0811405152

Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

BOSCH REXROTH

MATERIAL:  0811405152

SUMMARY:  Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Due to extremely high demand, please call 888-651-5712 for availability

Pressure sensor connection versions

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

01

02

03

04

05

06

07

08

09

10

11

VT-

V

A

R

A

P

1

2X

/

V0

/

01

VT-

02

V

Hydraulic component (control)

03

Axis control

A

Valve type

04

High-response valve

R

Control

05

Analog

A

Function

06

p/Q control

P

Output stages

07

1 output stage

1

Serial number for types

08

2.7 A solenoid

527

3.7 A solenoid

537

09

Component series 20 ... 29 (20 ... 29: unchanged technical data and pin assignment)

2X

Customer version

10

Catalog version

V0

Option

11

High-response valve size 6/10, direct operated

no code

p/Q valve size 10, direct operated

5/3V

High-response valve, pilot-operated

2STV

High-response valve, pilot-operated, control line A → X

3/2V

General

Type / version

VT-VARAP1-527 VT-VARAP1-537

Supply voltage
UB at z2 ‒ b2

nominal 24 V=
battery voltage 21...40 V,
rectified alternating voltage Ueff = 21...28 V
(single-phase, full-wave rectifier)

Smoothing capacitor, separately
at z2 – b2

Recommendation: Capacitor module VT 11110 (see data sheet 30750)
(only necessary if the ripple of UB >10 %)

Valve solenoid, max.

A

2.7 3.7

Current consumption, max. 1)

A

1.7 2.7

Power consumption (typical)

W

37 55

Input signal (command value)

b20: 0...±10 V – differential amplifier
z20: 0...±10 V – differential amplifier
(Ri= 100 kΩ)

Input signal (command value p)

z12: 0...+10 V – differential amplifier
z10: 0 V – differential amplifier

Actual value from the pressure sensor

z14: 4...20 mA – current input
b16: 0...+10 V/1...+6 V – voltage input
b18: 0 V – reference

Pressure controller OFF

b10: 6...40 V=

External enquiry pressure controller active

z24: 24 V/0.1 A max.

Limit frequency

for applications ≤ 30 Hz

Signal source

Potentiometer 10 kΩ
Supply with ±10 V from b32, z32 (10 mA) or external signal source

Enable output stage

at z16, U= 8.5...40 V, Ri = 100 kΩ LED (green) on front plate lights up

Sensor supply

z6: +15 V/35 mA, Ri ~ 25 Ω

Position transducer

Supply

b30: -15 V (25 mA)
z30: +15 V (35 mA)

Pilot control valve

Actual value signal

b22: 0...±10 V, RL = 10 kΩ/Ref. b24

Main stage

Actual value reference

b26: 0...±10 V, RL = 10 kΩ/Ref. b28

Solenoid output
b6 ‒ b8

Clocked current controller

Imax

A

2.7 3.7

Cable lengths between amplifier and valve

Solenoid cable

m

20

m

20 … 60

Number of wires / line cross-section

Position transducer

4 x 0.5 mm2 (shielded)

Pressure sensor

4 x 0.5 mm2 (shielded)

Special features

Cable break protection for actual value cable
Position control with PID behavior
Pulsed output stage
Fast energization and fast deletion for short actuating times
Short-circuit-proof outputs
External controller shut-off

Adjustment

Zero point via trimming potentiometer ±5 %
Command value attenuator Q
Pressure controller KP, KI and KD
Sensitivity pressure load cell
Zero point pressure load cell

LED displays

green

Enable

yellow

Cable break position transducer

red

Supply voltage (UB too low)

yellow

Pressure controller OFF

yellow

Pressure controller working

both yellow LEDs are flashing

Cable break pressure sensor

Error message

Cable break actual value
UB too low
±15 V stabilization

z22: Open collector output to +UB
max. 100 mA; no error: +UB

Plug-in connection

Plug to DIN 41612-F32

Operating temperature

°C

​0 … +70

Storage temperature range

°C

-20 … +70

Weight

m

kg

0.49
1) Current consumption may increase with min. UB and extreme cable lengths to the control solenoid

Power zero b2 and control zero b12 or b14 or z28 must be separately led to the central ground (neutral point).

For applications outside these parameters, please consult us!

a

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

b

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Problem:

P share too small

Solution:

→ Rotate KP against 13 (fine adjustment)

→ P gain >

 

DIL 14

ON

DIL 15

OFF

DIL 16

ON

c

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Problem:

P share too large

Solution:

→ Rotate KP against 0 (fine adjustment)

➝ Use DIL 14–16 to reduce the P gain according to the table

d

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Problem:

P share correct, control deviation too large

Solution:

➝ Increase the I gain share

→ DIL 11 ON = I share = 0

       DIL 12 ON = I share connected

→ Rotate KI against 13

e

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Problem:

Time constant of the I share too low

Solution:

➝ Rotate KI against 13 until control deviation and vibration are perfect

→ If KI = 13 is not sufficient, the P share must also be reduced

f

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Problem:

D share too low

Solution:

➝ Rotate KD against 13

→ D share >

DIL 8

ON

DIL 9

OFF

DIL 10

OFF

Front plate

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Block diagram with pin assignment

0811405152, 0811405153, 0811405154

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Block diagram with pin assignment

0811405155, 0811405156

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Block diagram daughter card

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Mode setting (DIL switch, daughter card)

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

DIL switch

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

HEXCODE switch

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Principle of the control loop

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Example 2

Flow with load compensation controlled via pressure compensator and the pressure regulated in the closed control loop (pressure cut off).

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Example 1

Pressure control in a cylinder chamber for achieving a constant clamping force.

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier

Dimensions in mm

technical illustration-0811405152-Bosch Rexroth
VT-VARAP1-527-20/V0
p/Q closed-loop control amplifier