***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQIFLANEX (XQIFLANEX) is a sophisticated valve assembly designed for efficient accumulator charging using a fixed displacement pump. This assembly operates by unloading the pump when the pressure reaches the valve's set point and re-engaging it once the pressure falls to a predetermined level, based on the pilot valve's fixed percentage. A dual-function ventable relief acts as both a main stage for pump unloading and as an overpressure relief system. The assembly also features a simple circuit that smooths out the pump's unloading process. To ensure optimal performance, it requires a separate drain line to mitigate erratic behavior due to tank line pressure fluctuations. When implementing this assembly, selecting an appropriate adjustment range is crucial since low operating pressures and differentials can lead to narrow bands between unload and reset points, demanding precise system design. High flow rates may cause significant pressure drops, impacting the differential available for operation. The pressure settings are based on port 1 of the QPA pilot valve, with pump and accumulator pressures affected by flow-induced drops. The assembly's large porting relative to its capacity encourages using large piping to minimize flow-induced pressure drop issues. Its spool design maintains a consistent differential ratio due to non-wearing diameters. It is important that the accumulator pilot valve be set below any system reliefs to prevent overheating. This package's relief function serves as an overpressure device, preset higher than any pilot valve settings and sealed for security. With a capacity of 80 gpm (320 L/min), this line-mounted body type features three mounting holes with .375-16 UNC 2B threads and depths of .88 inches (22.4 mm).

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity80 gpm320 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.88 in.22,4 mm
Mounting Hole Quantity33

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.