***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANBL (XQEJLANBL) is a sophisticated valve assembly designed to efficiently charge accumulators using a fixed displacement pump. This assembly features a ventable priority flow control valve, which optimizes system performance by redirecting all pump flow to the system once the set pressure is achieved. When pressure decreases to a predetermined level, the priority flow recharges the accumulator while maintaining system efficiency. The assembly includes a circuit that softens pump unloading and an overpressure relief mechanism for enhanced safety. To ensure optimal operation, it is crucial to incorporate a separate drain line to mitigate erratic behavior caused by tank line pressure fluctuations. Selecting an appropriate adjustment range is vital, as low operating pressures and differentials can create narrow bands between unload and reset points, necessitating precise system design. High flow rates may lead to increased pressure drops, affecting valve operation. The XQEJLANBL's porting is intentionally large relative to its capacity, encouraging the use of large piping to minimize issues related to flow-induced pressure drops. The pilot valve's spool design maintains a consistent differential ratio due to its durable construction, ensuring reliable performance over time. It's important that the accumulator pilot valve is set below any reliefs in the pump side of the system to prevent excessive heating. This assembly has a capacity of 15 gpm (60 L/min) and is designed for line mount applications with .375-16 UNC 2B mounting hole threads and .88-inch depth. Additionally, this package includes an overpressure relief device set higher than the pilot valve's maximum setting for added protection.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity15 gpm60 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.88 in.22,4 mm
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.