***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANDP (XQGELANDP) is a sophisticated valve assembly designed to efficiently manage the charging of an accumulator using a fixed displacement pump. This system automatically unloads the pump when the pressure reaches a predetermined set point, and re-engages it when the pressure drops to a value determined by the fixed percentage of the pilot valve, ensuring optimal accumulator recharge. The ventable relief valve serves dual functions: unloading the pump and acting as an overpressure safety device for the system. A separate drain line is essential for this assembly to prevent erratic operations due to fluctuations in tank line pressure. When selecting this assembly, careful attention should be paid to adjustment ranges, as low operating pressures and low differentials can create narrow bands between unload and reset pressures, necessitating precise system design. High flow rates may lead to significant pressure drops, impacting differential management by the valve. The pressure setting references port 1 area of the QPA pilot valve, with inherent differences in pump and accumulator pressures due to flow-induced drops. The assembly features large porting relative to its capacity, encouraging large piping use to minimize flow-induced pressure drop issues. The spool design of the pilot valve maintains a fixed differential ratio due to its durable construction that resists wear over time. It's crucial that the accumulator pilot valve is set below any reliefs on the pump side to avoid severe heating. The relief in this package acts as an overpressure device set higher than any pilot valve settings and is capped for safety. With a capacity of 40 gpm (160 L/min) and designed for line mounting, this assembly offers robust performance for demanding hydraulic applications.
The Sun Hydraulics XQGELANDP (XQGELANDP) is a sophisticated valve assembly designed to efficiently manage the charging of an accumulator using a fixed displacement pump. This system automatically unloads the pump when the pressure reaches a predetermined set point, and re-engages it when the pressure drops to a value determined by the fixed percentage of the pilot valve, ensuring optimal accumulator recharge. The ventable relief valve serves dual functions: unloading the pump and acting as an overpressure safety device for the system. A separate drain line is essential for this assembly to prevent erratic operations due to fluctuations in tank line pressure. When selecting this assembly, careful attention should be paid to adjustment ranges, as low operating pressures and low differentials can create narrow bands between unload and reset pressures, necessitating precise system design. High flow rates may lead to significant pressure drops, impacting differential management by the valve. The pressure setting references port 1 area of the QPA pilot valve, with inherent differences in pump and accumulator pressures due to flow-induced drops. The assembly features large porting relative to its capacity, encouraging large piping use to minimize flow-induced pressure drop issues. The spool design of the pilot valve maintains a fixed differential ratio due to its durable construction that resists wear over time. It's crucial that the accumulator pilot valve is set below any reliefs on the pump side to avoid severe heating. The relief in this package acts as an overpressure device set higher than any pilot valve settings and is capped for safety. With a capacity of 40 gpm (160 L/min) and designed for line mounting, this assembly offers robust performance for demanding hydraulic applications.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 40 gpm160 L/min. |
| Body Type | Line mountLine mount |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.