You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQEJLANCW


$808.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQEJLANCW
  • Model:XQEJ-LAN-CW
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANCW (XQEJLANCW) is a versatile valve assembly designed for efficiently charging an accumulator using a fixed displacement pump. It features a ventable priority flow control valve that optimizes the flow distribution between the accumulator and the system. When the system pressure reaches a predetermined set point, the priority flow control is vented, allowing full pump flow to be utilized by the system. Conversely, when pressure decreases to a specific level set by the pilot valve's fixed percentage, priority flow is directed to recharge the accumulator while maintaining system operation with available pump flow. This assembly includes additional functionalities such as softening pump unloading and providing overpressure relief to safeguard against excessive pressure. For optimal performance, this assembly requires a separate drain line to mitigate erratic operations caused by tank line pressure variations. Careful selection of adjustment ranges is crucial due to potential impacts on unloading valve operations from system pressure drops and flows. The valve maintains a fixed differential ratio through its spool design, ensuring consistent performance without wear-related changes. The porting size is intentionally large relative to its capacity, promoting use of larger piping to reduce issues from flow-induced pressure drops. The assembly's capacity stands at 15 gpm (60 L/min), and it features a line mount body type with two mounting holes threaded at .375-16 UNC 2B in., each with a depth of .88 inches (22.4 mm). The overpressure relief component is preset higher than any pilot valve setting and capped for safety. This product must be used within specified parameters for maximum effectiveness and safety in hydraulic systems.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity15 gpm60 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.88 in.22,4 mm
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.