***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANCO (XQGELANCO) is a valve assembly designed to efficiently manage the charging of an accumulator using a fixed displacement pump. This assembly operates by unloading the pump once the pressure reaches a predetermined set point, and re-engaging it when the pressure drops to a specific value, as determined by the pilot valve's fixed percentage. The ventable relief within this assembly serves dual functions: it acts as a main stage for unloading the pump and also provides system overpressure relief. For optimal performance, it's crucial to install a separate drain line to avoid erratic operation due to tank line pressure fluctuations. When selecting an adjustment range, careful consideration is necessary as system pressure drops and flow rates can impact unloading valve operations. Specifically, low operating pressures combined with low differentials necessitate precise system design due to the narrow band between unload and reset points. Additionally, high flow rates may lead to significant pressure drops that reduce the differential available for valve operation. The pressure settings reference port 1 of the QPA pilot valve; thus, actual pump and accumulator pressures may vary due to flow-induced pressure drops. This assembly features large porting relative to its capacity, encouraging larger piping use to mitigate flow-induced pressure drop issues. The spool design of the pilot valve maintains a consistent differential ratio through non-wearing diameters on its spool, ensuring long-term reliability. It is essential that the accumulator pilot valve is set below any system reliefs on the pump side to prevent excessive heating. The relief in this package functions as an overpressure device, set higher than any pilot valve setting and sealed accordingly.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity40 gpm160 L/min.
Body TypeLine mountLine mount

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.