SUN HYDRAULICS
XQGELANA5
$835.70 USD
Tags:
- SUN HYDRAULICS
- Material:XQGELANA5
- Model:XQGE-LAN-A5
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQGELANA5 (Material Number: XQGELANA5) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This system is engineered to automatically unload the pump when the pressure reaches a predefined set point and re-engage it when the pressure drops, as determined by the pilot valve's fixed percentage. The ventable relief valve serves dual functions: unloading the pump as a main stage and acting as an overpressure relief for the system. A separate drain line is essential in this setup to prevent erratic operations due to tank line pressure fluctuations. When selecting this assembly, it is crucial to choose an appropriate adjustment range since low operating pressures combined with low differentials create a narrow band between unload and reset, necessitating precise system design. High flow rates can result in significant pressure drops, affecting the differential available for operation. The pressure settings refer to port 1 of the QPA pilot valve; thus, actual pump and accumulator pressures may vary due to flow-induced pressure drops. The assembly features large porting relative to its capacity, encouraging the use of large piping to mitigate issues caused by flow-induced pressure drop. The spool design within the pilot valve maintains a fixed differential ratio due to non-wearing diameters on the spool, ensuring consistent performance over time. It is important that any accumulator pilot valve settings are below reliefs on the pump side of the system to avoid overheating issues. This package includes an overpressure relief set higher than any pilot valve setting and capped for safety purposes. With a capacity of 40 gpm (160 L/min) and designed for line mount applications, this assembly offers robust performance in hydraulic systems requiring precise accumulator charging control.
The Sun Hydraulics XQGELANA5 (Material Number: XQGELANA5) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This system is engineered to automatically unload the pump when the pressure reaches a predefined set point and re-engage it when the pressure drops, as determined by the pilot valve's fixed percentage. The ventable relief valve serves dual functions: unloading the pump as a main stage and acting as an overpressure relief for the system. A separate drain line is essential in this setup to prevent erratic operations due to tank line pressure fluctuations. When selecting this assembly, it is crucial to choose an appropriate adjustment range since low operating pressures combined with low differentials create a narrow band between unload and reset, necessitating precise system design. High flow rates can result in significant pressure drops, affecting the differential available for operation. The pressure settings refer to port 1 of the QPA pilot valve; thus, actual pump and accumulator pressures may vary due to flow-induced pressure drops. The assembly features large porting relative to its capacity, encouraging the use of large piping to mitigate issues caused by flow-induced pressure drop. The spool design within the pilot valve maintains a fixed differential ratio due to non-wearing diameters on the spool, ensuring consistent performance over time. It is important that any accumulator pilot valve settings are below reliefs on the pump side of the system to avoid overheating issues. This package includes an overpressure relief set higher than any pilot valve setting and capped for safety purposes. With a capacity of 40 gpm (160 L/min) and designed for line mount applications, this assembly offers robust performance in hydraulic systems requiring precise accumulator charging control.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 40 gpm160 L/min. |
| Body Type | Line mountLine mount |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.