***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANDM (Material Number: XQGELANDM) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly is engineered to unload the pump when the pressure reaches a pre-set point, and re-engage it once the pressure drops to a value determined by the pilot valve's fixed percentage. It features a ventable relief that serves dual functions: acting as a main stage for unloading the pump and providing system overpressure relief. A separate drain line is necessary to prevent erratic operations due to tank line pressure fluctuations. When selecting an adjustment range, it is crucial to consider system pressure drops and flows, as they can impact unloading valve operations. Low operating pressures combined with low differentials require precise system design due to the narrow band between unload and reset points. High flow rates may lead to significant pressure drops, affecting the valve's differential capabilities. The pressure settings are referenced at port 1 of the QPA pilot valve, with pump pressure being higher and accumulator pressure lower due to flow-induced pressure drops. The assembly's large porting encourages using large piping to minimize flow-induced issues. Its spool design ensures a consistent differential ratio by maintaining constant diameters on the spool that resist wear over time. The accumulator pilot valve must be set below any reliefs in the pump side of the system to avoid severe heating issues. Additionally, the relief device in this package acts as an overpressure mechanism, set higher than any pilot valve setting and capped for security. With a capacity of 40 gpm (160 L/min), this line-mount assembly provides reliable performance in hydraulic systems requiring precise control of accumulator charging cycles.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity40 gpm160 L/min.
Body TypeLine mountLine mount

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.