Online water content measurement devices allow the water activity in hydraulic and lubricating oils to be monitored online quickly and reliably.

 

Function

The WGMS oil humidity and temperature measurement encoder allows fast and reliable measurement of the humidity content in oils.

The devices are used to monitor humidity in real time and to control dryers and oil conditioners so that they are only activated as needed. Efficient monitoring helps to save oil and is good for the environment. With the WGMS, the humidity content in oil can be monitored simply and cost-effectively.

 

Measurement of the water activity

The WGMS measures the oil humidity in the form of water activity (aw) and also the oil temperature (T). The water activity is a direct indicator of whether there is a risk of water separation as a phase. The measurement is carried out independently of the type, age and temperature of the oil.

 

Calculation of the water content

The WGMS indicates the water activity (aw) and oil temperature (T). It is possible to calculate the average mass concentration of water in oil in ppm using this information. For this purpose, only the oil-specific conversion coefficients have to be determined.

01

02

03

04

WGMS

2

Type

01

Online water content measuring unit

WGMS

Version

02

Standard version consisting of:
- Sensor for the determination of water activity and temperature
- Sensor cable, length 2 m
- Sensor protection (stainless steel mesh)
- Serial interface RS 232 C
- Analog output signal: 4...20 mA
  Channel 1: 0...1
  Channel 2: 0...+100 °C
- Measurement for analog output
  Channel 1: water activity aw
  Channel 2: oil temperature T in °C

4

As version 4, however with sensor cable, length 5 m

5

As version 4, however with sensor cable, length 10 m

6

Power supply

03

24 V

2

Supplementary information

04

Without

no code

Ball valve installation kit

K

Ball valve installation kit

01

02

03

Z

WGM

KHI

01

Accessories

Z

02

Water content measuring unit

WGM

03

Ball valve installation kit

KHI

Material number

Part number

Ball valve installation kit

R928028819

ZWGM-KHI

General

Ambient temperature range

°C

​0 … +60

Storage temperature range 1)

°C

-40 … +65

Mass

kg

≈ 1.5
1) max. relative air humidity 65 %

Measurements

Measuring point

Piping with flows up to 40 bar or turbulent tank installation location

Response time

min

10

Water activity

 

Measurement range

aw

0 ... 1

Measurement accuracy

aw

0 ... 0.9: ±0.02

aw

0.9 ... 1: ±0.03

Sensor

Capacitive thin-film polymer sensor

Temperature

 

Measurement range

°C

0 … 100

Measurement accuracy

°C

± 0.2

Sensor

Pt100

Electrical connections

Analog output

mA

​4 … ​20

Power supply

10 ... 35 VDC, 24 VAC ± 20%

Current consumption 1)

max.

mA

40

Housing protection class

IP65

Sensor protection

Stainless steel grid filter

EMC (electro-magnetic compatibility)

as per EN 61326-1, industr. requirements
1) At +20 °C (UIn 24 VDC) Iout 2 x 0...20 mA

Compatibility with permitted hydraulic fluids

Hydraulic fluid 1)

Mineral oils HLP according to DIN 51524
1) For more information and data on the use of other hydraulic fluids please contact us.

The maximum operating pressure at the selected place of installation must not exceed the permissible operating pressure of the sensor.

When installing the sensor, ensure that the flow velocity does not exceed 1 m/s.

With the optional ball valve installation kit, it is possible to remove or install the sensor during system operation without having to drain the oil.

Electrically connect the sensor.

Important: when using the ball valve installation kit, leaks will occur when removing or inserting the sensor.

Warning

Hot oil can cause burns when removing or inserting the sensor.

 

Note:

All work on the device must be performed by trained specialists only. Warranty becomes void if the delivered item is changed by the ordering party or third parties or improperly mounted, installed, maintained, repaired, used or exposed to environmental condition that do not comply with the installation conditions.