***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANBE (Material Number: XQGELANBE) is a valve assembly designed specifically for charging accumulators using a fixed displacement pump. This unit operates by unloading the pump once the set pressure point is achieved and reactivating it when pressure drops to a predetermined level, ensuring efficient accumulator recharge. The ventable relief feature serves dual functions: it acts as the main stage for unloading the pump and provides system overpressure relief. For optimal performance, a separate drain line is necessary to avoid erratic behavior due to tank line pressure fluctuations. Users must carefully select an adjustment range, as low operating pressures and differentials require precise system design to maintain stability between unload and reset states. High flow rates can result in significant pressure drops, affecting valve operation. The valve's pressure setting and reseat pressures are based on the QPA pilot valve's port 1 area, with variations in pump and accumulator pressures due to flow-induced drops. Featuring large porting relative to its capacity, this design encourages the use of larger piping to minimize flow-induced pressure issues. The spool design of the pilot valve maintains a fixed differential ratio, ensuring consistent performance over time without wear-induced changes. It is essential that the accumulator pilot valve be set below any reliefs on the pump side to prevent excessive heating. The included overpressure relief device is preset higher than the pilot valve's maximum setting and capped for safety. This assembly has a capacity of 40 gpm (160 L/min) and is intended for line mount applications, providing reliable performance in hydraulic systems requiring precise control of accumulator charging cycles.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity40 gpm160 L/min.
Body TypeLine mountLine mount

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.