Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
VT-VETSY-1-1X/1-2-1-1-0/USA
R978050422
Controller Test Rigs

Test box

$5,887.00

BOSCH REXROTH

MATERIAL:  R978050422

SUMMARY:  Test box

Quantity in stock: 1

Quantity Details:
  • Hydrotech Stock: 0 can ship April 22, 2024
  • Factory Stock: 1 can ship June 3, 2024
Add to Cart

01

02

03

04

05

06

07

08

VT-VETSY-1

1X

/

1

2

1

1

0

/

*

01

Service case with test device for proportional servo valves with integrated electronics

VT-VETSY-1

02

Component series 10 ... 19 (10 ... 19: unchanged technical data and pin assignment)

1X

03

Test device type VT-VET-1-1X

1

04

Connection cable to valve

2 pieces 6-pole connection cable type VT-VETK-1-1X

2

05

Adapter cable for valve type 4WSE2EM6-1X

Adapter cable type VT-VETAK-1-1X

1

06

Power supply unit 90-264 V AC/+24 V DC; 3,75 A

Power supply unit type VT-VETNT-3-1X/G24

1

07

Power supply unit 115 / 220 V/±15 VDC; 0.25 A

Without power supply unit (to be ordered separately)

0

08

Further details in the plain text

1) The mains connector of the power supply unit is suitable for sockets in Germany and many European countries. In some countries, a country-specific adapter has to be used. It is not included in the scope of delivery.

General

Type / version

VT-VET-1 VT-VETNT-3 VT-VETNT-2 VT-VETK-1 Stecker MS3101A 14S 6P

Component series

1X 1X/G24 1X/G15 1X 1X

Operating voltage

Type / version

VT-VET-1 VT-VETNT-3 VT-VETNT-2 VT-VETK-1 Stecker MS3101A 14S 6P

Operating voltage

Switch “power selector”

Switching position “24 V”

UB

24 V; –20 % +40 %

Switching position “±15 V”

UB

±15 V; ± 10 %

Operating voltage

U

90 …264 VAC; 47 … 63 Hz 115 V / 230 V ± 5 % 50/60 Hz switchable

Current consumption of the test device

I

0,1 A

Current consumption

Imax

1.2 A 29 mA

Output voltage

U

24 VDC ± 1 V; 3,75 A +15 VDC ± 0.2 V; 0.25 A
–15 VDC ± 0.2 V; 0.25 A

Inputs

Type / version

VT-VET-1 VT-VETNT-3 VT-VETNT-2 VT-VETK-1 Stecker MS3101A 14S 6P

Input connector ES

Command values at pin E and D

Ue; Ie

according to the valve specifications

Enable signal at pin C (24 V operation)

Not active

UF

0 … 10 V

Active

UF

16 V … UB

Output socket AB

Actual value at pin F

Ue; Ie

according to the actual value output of the valve

BNC socket

Ue

0 … ±10 V

Outputs

Type / version

VT-VET-1 VT-VETNT-3 VT-VETNT-2 VT-VETK-1 Stecker MS3101A 14S 6P

Input connector ES

Actual value at pin F

Ua; Ia

according to the actual value output of the valve

Output socket AB

Enable signal at pin C (24 V operation)

Switch “setpoint selector”

Switching position “internal” or “BNC”

Enable switch “enable”

In switching position “off”

UF

0 V

In switching position “on”

UF

UB

Switching position “control”

In switching position “off”

UF

0 V

In switching position “on”

UF

according to pin C of the input connector ES

Command values at pin D and E

Switching position “internal” or “BNC”

Pin E

Reference potential

Pin D

Ucommand

0 … ±10 V, if Re valve > 500 Ω

Icommand

0 … ±20 mA, if Re valve < 500 Ω

Switching position “control”

Pin E and D

Ucommand

according to the input connector ES (pin E and D)

Other information

Type / version

VT-VET-1 VT-VETNT-3 VT-VETNT-2 VT-VETK-1 Stecker MS3101A 14S 6P

Fuse

electronic overload protection Temperature fuse 130 °C

Length of the mains line

l

m

≈ 1.5 2

Length of the line to the test device

l

m

≈ 1.5

Length of the connection cable

l

m

3

Connection

For valve

Mating connector according to DIN EN 175201-804 Mating connector VG 95328

For test device

Connector MS3101A 14S 6P

Dimensions (W x H x D)

94 x 54 x 160 mm 139 x 61 x 36 mm 86 x 56 x 86 mm

Weight

m

kg

0.36 0.46 0.63 0.3

For applications outside these parameters, please consult us!