SUN HYDRAULICS
XQIFLANCE
$1,545.50 USD
Tags:
- SUN HYDRAULICS
- Material:XQIFLANCE
- Model:XQIF-LAN-CE
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQIFLANCE (Material Number: XQIFLANCE) is an advanced valve assembly specifically designed for charging accumulators using a fixed displacement pump. This assembly efficiently manages system pressure by unloading the pump when a set pressure point is reached and re-engaging it when the pressure drops to a predetermined level. The ventable relief valve within this assembly serves dual functions: it acts as both a main stage for unloading the pump and as an overpressure relief for the system. Additionally, the assembly features a simple circuit that softens the unloading process, enhancing operational smoothness. A separate drain line is essential for installation to avoid erratic operation due to tank line pressure fluctuations. It is critical to select an appropriate adjustment range, as system pressure drops and flow rates can significantly impact unloading valve performance. Low operating pressures combined with minimal differentials require precise system design due to a narrow band between unload and reset points. High flow rates may result in substantial pressure drops, affecting the differential available for valve operation. The design incorporates large porting relative to capacity, encouraging large piping use to minimize issues from flow-induced pressure drops. The pilot valve's spool design maintains a fixed differential ratio through non-wearing diameters on the spool, ensuring consistent performance over time. It is crucial that the accumulator pilot valve setting remains below any reliefs on the pump side of the system to prevent excessive heating. This package's relief component functions strictly as an overpressure device, preset higher than any pilot valve settings and capped for security. The assembly has a capacity of 80 gpm (320 L/min) and is line-mounted with specific mounting hole requirements detailed in its specifications.
The Sun Hydraulics XQIFLANCE (Material Number: XQIFLANCE) is an advanced valve assembly specifically designed for charging accumulators using a fixed displacement pump. This assembly efficiently manages system pressure by unloading the pump when a set pressure point is reached and re-engaging it when the pressure drops to a predetermined level. The ventable relief valve within this assembly serves dual functions: it acts as both a main stage for unloading the pump and as an overpressure relief for the system. Additionally, the assembly features a simple circuit that softens the unloading process, enhancing operational smoothness. A separate drain line is essential for installation to avoid erratic operation due to tank line pressure fluctuations. It is critical to select an appropriate adjustment range, as system pressure drops and flow rates can significantly impact unloading valve performance. Low operating pressures combined with minimal differentials require precise system design due to a narrow band between unload and reset points. High flow rates may result in substantial pressure drops, affecting the differential available for valve operation. The design incorporates large porting relative to capacity, encouraging large piping use to minimize issues from flow-induced pressure drops. The pilot valve's spool design maintains a fixed differential ratio through non-wearing diameters on the spool, ensuring consistent performance over time. It is crucial that the accumulator pilot valve setting remains below any reliefs on the pump side of the system to prevent excessive heating. This package's relief component functions strictly as an overpressure device, preset higher than any pilot valve settings and capped for security. The assembly has a capacity of 80 gpm (320 L/min) and is line-mounted with specific mounting hole requirements detailed in its specifications.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 80 gpm320 L/min. |
| Body Type | Line mountLine mount |
| Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
| Mounting Hole Depth | .88 in.22,4 mm |
| Mounting Hole Quantity | 33 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.