BOSCH REXROTH
R978050422
$5,934.10 USD
- BOSCH REXROTH
- Material:R978050422
- Model:VT-VETSY-1-1X/1-2-1-1-0/USA
Quantity in stock: 0
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
|||||||
|
VT-VETSY-1 |
– |
1X |
/ |
1 |
– |
2 |
– |
1 |
– |
1 |
– |
0 |
/ |
* |
|
01 |
Service case with test device for proportional servo valves with integrated electronics |
VT-VETSY-1 |
|
02 |
Component series 10 ... 19 (10 ... 19: unchanged technical data and pin assignment) |
1X |
|
03 |
Test device type VT-VET-1-1X |
1 |
|
04 |
Connection cable to valve 2 pieces 6-pole connection cable type VT-VETK-1-1X |
2 |
|
05 |
Adapter cable for valve type 4WSE2EM6-1X Adapter cable type VT-VETAK-1-1X |
1 |
|
06 |
Power supply unit 90-264 V AC/+24 V DC; 3,75 A Power supply unit type VT-VETNT-3-1X/G24 |
1 |
|
07 |
Power supply unit 115 / 220 V/±15 VDC; 0.25 A Without power supply unit (to be ordered separately) |
0 |
|
08 |
Further details in the plain text |
|
| 1) The mains connector of the power supply unit is suitable for sockets in Germany and many European countries. In some countries, a country-specific adapter has to be used. It is not included in the scope of delivery. |
General
|
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |
|
Component series |
1X | 1X/G24 | 1X/G15 | 1X | 1X |
Operating voltage
|
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | ||||
|
Operating voltage |
Switch “power selector” |
Switching position “24 V” |
UB |
24 V; –20 % +40 % | |||||
|
Switching position “±15 V” |
UB |
±15 V; ± 10 % | |||||||
|
Operating voltage |
U |
90 …264 VAC; 47 … 63 Hz | 115 V / 230 V ± 5 % 50/60 Hz switchable | ||||||
|
Current consumption of the test device |
I |
0,1 A | |||||||
|
Current consumption |
Imax |
1.2 A | 29 mA | ||||||
|
Output voltage |
U |
24 VDC ± 1 V; 3,75 A |
+15 VDC ± 0.2 V; 0.25 A –15 VDC ± 0.2 V; 0.25 A |
||||||
Inputs
|
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | ||||
|
Input connector ES |
Command values at pin E and D |
Ue; Ie |
according to the valve specifications | ||||||
|
Enable signal at pin C (24 V operation) |
Not active |
UF |
0 … 10 V | ||||||
|
Active |
UF |
16 V … UB | |||||||
|
Output socket AB |
Actual value at pin F |
Ue; Ie |
according to the actual value output of the valve | ||||||
|
BNC socket |
Ue |
0 … ±10 V | |||||||
Outputs
|
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |||||||
|
Input connector ES |
Actual value at pin F |
Ua; Ia |
according to the actual value output of the valve | |||||||||
|
Output socket AB |
Enable signal at pin C (24 V operation) |
Switch “setpoint selector” |
Switching position “internal” or “BNC” |
Enable switch “enable” |
In switching position “off” |
UF |
0 V | |||||
|
In switching position “on” |
UF |
UB | ||||||||||
|
Switching position “control” |
In switching position “off” |
UF |
0 V | |||||||||
|
In switching position “on” |
UF |
according to pin C of the input connector ES | ||||||||||
|
Command values at pin D and E |
Switching position “internal” or “BNC” |
Pin E |
Reference potential | |||||||||
|
Pin D |
Ucommand |
0 … ±10 V, if Re valve > 500 Ω | ||||||||||
|
Icommand |
0 … ±20 mA, if Re valve < 500 Ω | |||||||||||
|
Switching position “control” |
Pin E and D |
Ucommand |
according to the input connector ES (pin E and D) | |||||||||
Other information
|
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |||
|
Fuse |
electronic overload protection | Temperature fuse 130 °C | ||||||
|
Length of the mains line |
l |
m |
≈ 1.5 | 2 | ||||
|
Length of the line to the test device |
l |
m |
≈ 1.5 | |||||
|
Length of the connection cable |
l |
m |
3 | |||||
|
Connection |
For valve |
Mating connector according to DIN EN 175201-804 | Mating connector VG 95328 | |||||
|
For test device |
Connector MS3101A 14S 6P | |||||||
|
Dimensions (W x H x D) |
94 x 54 x 160 mm | 139 x 61 x 36 mm | 86 x 56 x 86 mm | |||||
|
Weight |
m |
kg |
0.36 | 0.46 | 0.63 | 0.3 | ||
For applications outside these parameters, please consult us!