You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQIFLANCX


$1,543.60 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQIFLANCX
  • Model:XQIF-LAN-CX
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQIFLANCX (XQIFLANCX) is a sophisticated valve assembly designed for charging accumulators using a fixed displacement pump. This unit effectively manages pressure by unloading the pump when it reaches a predetermined set point and re-engaging it when the pressure drops to a specified level, as determined by the pilot valve's fixed percentage. The ventable relief feature serves dual purposes: it acts as a main stage to unload the pump and provides system overpressure relief. Additionally, this assembly incorporates a circuit that softens pump unloading, enhancing operational smoothness. For optimal performance, it's crucial to implement a separate drain line to mitigate erratic operations due to tank line pressure fluctuations. When selecting an adjustment range, careful consideration of system pressure drops and flow rates is essential. Low operating pressures with narrow differentials demand precise system design, while high flow rates typically result in significant pressure drops affecting the valve's differential capacity. The pressure settings are relative to the QPA pilot valve's port 1 area; hence, actual pump and accumulator pressures may vary due to flow-induced pressure drops. The assembly features large porting relative to its capacity, encouraging the use of large piping to minimize flow-induced pressure drop issues. Its spool design ensures consistent differential ratios as it relies on diameters that do not wear or change over time. Notably, the accumulator pilot valve must be configured below any system reliefs on the pump side to prevent excessive heating. This package\u2019s overpressure relief is set higher than any pilot valve settings and capped for safety. With an 80 gpm (320 L/min) capacity and line mount body type, this assembly requires three mounting holes threaded at .375-16 UNC - 2B with a depth of .88 inches (22.4 mm).

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity80 gpm320 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.88 in.22,4 mm
Mounting Hole Quantity33

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.