***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEHLANDX (Material Number: XQEHLANDX) is a sophisticated valve assembly designed for charging an accumulator using a fixed displacement pump. It operates by unloading the pump when the pressure reaches a predetermined set point and re-engaging it when the pressure drops to a level set by the pilot valve. This dual-purpose system not only unloads the pump but also acts as an overpressure relief mechanism. Notably, it features a circuit that softens pump unloading and allows for remote sensing of accumulator pressure, enhancing its versatility and efficiency in hydraulic systems. For optimal performance, a separate drain line is necessary to avoid erratic operations from tank line pressure fluctuations. The assembly requires careful adjustment range selection due to potential impacts on unloading valve operation from system pressure drops and flows. A narrow band between unload and reset pressures demands precise system design, especially at low operating pressures with low differentials. High flow rates can lead to significant pressure drops, affecting the valve's differential range. The assembly's porting is intentionally large relative to its capacity, promoting the use of large piping to mitigate flow-induced pressure drops. The spool design of the pilot valve maintains a fixed differential ratio, ensuring consistent performance over time as wear does not alter the spool diameters. Additionally, it's crucial that the accumulator pilot valve is set below any reliefs on the pump side to prevent excessive heating. This assembly supports up to 20 gpm (80 L/min) flow rates and features line mount body type with through-hole mounting capabilities. Its robust design makes it suitable for demanding hydraulic applications where precise control of accumulator charging is essential.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.