SUN HYDRAULICS
XQEJLANBW
$808.40 USD
Tags:
- SUN HYDRAULICS
- Material:XQEJLANBW
- Model:XQEJ-LAN-BW
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANBW (Material Number: XQEJLANBW) is a specialized valve assembly designed for efficiently charging an accumulator with the use of a fixed displacement pump. This assembly features a ventable priority flow control valve, which intelligently manages pump flow based on system pressure demands. When the pressure reaches a predetermined set point, the priority flow control valve vents, allowing full pump flow to be directed to the system. Conversely, when pressure drops to a specific level determined by the pilot valve's fixed percentage, the assembly redirects only the priority flow to recharge the accumulator, while maintaining available pump flow for other system needs. This product includes additional functionalities such as a circuit that softens pump unloading and an overpressure relief system. It requires a separate drain line for optimal operation to avoid erratic behavior due to tank line pressure fluctuations. The assembly's design considerations emphasize selecting an appropriate adjustment range due to potential impacts from system pressure drops and flows on unloading valves' performance. The porting is intentionally large relative to its capacity, encouraging large piping usage to minimize issues from flow-induced pressure drops. The spool design of its pilot valve ensures consistent differential ratio maintenance by utilizing diameters that resist wear over time. It's crucial that the accumulator pilot valve is adjusted below any reliefs within the pump side of the system to prevent overheating. Additionally, while this package includes an overpressure relief feature set higher than the pilot valve's highest setting, it serves primarily as an emergency measure rather than regular operational control.
The Sun Hydraulics XQEJLANBW (Material Number: XQEJLANBW) is a specialized valve assembly designed for efficiently charging an accumulator with the use of a fixed displacement pump. This assembly features a ventable priority flow control valve, which intelligently manages pump flow based on system pressure demands. When the pressure reaches a predetermined set point, the priority flow control valve vents, allowing full pump flow to be directed to the system. Conversely, when pressure drops to a specific level determined by the pilot valve's fixed percentage, the assembly redirects only the priority flow to recharge the accumulator, while maintaining available pump flow for other system needs. This product includes additional functionalities such as a circuit that softens pump unloading and an overpressure relief system. It requires a separate drain line for optimal operation to avoid erratic behavior due to tank line pressure fluctuations. The assembly's design considerations emphasize selecting an appropriate adjustment range due to potential impacts from system pressure drops and flows on unloading valves' performance. The porting is intentionally large relative to its capacity, encouraging large piping usage to minimize issues from flow-induced pressure drops. The spool design of its pilot valve ensures consistent differential ratio maintenance by utilizing diameters that resist wear over time. It's crucial that the accumulator pilot valve is adjusted below any reliefs within the pump side of the system to prevent overheating. Additionally, while this package includes an overpressure relief feature set higher than the pilot valve's highest setting, it serves primarily as an emergency measure rather than regular operational control.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
Capacity | 15 gpm60 L/min. |
Body Type | Line mountLine mount |
Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
Mounting Hole Depth | .88 in.22,4 mm |
Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.