SUN HYDRAULICS
XQEJLANED
$860.80 USD
Tags:
- SUN HYDRAULICS
- Material:XQEJLANED
- Model:XQEJ-LAN-ED
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANED (XQEJLANED) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly features a ventable priority flow control valve that optimizes the pump flow for system use once the pressure reaches the valve's set point. When pressure drops, the priority flow recharges the accumulator, ensuring only necessary flow is directed to it, while excess pump flow remains available for other system needs. The assembly includes a simple circuit to soften pump unloading and an overpressure relief system, enhancing operational reliability. For optimal performance, it requires a separate drain line to prevent erratic operations due to tank line pressure fluctuations. Users should carefully select an adjustment range since system pressure drops and flows can impact unloading valve operation. Low operating pressures with narrow differentials necessitate precise design considerations, while high flow rates may cause significant pressure drops affecting differential operation. The spool design of the pilot valve maintains a fixed differential ratio due to its non-wearing diameters. The assembly's large porting encourages the use of substantial piping, minimizing issues from flow-induced pressure drop. The accumulator pilot valve must be set below any system-side reliefs to avoid excessive heat generation. Additionally, this package's relief acts as an overpressure device set higher than the pilot valve's maximum setting and is capped for safety. Designed for 15 gpm (60 L/min) capacity, this line-mounted assembly uses 6061 aluminum known for its corrosion resistance and strength without anodizing treatment. It has mounting hole threads of .375-16 UNC 2B in., with depths of .88 in., and is equipped with two mounting holes for secure installation.
The Sun Hydraulics XQEJLANED (XQEJLANED) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly features a ventable priority flow control valve that optimizes the pump flow for system use once the pressure reaches the valve's set point. When pressure drops, the priority flow recharges the accumulator, ensuring only necessary flow is directed to it, while excess pump flow remains available for other system needs. The assembly includes a simple circuit to soften pump unloading and an overpressure relief system, enhancing operational reliability. For optimal performance, it requires a separate drain line to prevent erratic operations due to tank line pressure fluctuations. Users should carefully select an adjustment range since system pressure drops and flows can impact unloading valve operation. Low operating pressures with narrow differentials necessitate precise design considerations, while high flow rates may cause significant pressure drops affecting differential operation. The spool design of the pilot valve maintains a fixed differential ratio due to its non-wearing diameters. The assembly's large porting encourages the use of substantial piping, minimizing issues from flow-induced pressure drop. The accumulator pilot valve must be set below any system-side reliefs to avoid excessive heat generation. Additionally, this package's relief acts as an overpressure device set higher than the pilot valve's maximum setting and is capped for safety. Designed for 15 gpm (60 L/min) capacity, this line-mounted assembly uses 6061 aluminum known for its corrosion resistance and strength without anodizing treatment. It has mounting hole threads of .375-16 UNC 2B in., with depths of .88 in., and is equipped with two mounting holes for secure installation.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
Capacity | 15 gpm60 L/min. |
Body Type | Line mountLine mount |
Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
Mounting Hole Depth | .88 in.22,4 mm |
Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.