You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQEJLANAD


$823.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQEJLANAD
  • Model:XQEJ-LAN-AD
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEJLANAD (Material Number: XQEJLANAD) is a specialized valve assembly designed for charging an accumulator using a fixed displacement pump. This assembly features a ventable priority flow control valve that optimizes pump flow management. When the system pressure reaches the set point, the priority flow control is vented, allowing the entire pump flow to be directed to the system. Conversely, when pressure drops to a predetermined level set by the pilot valve, only the priority flow is used to recharge the accumulator, ensuring efficient use of resources by leaving additional pump flow available for other system needs. This assembly includes two key features: a circuit that softens pump unloading and an overpressure relief mechanism for added safety. For optimal performance, it requires a separate drain line to prevent erratic operations due to tank line pressure fluctuations. The pressure setting and reseat pressure are based on the port 2 area of the QCD pilot valve, with adjustments necessary for precise system design due to operating conditions affecting unloading valves. It is important to note that this assembly's large porting encourages using appropriately sized piping to minimize issues related to flow-induced pressure drops. Additionally, its spool design maintains a fixed differential ratio due to durable spool diameters that resist wear over time. The relief mechanism in this package serves as an overpressure device set higher than the pilot valve's highest setting and is capped for security. With a capacity of 15 gpm (60 L/min) and designed for line mounting with .375-16 UNC 2B threaded mounting holes, this assembly provides reliable performance in managing hydraulic systems efficiently and safely.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has two additional features; a simple circuit that softens the unloading of the pump and a system over-pressure relief.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity15 gpm60 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.88 in.22,4 mm
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.