SUN HYDRAULICS
XQEJLANDK
$807.60 USD
Tags:
- SUN HYDRAULICS
- Material:XQEJLANDK
- Model:XQEJ-LAN-DK
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANDK (XQEJLANDK) is a specialized valve assembly designed for efficiently charging an accumulator using a fixed displacement pump. This assembly integrates a ventable priority flow control valve that optimizes pump flow distribution. When the system pressure reaches the preset level, the priority flow control valve vents, allowing all pump flow to be available to the system. Conversely, when pressure drops according to a fixed percentage of the pilot valve, it redirects priority flow for recharging the accumulator, while leaving remaining pump flow accessible to the system. Notable features include a circuit that softens pump unloading and an overpressure relief mechanism to safeguard against excessive pressures. For optimal application, ensure a separate drain line is installed to prevent erratic operation from tank line pressure fluctuations. Selection of an appropriate adjustment range is crucial as system pressure drops and flows can affect unloading valve performance. Low operating pressures with narrow differentials necessitate precise design due to minimal unload-reset bands, while high flow rates induce significant pressure drops affecting differential management. The assembly's porting is intentionally large relative to its capacity, promoting large piping use to minimize issues from flow-induced pressure drops. The spool design of the pilot valve maintains a consistent differential ratio by utilizing non-wearing diameters on the spool. It\u2019s important that accumulator pilot valves are set below any system-side reliefs to avoid severe heating issues. This package's relief feature functions as an overpressure device set higher than any pilot valve setting and remains capped for safety assurance. The Sun Hydraulics XQEJLANDK is capable of handling capacities up to 15 gpm (60 L/min) and employs a line mount body type with specific mounting hole dimensions for secure installation.
The Sun Hydraulics XQEJLANDK (XQEJLANDK) is a specialized valve assembly designed for efficiently charging an accumulator using a fixed displacement pump. This assembly integrates a ventable priority flow control valve that optimizes pump flow distribution. When the system pressure reaches the preset level, the priority flow control valve vents, allowing all pump flow to be available to the system. Conversely, when pressure drops according to a fixed percentage of the pilot valve, it redirects priority flow for recharging the accumulator, while leaving remaining pump flow accessible to the system. Notable features include a circuit that softens pump unloading and an overpressure relief mechanism to safeguard against excessive pressures. For optimal application, ensure a separate drain line is installed to prevent erratic operation from tank line pressure fluctuations. Selection of an appropriate adjustment range is crucial as system pressure drops and flows can affect unloading valve performance. Low operating pressures with narrow differentials necessitate precise design due to minimal unload-reset bands, while high flow rates induce significant pressure drops affecting differential management. The assembly's porting is intentionally large relative to its capacity, promoting large piping use to minimize issues from flow-induced pressure drops. The spool design of the pilot valve maintains a consistent differential ratio by utilizing non-wearing diameters on the spool. It\u2019s important that accumulator pilot valves are set below any system-side reliefs to avoid severe heating issues. This package's relief feature functions as an overpressure device set higher than any pilot valve setting and remains capped for safety assurance. The Sun Hydraulics XQEJLANDK is capable of handling capacities up to 15 gpm (60 L/min) and employs a line mount body type with specific mounting hole dimensions for secure installation.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
Capacity | 15 gpm60 L/min. |
Body Type | Line mountLine mount |
Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
Mounting Hole Depth | .88 in.22,4 mm |
Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.