***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANCN (Material Number: XQGELANCN) is a valve assembly designed for charging an accumulator using a fixed displacement pump. This assembly efficiently manages the pressure cycle by unloading the pump when the system reaches a predetermined pressure set point and re-engaging it when the pressure drops to a specified level, determined by the pilot valve's fixed percentage. The ventable relief valve serves as both the main stage for unloading the pump and as a safeguard against system overpressure. For optimal performance, it is essential to include a separate drain line to mitigate erratic operation due to tank line pressure fluctuations. When deploying this assembly, careful consideration of adjustment ranges is crucial, as low operating pressures and differentials can result in narrow bands between unload and reset points, necessitating precise system design. High flow rates typically lead to significant pressure drops, affecting the differential available for valve operation. The spool design of the pilot valve ensures a consistent differential ratio by utilizing diameters on the spool that resist wear and change over time. It is critical that the accumulator pilot valve be set below any reliefs on the pump side of the system to prevent potential overheating. This assembly features large porting relative to its capacity, encouraging large piping usage to minimize flow-induced pressure drop issues. The relief component functions as an overpressure device, capped at settings higher than those of the pilot valve. With a capacity of 40 gpm (160 L/min) and designed for line mounting, this component is suitable for systems requiring precise control over hydraulic flow and pressure management.
The Sun Hydraulics XQGELANCN (Material Number: XQGELANCN) is a valve assembly designed for charging an accumulator using a fixed displacement pump. This assembly efficiently manages the pressure cycle by unloading the pump when the system reaches a predetermined pressure set point and re-engaging it when the pressure drops to a specified level, determined by the pilot valve's fixed percentage. The ventable relief valve serves as both the main stage for unloading the pump and as a safeguard against system overpressure. For optimal performance, it is essential to include a separate drain line to mitigate erratic operation due to tank line pressure fluctuations. When deploying this assembly, careful consideration of adjustment ranges is crucial, as low operating pressures and differentials can result in narrow bands between unload and reset points, necessitating precise system design. High flow rates typically lead to significant pressure drops, affecting the differential available for valve operation. The spool design of the pilot valve ensures a consistent differential ratio by utilizing diameters on the spool that resist wear and change over time. It is critical that the accumulator pilot valve be set below any reliefs on the pump side of the system to prevent potential overheating. This assembly features large porting relative to its capacity, encouraging large piping usage to minimize flow-induced pressure drop issues. The relief component functions as an overpressure device, capped at settings higher than those of the pilot valve. With a capacity of 40 gpm (160 L/min) and designed for line mounting, this component is suitable for systems requiring precise control over hydraulic flow and pressure management.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 40 gpm160 L/min. |
| Body Type | Line mountLine mount |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.