***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANDN (Material Number: XQGELANDN) is a sophisticated valve assembly designed for efficiently charging an accumulator using a fixed displacement pump. This assembly operates by unloading the pump when the pressure reaches a predetermined set point, and reactivating it when the pressure falls to a specific value dictated by the pilot valve's fixed percentage. The ventable relief in this system serves dual purposes: it acts as a main stage for unloading the pump and functions as an overpressure relief mechanism for the system. For optimal performance, a separate drain line is essential to prevent erratic operation caused by pressure fluctuations in the tank line. It is crucial to select an appropriate adjustment range, as low operating pressures combined with narrow differentials can lead to precise system design requirements. High flow rates can result in significant pressure drops, impacting the valve's differential capacity. The pressure settings are referenced to port 1 of the QPA pilot valve, with pump and accumulator pressures varying due to flow-induced pressure drops. The assembly features large porting relative to its capacity, encouraging the use of sizable piping to minimize issues from flow-induced pressure drops. The spool design of the pilot valve ensures a consistent differential ratio, maintaining durability over time without wear-related changes. It is important that the accumulator pilot valve be set below any reliefs on the pump side to avoid excessive heating. This package includes an overpressure relief device set higher than any pilot valve settings and capped for safety. With a capacity of 40 gpm (160 L/min) and designed for line mounting, this robust assembly offers reliable performance in hydraulic systems requiring precise control of accumulator charging processes.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity40 gpm160 L/min.
Body TypeLine mountLine mount

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.