***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANAV (XQEJLANAV) is a sophisticated valve assembly designed specifically for charging accumulators using a fixed displacement pump. A key component of this assembly is the ventable priority flow control valve, which efficiently manages system pressure by venting when the set point is reached, thereby redirecting all pump flow to the system. As pressure decreases to a predetermined level, the priority flow recharges the accumulator while maintaining system availability with the remaining pump flow. This assembly integrates additional features such as a circuit for soft pump unloading and an overpressure relief system to enhance operational safety and efficiency. A critical aspect of utilizing this valve assembly is ensuring a separate drain line to mitigate erratic operation due to tank line pressure fluctuations. The design considerations include selecting an appropriate adjustment range, as low operating pressures paired with minimal differentials can lead to narrow bands between unloading and resetting, necessitating precise system design. Additionally, high flow rates may result in significant pressure drops affecting the differential available for valve operation. The XQEJLANAV's pilot valve spool design ensures consistent differential ratios by utilizing non-wearing spool diameters. It\u2019s crucial that the accumulator pilot valve setting remains below any reliefs on the pump side to prevent excessive heating. This package's relief feature acts as an overpressure safeguard, preset above the highest pilot valve setting and capped for security. With a capacity of 15 gpm (60 L/min), this line-mount body type assembly requires careful attention to port sizing relative to capacity, encouraging large piping use to minimize flow-induced pressure drops. The robust construction supports efficient hydraulic management in systems requiring precise accumulator charging control.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity15 gpm60 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.88 in.22,4 mm
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.