BOSCH REXROTH
VT-VETSY-1-1X/1-2-1-1-0/USA
R978050422
Controller Test Rigs
Test box
BOSCH REXROTH
MATERIAL: R978050422
SUMMARY: Test box
Quantity in stock: 1
Quantity Details:- Hydrotech Stock: 0 can ship April 22, 2024
- Factory Stock: 1 can ship June 3, 2024
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
|||||||
VT-VETSY-1 |
– |
1X |
/ |
1 |
– |
2 |
– |
1 |
– |
1 |
– |
0 |
/ |
* |
01 |
Service case with test device for proportional servo valves with integrated electronics |
VT-VETSY-1 |
02 |
Component series 10 ... 19 (10 ... 19: unchanged technical data and pin assignment) |
1X |
03 |
Test device type VT-VET-1-1X |
1 |
04 |
Connection cable to valve 2 pieces 6-pole connection cable type VT-VETK-1-1X |
2 |
05 |
Adapter cable for valve type 4WSE2EM6-1X Adapter cable type VT-VETAK-1-1X |
1 |
06 |
Power supply unit 90-264 V AC/+24 V DC; 3,75 A Power supply unit type VT-VETNT-3-1X/G24 |
1 |
07 |
Power supply unit 115 / 220 V/±15 VDC; 0.25 A Without power supply unit (to be ordered separately) |
0 |
08 |
Further details in the plain text |
1) The mains connector of the power supply unit is suitable for sockets in Germany and many European countries. In some countries, a country-specific adapter has to be used. It is not included in the scope of delivery. |
General
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |
Component series |
1X | 1X/G24 | 1X/G15 | 1X | 1X |
Operating voltage
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | ||||
Operating voltage |
Switch “power selector” |
Switching position “24 V” |
UB |
24 V; –20 % +40 % | |||||
Switching position “±15 V” |
UB |
±15 V; ± 10 % | |||||||
Operating voltage |
U |
90 …264 VAC; 47 … 63 Hz | 115 V / 230 V ± 5 % 50/60 Hz switchable | ||||||
Current consumption of the test device |
I |
0,1 A | |||||||
Current consumption |
Imax |
1.2 A | 29 mA | ||||||
Output voltage |
U |
24 VDC ± 1 V; 3,75 A |
+15 VDC ± 0.2 V; 0.25 A –15 VDC ± 0.2 V; 0.25 A |
Inputs
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | ||||
Input connector ES |
Command values at pin E and D |
Ue; Ie |
according to the valve specifications | ||||||
Enable signal at pin C (24 V operation) |
Not active |
UF |
0 … 10 V | ||||||
Active |
UF |
16 V … UB | |||||||
Output socket AB |
Actual value at pin F |
Ue; Ie |
according to the actual value output of the valve | ||||||
BNC socket |
Ue |
0 … ±10 V |
Outputs
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |||||||
Input connector ES |
Actual value at pin F |
Ua; Ia |
according to the actual value output of the valve | |||||||||
Output socket AB |
Enable signal at pin C (24 V operation) |
Switch “setpoint selector” |
Switching position “internal” or “BNC” |
Enable switch “enable” |
In switching position “off” |
UF |
0 V | |||||
In switching position “on” |
UF |
UB | ||||||||||
Switching position “control” |
In switching position “off” |
UF |
0 V | |||||||||
In switching position “on” |
UF |
according to pin C of the input connector ES | ||||||||||
Command values at pin D and E |
Switching position “internal” or “BNC” |
Pin E |
Reference potential | |||||||||
Pin D |
Ucommand |
0 … ±10 V, if Re valve > 500 Ω | ||||||||||
Icommand |
0 … ±20 mA, if Re valve < 500 Ω | |||||||||||
Switching position “control” |
Pin E and D |
Ucommand |
according to the input connector ES (pin E and D) |
Other information
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |||
Fuse |
electronic overload protection | Temperature fuse 130 °C | ||||||
Length of the mains line |
l |
m |
≈ 1.5 | 2 | ||||
Length of the line to the test device |
l |
m |
≈ 1.5 | |||||
Length of the connection cable |
l |
m |
3 | |||||
Connection |
For valve |
Mating connector according to DIN EN 175201-804 | Mating connector VG 95328 | |||||
For test device |
Connector MS3101A 14S 6P | |||||||
Dimensions (W x H x D) |
94 x 54 x 160 mm | 139 x 61 x 36 mm | 86 x 56 x 86 mm | |||||
Weight |
m |
kg |
0.36 | 0.46 | 0.63 | 0.3 |
For applications outside these parameters, please consult us!