SUN HYDRAULICS
XQEJLANBV
$808.40 USD
Tags:
- SUN HYDRAULICS
- Material:XQEJLANBV
- Model:XQEJ-LAN-BV
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANBV (XQEJLANBV) is a sophisticated valve assembly designed to efficiently manage accumulator charging using a fixed displacement pump. It features an innovative ventable priority flow control valve, which allows for optimal system performance by directing pump flow based on pressure conditions. When the system pressure reaches the valve's set point, the priority flow control vents, allowing full pump flow to be utilized by the system. Conversely, when pressure falls to a predetermined level set by the pilot valve's fixed percentage, only the priority flow recharges the accumulator, leaving additional pump capacity for other system needs. This assembly includes a circuit for soft unloading of pumps and an overpressure relief mechanism to enhance safety and functionality. For effective operation, it is crucial to implement a separate drain line to mitigate erratic behavior due to tank line pressure fluctuations. The assembly's design requires careful selection of adjustment ranges due to potential impacts from system pressure drops and flows on unloading valves. High flow rates can lead to significant pressure drops, affecting differential pressures necessary for proper valve operation. Notably, the assembly is engineered with large porting relative to its capacity, promoting use of large piping that minimizes issues from flow-induced pressure drops. The pilot valve's spool design ensures consistent differential ratio maintenance over time by utilizing diameters that resist wear and change. It is essential that the accumulator pilot valve be set below any reliefs on the pump side of the system to prevent excessive heating. The integrated relief device serves as an overpressure safeguard and is preset higher than any pilot valve settings before being capped. This line-mounted assembly has a capacity of 15 gpm (60 L/min) and requires .375-16 UNC 2B mounting holes with a depth of .88 inches (22.4 mm), necessitating precise installation considerations for optimal performance in hydraulic systems.
The Sun Hydraulics XQEJLANBV (XQEJLANBV) is a sophisticated valve assembly designed to efficiently manage accumulator charging using a fixed displacement pump. It features an innovative ventable priority flow control valve, which allows for optimal system performance by directing pump flow based on pressure conditions. When the system pressure reaches the valve's set point, the priority flow control vents, allowing full pump flow to be utilized by the system. Conversely, when pressure falls to a predetermined level set by the pilot valve's fixed percentage, only the priority flow recharges the accumulator, leaving additional pump capacity for other system needs. This assembly includes a circuit for soft unloading of pumps and an overpressure relief mechanism to enhance safety and functionality. For effective operation, it is crucial to implement a separate drain line to mitigate erratic behavior due to tank line pressure fluctuations. The assembly's design requires careful selection of adjustment ranges due to potential impacts from system pressure drops and flows on unloading valves. High flow rates can lead to significant pressure drops, affecting differential pressures necessary for proper valve operation. Notably, the assembly is engineered with large porting relative to its capacity, promoting use of large piping that minimizes issues from flow-induced pressure drops. The pilot valve's spool design ensures consistent differential ratio maintenance over time by utilizing diameters that resist wear and change. It is essential that the accumulator pilot valve be set below any reliefs on the pump side of the system to prevent excessive heating. The integrated relief device serves as an overpressure safeguard and is preset higher than any pilot valve settings before being capped. This line-mounted assembly has a capacity of 15 gpm (60 L/min) and requires .375-16 UNC 2B mounting holes with a depth of .88 inches (22.4 mm), necessitating precise installation considerations for optimal performance in hydraulic systems.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
Capacity | 15 gpm60 L/min. |
Body Type | Line mountLine mount |
Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
Mounting Hole Depth | .88 in.22,4 mm |
Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.