SUN HYDRAULICS
XQGELANB5
$822.50 USD
Tags:
- SUN HYDRAULICS
- Material:XQGELANB5
- Model:XQGE-LAN-B5
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANB5 (Material Number: XQGELANB5) is a valve assembly specifically designed to efficiently charge an accumulator using a fixed displacement pump. When the system pressure reaches the valve's set point, the pump is unloaded to prevent over-pressurization and conserve energy. Conversely, when the pressure drops below a predetermined threshold, dictated by the pilot valve's fixed percentage, the pump is re-engaged to recharge the accumulator. This dual-purpose ventable relief valve acts as both a main stage for unloading the pump and an overpressure relief mechanism for the system. For optimal performance, it's important to incorporate a separate drain line in this assembly to mitigate erratic operations caused by fluctuations in tank line pressure. Selecting an appropriate adjustment range is crucial, as low operating pressures combined with minimal differentials can result in a narrow band between unloading and reset points, demanding precise system design considerations. High flow rates typically lead to increased pressure drops that could affect valve operation. The pressure settings and resultant reseat pressures are based on port 1 of the QPA pilot valve, meaning that actual pump pressures will be higher while accumulator pressures will be lower due to flow-induced pressure drops. The assembly features large porting relative to its capacity, encouraging the use of larger piping to minimize flow-induced issues. The spool design of this pilot valve maintains a fixed differential ratio due to its non-wearing diameter areas. It\u2019s critical that the accumulator pilot valve is set below any reliefs on the pump side of the system to prevent excessive heating. The integrated relief within this package functions as an overpressure device and is capped at settings higher than those of any pilot valves in use. This assembly has a capacity of 40 gpm (160 L/min) and is designed for line mount applications.
The Sun Hydraulics XQGELANB5 (Material Number: XQGELANB5) is a valve assembly specifically designed to efficiently charge an accumulator using a fixed displacement pump. When the system pressure reaches the valve's set point, the pump is unloaded to prevent over-pressurization and conserve energy. Conversely, when the pressure drops below a predetermined threshold, dictated by the pilot valve's fixed percentage, the pump is re-engaged to recharge the accumulator. This dual-purpose ventable relief valve acts as both a main stage for unloading the pump and an overpressure relief mechanism for the system. For optimal performance, it's important to incorporate a separate drain line in this assembly to mitigate erratic operations caused by fluctuations in tank line pressure. Selecting an appropriate adjustment range is crucial, as low operating pressures combined with minimal differentials can result in a narrow band between unloading and reset points, demanding precise system design considerations. High flow rates typically lead to increased pressure drops that could affect valve operation. The pressure settings and resultant reseat pressures are based on port 1 of the QPA pilot valve, meaning that actual pump pressures will be higher while accumulator pressures will be lower due to flow-induced pressure drops. The assembly features large porting relative to its capacity, encouraging the use of larger piping to minimize flow-induced issues. The spool design of this pilot valve maintains a fixed differential ratio due to its non-wearing diameter areas. It\u2019s critical that the accumulator pilot valve is set below any reliefs on the pump side of the system to prevent excessive heating. The integrated relief within this package functions as an overpressure device and is capped at settings higher than those of any pilot valves in use. This assembly has a capacity of 40 gpm (160 L/min) and is designed for line mount applications.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 40 gpm160 L/min. |
| Body Type | Line mountLine mount |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.