You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQIFLANCY


$1,543.60 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQIFLANCY
  • Model:XQIF-LAN-CY
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQIFLANCY (XQIFLANCY) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly ensures optimal system performance by unloading the pump once the pressure reaches a predetermined set point and reactivating it when the pressure falls to a specific level, as determined by the pilot valve's fixed percentage. A key feature of this assembly is its ventable relief, which functions both as a main stage for unloading the pump and as an overpressure relief mechanism. Additionally, it includes a simple circuit that softens the unloading process of the pump, enhancing operational smoothness. For effective application, it is crucial to install a separate drain line to prevent erratic operations caused by fluctuations in tank line pressure. The assembly's design emphasizes careful selection of adjustment ranges due to potential impacts from system pressure drops and flow rates on unloading valve operations. Notably, low operating pressures paired with low differentials can create narrow bands between unload and reset points, necessitating precise system design. Furthermore, high flow rates may result in significant pressure drops that reduce the differential available for valve operation. The XQIFLANCY assembly is characterized by its large porting relative to capacity, encouraging the use of large piping to minimize issues from flow-induced pressure drops. Its pilot valve spool design maintains a fixed differential ratio through diameters on the spool that resist wear over time. For optimal performance and safety, ensure that the accumulator pilot valve is set below any reliefs on the pump side of the system to avoid severe heating issues. The relief component serves as an overpressure device set higher than any pilot valve settings and comes capped for security.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity80 gpm320 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.88 in.22,4 mm
Mounting Hole Quantity33

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.