
01 |
Inline filter 350 bar |
350LE |
||||||
Filter element |
||||||||
02 |
with filter element according to DIN 24550 |
N |
||||||
Size |
||||||||
03 |
LEN... |
0040 |
||||||
0063 |
||||||||
0100 |
||||||||
0160 |
||||||||
0250 |
||||||||
0400 |
||||||||
0630 |
||||||||
1000 |
||||||||
LE... |
0130 |
|||||||
0150 |
||||||||
Filter rating in μm |
||||||||
04 |
Nominal |
Stainless steel wire mesh, cleanable |
G10 |
|||||
G25 |
||||||||
G40 |
||||||||
G60 |
||||||||
G100 |
||||||||
Absolute |
Non-woven glass fiber media, not cleanable |
H3XL |
||||||
H6XL |
||||||||
H20XL |
||||||||
Glass fiber material generation 5, non-reusable, not cleanable |
PWR10 |
|||||||
Pressure differential |
||||||||
05 |
max. admissible pressure differential of the filter element 30 bar, with bypass valve 7 bar |
A00 |
||||||
max. admissible pressure differential of the filter element 330 bar, without bypass valve |
B00 |
|||||||
Element design |
||||||||
06 |
Standard adhesive in connection with material steel, tin-plated |
00 |
||||||
Special adhesive in connection with element material stainless steel |
HV 1) |
|||||||
Maintenance indicator |
||||||||
07 |
Maintenance indicator, mech./visual, switching pressure 2.2 bar - bypass cracking pressure 3.5 bar |
V2,2 |
||||||
Maintenance indicator, mech./visual, switching pressure 5.0 bar - bypass cracking pressure 7 bar |
V5,0 |
|||||||
Maintenance indicator, mech./visual, switching pressure 8 bar - without bypass valve |
V8,0 |
|||||||
Seal |
||||||||
08 |
NBR |
M |
||||||
FKM |
V |
|||||||
EPDM |
E 2) |
|||||||
Connection |
||||||||
09 |
Frame size |
0040 |
0063-0100 |
0130-0150 |
0160-400 |
0630-1000 |
||
Connection |
||||||||
G1/2 |
● |
X |
Pipe thread according to ISO 228 |
R2 |
||||
G3/4 |
X |
X |
R3 |
|||||
G1 |
X |
● |
X |
R4 |
||||
G1 1/4 |
● |
X |
R5 |
|||||
G1 1/2 |
X |
● |
R6 |
|||||
G 2 |
● |
R8 |
||||||
SAE 1 1/2″ |
X |
SAE flange |
S6 |
|||||
SAE 2″ |
X |
S8 |
||||||
SAE 10 |
X |
Pipe thread according to SAE J1926 |
U3 |
|||||
SAE 12 |
X |
U4 |
||||||
SAE 20 |
X |
U5 |
||||||
SAE 24 |
X |
U6 |
||||||
● = |
Standard port |
|||||||
X = |
Alternative connection possibility |
|||||||
Supplementary information |
||||||||
10 |
Manufacturer's inspection certificate M according to DIN 55350 T18 |
Z1 |
||||||
1) |
Only in connection with FKM and EPDM seal |
|||||||
2) |
Only in connection with maintenance indicator V5.0 |
|||||||
Further versions (filter materials, connections,...) are available upon request. |
general
Size |
0040 | 0063 | 0100 | 0130 | 0150 | 0160 | 0250 | 0400 | 0630 | 1000 | |||
Installation position |
vertical | ||||||||||||
Ambient temperature range |
ϑ |
°C |
-30 … +100 | -10 … +65 | |||||||||
Weight |
m |
kg |
5.7 | 6.3 | 7 | 10.5 | 11.2 | 22.7 | 27.5 | 35.2 | 66.4 | 140.3 | |
Volume |
l |
0.25 | 0.35 | 0.52 | 0.9 | 1.1 | 1.3 | 1.9 | 3 | 4.5 | 6.5 | ||
Material |
Filter head |
GGG | |||||||||||
Filter bowl |
Steel | ||||||||||||
Bypass valve |
Aluminum / steel / POM | ||||||||||||
Seals |
NBR / FKM |
Hydraulic fluid |
Classification |
Suitable sealing materials |
Suitable adhesive |
Standards |
|
Mineral oil |
HLP |
NBR |
Standard |
DIN 51424 |
|
Bio-degradable |
Insoluble in water |
HETG |
NBR |
VDMA 24568 |
|
HEES |
FKM |
||||
Soluble in water |
HEPG |
FKM |
VDMA 24568 |
||
Flame-resistant |
Water-free |
HFDU, HFDR |
FKM |
VDMA 24317 |
|
Containing water |
HFAS |
NBR |
DIN 24320 |
||
HFAE |
NBR |
||||
HFC |
NBR |
VDMA 24317 |
|||
Skydrol |
‒ |
EPDM |
Special “H” |
‒ |
Important information on hydraulic fluids!
For more information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! Flame-resistant – containing water: Due to possible chemical reactions with materials or surface coatings of machine and system components, the service life with these hydraulic fluids may be less than expected. Filter materials made of filter paper P must not be used, filter elements with glass fiber material have to be used instead. Bio-degradable: If filter materials made of filter paper are used, the filter life may be shorter than expected due to material incompatibility and swelling.hydraulic
Size |
0040 | 0063 | 0100 | 0130 | 0150 | 0160 | 0250 | 0400 | 0630 | 1000 | ||
Operating pressure |
pmax |
bar |
350 | |||||||||
Hydraulic fluid temperature range |
ϑ |
°C |
-10 … +100 | |||||||||
Minimum conductivity of the medium |
pS/m |
300 | ||||||||||
Fatigue strength according to ISO 10771 |
Load cycles |
> 10⁶ with operating pressure | ||||||||||
Filtration direction |
From the outside to the inside |
For applications outside these parameters, please consult us!
Filter element (measured with mineral oil HLP46 according to DIN 51524)
Spec. weight: < 0.9 kg/dm3
Δp-Q characteristic curves for complete filter, recommended initial Δp for design = 1.5 bar
Selection of the perfect filter is made possible by our online “Bosch Rexroth FilterSelect“ design software.
350LEN0040-H3XL
350LEN0063-H3XL
350LEN0100-H3XL
350LE0130-H3XL
350LE0150-H3XL
350LEN0160-H3XL
350LEN0250-H3XL
350LEN0400-H3XL
350LEN0630-H3XL
350LEN1000-H3XL
350LEN0040-H10XL
350LEN0063-H10XL
50LEN0100-H10XL
350LE0130-H10XL
350LE0150-H10XL
350LEN0160-H10XL
350LEN0250-H10XL
350LEN0400-H10XL
350LEN0630-H10XL
350LEN1000-H10XL
350LE(N)
350LE(N)
NG |
A1 |
A2 |
A3 1) |
A4 |
A5 |
ØB3 |
ØB4 |
B11 2) |
C1 - Standard |
ØC2 - Standard |
C1 - SAE |
ØC2 - SAE |
C2 |
C4 |
D1 |
D2 |
D3 |
D4 |
D5 |
D6 |
ØW1 |
ØW2 |
W3 |
W5 |
W6 |
SW |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|||||
0040 | 203 | 115 | 80 | 158 | 25 | 64 | 85 | 92 |
G 1/2 G 3/4 G 1 |
28 |
SAE 10 7/8-12 UNF-2B |
34 | M6 | 8 | 32.5 | 30 | 25 | 32 | 47 | 52 | 20 | 32 | ||||
0063 | 266 | 115 | 80 | 221 | 25 | 64 | 85 | 92 |
G1 G 1/2 G 3/4 |
41 |
SAE 12 1 1/16-12 UN-2B |
34 | M6 | 8 | 32.5 | 30 | 25 | 32 | 47 | 52 | 20 | 32 | ||||
0100 | 356 | 115 | 80 | 311 | 25 | 64 | 85 | 92 |
G1 G 1/2 G 3/4 |
41 |
SAE 12 1 1/16-12 UN-2B |
34 | M6 | 8 | 32.5 | 30 | 25 | 32 | 47 | 52 | 20 | 32 | ||||
0130 | 328 | 150 | 140 | 273 | 40 | 92 | 118 | 132 |
G1 1/4 G 1 G 1 1/2 |
51 |
SAE 20 1 5/8-12 UN-2B |
58 | M6 | 8 | 40 | 30 | 40 | 32 | 47 | 52 | 15 | 32 | ||||
0150 | 364 | 150 | 140 | 324 | 40 | 92 | 118 | 132 |
G1 1/4 G 1 G 1 1/2 |
51 |
SAE 20 1 5/8-12 UN-2B |
58 | M6 | 8 | 40 | 30 | 40 | 32 | 47 | 52 | 15 | 32 | ||||
0160 | 322 | 170 | 140 | 262 | 50 | 114 | 140 | 164 |
G1 1/2 G1 1/4 |
56 |
SAE 24 1 7/8-12 UN-2B SAE 1 1/2″, 6000 psi |
65 | M16 | 22 | M8 | 12 | 35 | 30 | 50 | 32 | 32 | 52 | 10 | 32 | ||
0250 | 412 | 170 | 140 | 352 | 50 | 114 | 140 | 164 |
G1 1/2 G1 1/4 |
56 |
SAE 24 1 7/8-12 UN-2B SAE 1 1/2″, 6000 psi |
65 | M16 | 22 | M8 | 12 | 35 | 30 | 50 | 32 | 32 | 52 | 10 | 32 | ||
0400 | 562 | 170 | 140 | 502 | 50 | 114 | 140 | 164 |
G1 1/2 G1 1/4 |
56 |
SAE 24 1 7/8-12 UN-2B SAE 1 1/2″, 6000 psi |
65 | M16 | 22 | M8 | 12 | 35 | 30 | 50 | 32 | 32 | 52 | 10 | 32 | ||
0630 | 605 | 210 | 160 | 540 | 60 | 140 | 185 | 204 | G 2 | 72 | SAE 2", 6000 psi | M20 | 30 | M12 | 12 | 15 | 50 | 40 | 60 | 32 | 32 | 10 | 52 | 5 | 41 | |
1000 | 843 | 210 | 650 | 778 | 60 | 190 | 185 | 204 | G 2 | 72 | SAE 2", 6000 psi | M20 | 30 | M12 | 12 | 15 | 50 | 40 | 60 | 32 | 32 | 10 | 52 | 5 | 41 |
1) | Servicing height for filter element exchange |
2) | if there is no maintenance indicator |
Installation
The max. operating pressure of the system must not exceed the max. admissible operating pressure of the filter (see name plate). During assembly of the filter (observe the tightening torque), the flow direction (direction arrows) and the required servicing height of the filter element are to be considered. Easy filter element exchange is guaranteed in the installation position filter bowl vertically downwards. The maintenance indicator must be arranged in a well visible way. Remove the plastic plugs in the filter inlet and outlet. Ensure that the system is assembled without tension stress. The optional electric maintenance indicator is connected via the electronic switching element with one or two switching points, which is attached to the mechanical/visual maintenance indicator and held by means of the locking ring.
Commissioning
Commission the system.
Notice:
There is no bleeding provided at the filter.
Maintenance
If at operating temperature, the red indicator pin reaches out of the mechanical/visual maintenance indicator and/or if the switching process in the electronic switching element is triggered, the filter element is contaminated and needs to be replaced and cleaned respectively. The material number of the corresponding replacement filter element is indicated on the name plate of the complete filter. It must comply with the material number on the filter element. Decommission the system. The operating pressure is to be built up on the system side.
Notice:
There is no bleeding provided at the filter.
Via the drain screw (from NG0160 fitted by default), the oil on the dirt side can be drained. Screw off the filter bowl (and/or bottom with NG1000). Remove the filter element from the spigot by rotating it slightly. Clean the filter components, if necessary. Check the seals at the filter bowl for damage and renew them, if necessary. Filter elements made of wire mesh can be cleaned. Install the new or cleaned filter element on the spigot again by slightly rotating it. The filter is to be assembled in reverse order. The torque specifications (“Tightening torques” chapter) are to be observed. Commission the system.
Warning:
Assembly and disassembly only with depressurized system! Filter is under pressure! Remove the filter bowl only if it is depressurized! Do not exchange the maintenance indicator while the filter is under pressure! If the flow direction is not considered during the assembly, the filter element will be destroyed. Particles will get into the system and damage downstream components.
Notice:
All works at the filter only be trained specialists. Functional and safety warranty only applicable when using genuine Bosch Rexroth spare parts! Warranty becomes void if the delivered item is changed by the ordering party or third parties or improperly mounted, installed, maintained, repaired, used or exposed to environmental condition that do not comply with the installation conditions.Notices:
Presentation contains mechanical optical maintenance indicator (1) and electronic switching element (2) (3). Switching elements with increased switching power at request.
Electronic switching elements
WE-.SP
Electronic switching elements
WE-.SP
Operating temperature -30 … +85 °CData sheet
Spare parts & repair
Electronic switching elements
WE-S02
Electronic switching elements
WE-S02
Max. operating pressure 40 bar Operating temperature -10 … +100 °CData sheet
Spare parts & repair
Pressure differential indicators for filters in pressure lines
WO-D01
Pressure differential indicators for filters in pressure lines
WO-D01
Max. operating pressure 450 bar Operating temperature -30 … +100 °CData sheet
Spare parts & repair
Classification according to the Pressure Equipment Directive
These inline filters for hydraulic applications are pressure holding equipment according to article 1, section 2.1.4 of the Pressure Equipment Directive 97/23/EC (PED). However, on the basis of the exception in article 1, section 3.6 of the PEG, hydraulic filters are exempt from the PED if they are not classified higher than category I (guideline 1/19).
For the classification, fluids from the chapter “Compatibility with permitted hydraulic fluids” have been taken into consideration.
They do not receive a CE mark.
Use in potentially explosive areas according to directive 94/9/EC (ATEX)
These inline filters are no equipment or components in the sense of directive 94/9/EC and are not provided with a CE mark. It has been proven with the ignition risk analysis that these inline filters do not have own ignition sources acc. to DIN EN 13463-1:2009.
According to DIN EN 60079-11:2012, the electronic maintenance indicators with one switching point:
WE-1SP-M12x1 and WE-1SP-EN175301-803
are simple, electronic operating equipment not having an own voltage source. This simple, electronic operating equipment may - according to DIN EN 60079-14:2012 - in intrinsically safe electric circuits (Ex ib) be used in systems without marking and certification.
The inline filters and the electronic maintenance indicators described here can be used for the following potentially explosive areas:
Zone suitability |
||
Gas |
1 |
2 |
Dust |
21 |
22 |